Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You and Your Team.

Learn More →

Femorofemoral Bypass Graft in Intra-aortic Balloon Counterpulsation

Femorofemoral Bypass Graft in Intra-aortic Balloon Counterpulsation Abstract • Femorofemoral arterial crossover grafts were used in three patients to avoid or correct limb ischemia during intra-aortic balloon counterpulsation. In retrospect, these grafts should have been used in two earlier patients in whom the balloon was removed prematurely. They are applied to the femoral artery just distal to the site of insertion of the balloon or to the balloon access graft. Removal of the graft at the time of the balloon removal is optional. (Arch Surg 111:1070-1072, 1976) References 1. Vetto RM: The treatment of unilateral iliac artery obstruction with a transabdominal, subcutaneous, femoro-femoral graft . Surgery 52:342-345, 1962. 2. Vetto RM: The femoro-femoral shunt: An appraisal . Am J Surg 112:162-165, 1966.Crossref 3. Brief DK, Alpert J, Parsonnet V: Crossover femoro-femoral grafts . Arch Surg 105:889-894, 1972.Crossref 4. Davis RC, O'Hara ET, Mannick JA, et al: Broadened indications for femoro-femoral grafts . Surgery 72:990-994, 1972. 5. Brief DK, Brener BJ, Alpert J, et al: Crossover femorofemoral grafts followed up five years or more: An analysis . Arch Surg 110:1294-1299, 1975.Crossref 6. Warren WD, Fomon JJ: Rerouting arterial flow to relieve ischemia: Femoro-femoral, axillary-femoral and carotid-carotid bypasses . Ann Surg 163:131-136, 1966.Crossref 7. Foley WJ, Dow RW, Fry WJ: Crossover femoro-femoral bypass grafts . Arch Surg 99:83-87, 1969.Crossref 8. Ehrenfeld WR, Harris JP, Wylie EJ: Vascular "steal" phenomenon: An experimental study . Am J Surg 116:192-197, 1968.Crossref 9. Parsonnet V, Alpert J, Brief DK: Femoro-femoral and axillo-femoral grafts: Compromise or preference . Surgery 67:26-33, 1970. 10. Sumner DS, Strandness DE Jr: The hemodynamics of the femoro-femoral shunt . Surg Gynecol Obstet 134:629-636, 1972. 11. Weber KT, Janicki JS: Intra-aortic balloon counterpulsation: Collective review . Ann Thorac Surg 17:602-636, 1974.Crossref 12. Scheidt S, Wilner G, Mueller H, et al: Intra-aortic balloon counterpulsation in cardiogenic shock: Report of a co-operative clinical trial . N Engl J Med 288:979-984, 1973.Crossref 13. Burman SO: Intra-aortic balloon pumping for low cardiac output syndromes . Surg Clin North Am 55:101-106, 1975. 14. Cleveland JC, Lefemine AA, Madoff I, et al: The role of intra-aortic balloon counterpulsation in patients undergoing cardiac operations . Ann Thorac Surg 20:652-660, 1975.Crossref 15. Dunkmann W, Leimbach RC, Buckley MJ, et al: Clinical and hemodynamic results of intra-aortic balloon pumping and surgery for cardiogenic shock . Circulation 46:465-477, 1972.Crossref 16. Saini VK, Berger RL: Technique of aortic balloon catheter deployment with the use of a Fogarty catheter . Ann Thorac Surg 14:440-442, 1972.Crossref 17. Printup CA Jr, Dietrick WR, Getzen JH, et al: Ascending aorta insertion of the dual-chambered intraaortic balloon for counterpulsation during cardiac operations . Ann Thorac Surg 20:694-697, 1975.Crossref 18. Krause AH, in discussion, Cleveland JC, Lefemine AA, Madoff I, et al: The role of intra-aortic balloon counterpulsation in patients undergoing cardiac operations . Ann Thorac Surg 20:652-659, 1975.Crossref 19. Blaisdell FW, Hall AD: Axillary femoral artery bypass for lower extremity ischemia . Surgery 54:563-568, 1963. 20. Mannick JA, Nabseth DA: Axillo-femoral bypass graft: A safe alternative to aorto-iliac reconstruction . N Engl J Med 278:461-466, 1968.Crossref http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Archives of Surgery American Medical Association

Loading next page...
 
