Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography

Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography ImportanceMammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results. ObjectiveTo determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. Design, Setting, and ParticipantsRetrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. ExposuresPeriod 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. Main Outcomes and MeasuresRecall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy. ResultsA total of 454 850 examinations (n=281 187 digital mammography; n=173 663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29 726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n=815 invasive; n=392 in situ). With digital mammography + tomosynthesis, 15 541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n=707 invasive; n=243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, –16 (95% CI, –18 to –14; P < .001); for biopsies, 18.1 (95% CI, 15.4-20.8) with digital mammography vs 19.3 (95% CI, 16.6-22.1) with digital mammography + tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001); and for invasive cancer detection, 2.9 (95% CI, 2.5-3.2) with digital mammography vs 4.1 (95% CI, 3.7-4.5) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001). The in situ cancer detection rate was 1.4 (95% CI, 1.2-1.6) per 1000 screens with both methods. Adding tomosynthesis was associated with an increase in the positive predictive value for recall from 4.3% to 6.4% (difference, 2.1%; 95% CI, 1.7%-2.5%; P < .001) and for biopsy from 24.2% to 29.2% (difference, 5.0%; 95% CI, 3.0%-7.0%; P < .001). Conclusions and RelevanceAddition of tomosynthesis to digital mammography was associated with a decrease in recall rate and an increase in cancer detection rate. Further studies are needed to assess the relationship to clinical outcomes. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png JAMA American Medical Association

Loading next page...
 
/lp/american-medical-association/breast-cancer-screening-using-tomosynthesis-in-combination-with-vi2HIkArMW
Publisher
American Medical Association
Copyright
Copyright 2014 American Medical Association. All Rights Reserved. Applicable FARS/DFARS Restrictions Apply to Government Use.
ISSN
0098-7484
eISSN
1538-3598
DOI
10.1001/jama.2014.6095
pmid
25058084
Publisher site
See Article on Publisher Site

Abstract

ImportanceMammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results. ObjectiveTo determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. Design, Setting, and ParticipantsRetrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. ExposuresPeriod 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. Main Outcomes and MeasuresRecall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy. ResultsA total of 454 850 examinations (n=281 187 digital mammography; n=173 663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29 726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n=815 invasive; n=392 in situ). With digital mammography + tomosynthesis, 15 541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n=707 invasive; n=243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, –16 (95% CI, –18 to –14; P < .001); for biopsies, 18.1 (95% CI, 15.4-20.8) with digital mammography vs 19.3 (95% CI, 16.6-22.1) with digital mammography + tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001); and for invasive cancer detection, 2.9 (95% CI, 2.5-3.2) with digital mammography vs 4.1 (95% CI, 3.7-4.5) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P < .001). The in situ cancer detection rate was 1.4 (95% CI, 1.2-1.6) per 1000 screens with both methods. Adding tomosynthesis was associated with an increase in the positive predictive value for recall from 4.3% to 6.4% (difference, 2.1%; 95% CI, 1.7%-2.5%; P < .001) and for biopsy from 24.2% to 29.2% (difference, 5.0%; 95% CI, 3.0%-7.0%; P < .001). Conclusions and RelevanceAddition of tomosynthesis to digital mammography was associated with a decrease in recall rate and an increase in cancer detection rate. Further studies are needed to assess the relationship to clinical outcomes.

Journal

JAMAAmerican Medical Association

Published: Jun 25, 2014