FULL LUMEN INFANT BRONCHOSCOPE

FULL LUMEN INFANT BRONCHOSCOPE Abstract Jesberg1 stated in 1941 that the bronchoscopic examination of young infants presents an unusual risk because of the anatomically small glottis and subglottis. The hazard is further increased by inflammatory swelling of these regions. He further stated that the then existing bronchoscopes fit the glottis too snugly and often could not be passed without force. Accordingly, he and, a short time later, Holinger2 developed distally lighted bronchoscopes of smaller outside diameter which, nevertheless, preserved a good working lumen. The development of both instruments was dependent on a smaller bulb, and both men used light carriers. The instrument described here has an even larger lumen, owing to the elimination of the light carrier. Instead, two insulated "hair wires" are buried in the wall of the bronchoscope tube so that they do not project either to the inside or to the outside (fig. 1). Two distally placed "grain of wheat" lamps References 1. Jesberg, S.: Baby Bronchoscopes , Arch. Otolaryng. 33:88-89 ( (Jan.) ) 1941.Crossref 2. Holinger, P.: New Infant Bronchoscope and Esophagoscope , Arch. Otolaryng. 33:431-432 ( (March) ) 1941.Crossref http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png A.M.A. Archives of Otolaryngology American Medical Association

FULL LUMEN INFANT BRONCHOSCOPE

A.M.A. Archives of Otolaryngology , Volume 53 (1) – Jan 1, 1951

Loading next page...
 
/lp/american-medical-association/full-lumen-infant-bronchoscope-TLZuDZCxvI
Publisher
American Medical Association
Copyright
Copyright © 1951 American Medical Association. All Rights Reserved.
ISSN
0096-6894
DOI
10.1001/archotol.1951.03750010112011
Publisher site
See Article on Publisher Site

Abstract

Abstract Jesberg1 stated in 1941 that the bronchoscopic examination of young infants presents an unusual risk because of the anatomically small glottis and subglottis. The hazard is further increased by inflammatory swelling of these regions. He further stated that the then existing bronchoscopes fit the glottis too snugly and often could not be passed without force. Accordingly, he and, a short time later, Holinger2 developed distally lighted bronchoscopes of smaller outside diameter which, nevertheless, preserved a good working lumen. The development of both instruments was dependent on a smaller bulb, and both men used light carriers. The instrument described here has an even larger lumen, owing to the elimination of the light carrier. Instead, two insulated "hair wires" are buried in the wall of the bronchoscope tube so that they do not project either to the inside or to the outside (fig. 1). Two distally placed "grain of wheat" lamps References 1. Jesberg, S.: Baby Bronchoscopes , Arch. Otolaryng. 33:88-89 ( (Jan.) ) 1941.Crossref 2. Holinger, P.: New Infant Bronchoscope and Esophagoscope , Arch. Otolaryng. 33:431-432 ( (March) ) 1941.Crossref

Journal

A.M.A. Archives of OtolaryngologyAmerican Medical Association

Published: Jan 1, 1951

References