/lp/american-medical-association/femorofemoral-bypass-graft-in-intra-aortic-balloon-counterpulsation-bkSQF0SaG6
Publisher
American Medical Association
Copyright
Copyright © 1976 American Medical Association. All Rights Reserved.
ISSN
0004-0010
eISSN
1538-3644
DOI
10.1001/archsurg.1976.01360280028004
Publisher site
See Article on Publisher Site

Abstract

Abstract • Femorofemoral arterial crossover grafts were used in three patients to avoid or correct limb ischemia during intra-aortic balloon counterpulsation. In retrospect, these grafts should have been used in two earlier patients in whom the balloon was removed prematurely. They are applied to the femoral artery just distal to the site of insertion of the balloon or to the balloon access graft. Removal of the graft at the time of the balloon removal is optional. (Arch Surg 111:1070-1072, 1976) References 1. Vetto RM: The treatment of unilateral iliac artery obstruction with a transabdominal, subcutaneous, femoro-femoral graft . Surgery 52:342-345, 1962. 2. Vetto RM: The femoro-femoral shunt: An appraisal . Am J Surg 112:162-165, 1966.Crossref 3. Brief DK, Alpert J, Parsonnet V: Crossover femoro-femoral grafts . Arch Surg 105:889-894, 1972.Crossref 4. Davis RC, O'Hara ET, Mannick JA, et al: Broadened indications for femoro-femoral grafts . Surgery 72:990-994, 1972. 5. Brief DK, Brener BJ, Alpert J, et al: Crossover femorofemoral grafts followed up five years or more: An analysis . Arch Surg 110:1294-1299, 1975.Crossref 6. Warren WD, Fomon JJ: Rerouting arterial flow to relieve ischemia: Femoro-femoral, axillary-femoral and carotid-carotid bypasses . Ann Surg 163:131-136, 1966.Crossref 7. Foley WJ, Dow RW, Fry WJ: Crossover femoro-femoral bypass grafts . Arch Surg 99:83-87, 1969.Crossref 8. Ehrenfeld WR, Harris JP, Wylie EJ: Vascular "steal" phenomenon: An experimental study . Am J Surg 116:192-197, 1968.Crossref 9. Parsonnet V, Alpert J, Brief DK: Femoro-femoral and axillo-femoral grafts: Compromise or preference . Surgery 67:26-33, 1970. 10. Sumner DS, Strandness DE Jr: The hemodynamics of the femoro-femoral shunt . Surg Gynecol Obstet 134:629-636, 1972. 11. Weber KT, Janicki JS: Intra-aortic balloon counterpulsation: Collective review . Ann Thorac Surg 17:602-636, 1974.Crossref 12. Scheidt S, Wilner G, Mueller H, et al: Intra-aortic balloon counterpulsation in cardiogenic shock: Report of a co-operative clinical trial . N Engl J Med 288:979-984, 1973.Crossref 13. Burman SO: Intra-aortic balloon pumping for low cardiac output syndromes . Surg Clin North Am 55:101-106, 1975. 14. Cleveland JC, Lefemine AA, Madoff I, et al: The role of intra-aortic balloon counterpulsation in patients undergoing cardiac operations . Ann Thorac Surg 20:652-660, 1975.Crossref 15. Dunkmann W, Leimbach RC, Buckley MJ, et al: Clinical and hemodynamic results of intra-aortic balloon pumping and surgery for cardiogenic shock . Circulation 46:465-477, 1972.Crossref 16. Saini VK, Berger RL: Technique of aortic balloon catheter deployment with the use of a Fogarty catheter . Ann Thorac Surg 14:440-442, 1972.Crossref 17. Printup CA Jr, Dietrick WR, Getzen JH, et al: Ascending aorta insertion of the dual-chambered intraaortic balloon for counterpulsation during cardiac operations . Ann Thorac Surg 20:694-697, 1975.Crossref 18. Krause AH, in discussion, Cleveland JC, Lefemine AA, Madoff I, et al: The role of intra-aortic balloon counterpulsation in patients undergoing cardiac operations . Ann Thorac Surg 20:652-659, 1975.Crossref 19. Blaisdell FW, Hall AD: Axillary femoral artery bypass for lower extremity ischemia . Surgery 54:563-568, 1963. 20. Mannick JA, Nabseth DA: Axillo-femoral bypass graft: A safe alternative to aorto-iliac reconstruction . N Engl J Med 278:461-466, 1968.Crossref

Journal

Archives of SurgeryAmerican Medical Association

Published: Oct 1, 1976

References