Access the full text.
Sign up today, get DeepDyve free for 14 days.
T. Becske, D. Kallmes, I. Saatci, C. McDougall, I. Szikora, G. Lanzino, C. Moran, H. Woo, D. Lopes, A. Berez, D. Cher, A. Siddiqui, E. Levy, F. Albuquerque, D. Fiorella, Z. Berentei, M. Marosfoi, S. Cekirge, P. Nelson (2013)
Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial.Radiology, 267 3
W. Brinjikji, MH. Murad, G. Lanzino (2013)
Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysisStroke, 44
DF. Kallmes, R. Hanel, D. Lopes (2015)
International retrospective study of the Pipeline embolization device: a multicenter aneurysm treatment studyAJNR Am J Neuroradiol, 36
D. Kallmes, W. Brinjikji, E. Boccardi, E. Ciceri, O. Diaz, R. Tawk, H. Woo, P. Jabbour, F. Albuquerque, R. Chapot, A. Bonafe, S. Dashti, J. Almandoz, Curtis Given, M. Kelly, D. Cross, G. Duckwiler, N. Razack, C. Powers, S. Fischer, D. Lopes, M. Harrigan, D. Huddle, Raymond Turner, O. Zaidat, L. Defreyne, V. Pereira, S. Cekirge, D. Fiorella, R. Hanel, P. Lylyk, C. McDougall, A. Siddiqui, I. Szikora, E. Levy (2016)
Aneurysm Study of Pipeline in an Observational Registry (ASPIRe).Interventional neurology, 5 1-2
MA. Mohlenbruch, C. Herweh, L. Jestaedt (2015)
The FRED flow-diverter stent for intracranial aneurysms: clinical study to assess safety and efficacyAJNR Am J Neuroradiol, 36
D. Vollherbst, H. Cekirge, I. Saatci, F. Baltacıoğlu, B. Onal, O. Koc, R. Rautio, M. Sinisalo, A. Tomasello, P. Vega, M. Martínez‐Galdámez, J. Lynch, V. Pereira, M. Bendszus, M. Möhlenbruch (2022)
First clinical multicenter experience with the new Pipeline Vantage flow diverterJournal of NeuroInterventional Surgery, 15
Bernadette Nutter, A. Stammers, Ryan Schmer, R. Ahlgren, Tunisia Ellis, Chen Gao, Hunter Holcomb, L. Hock, Tab Burkeman (2004)
The Rheological Effects of X-Coating™ with Albumin and Hetastarch on Blood during Cardiopulmonary BypassThe Journal of ExtraCorporeal Technology
X. Lv, Hongchao Yang, Peng Liu, Youxiang Li (2016)
Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic reviewThe Neuroradiology Journal, 29
J. Fiehler, T. Ries (2009)
Prevention and Treatment of Thromboembolism during Endovascular Aneurysm Therapy*Clinical Neuroradiology, 19
S. Skukalek, A. Winkler, Jian Kang, J. Dion, C. Cawley, Adam Webb, Mark Dannenbaum, A. Schuette, B. Asbury, F. Tong (2014)
Effect of antiplatelet therapy and platelet function testing on hemorrhagic and thrombotic complications in patients with cerebral aneurysms treated with the pipeline embolization device: a review and meta-analysisJournal of NeuroInterventional Surgery, 8
Y. Ihn, S. Shin, S. Baik, I. Choi (2018)
Complications of endovascular treatment for intracranial aneurysms: Management and preventionInterventional Neuroradiology, 24
T. Becske, W. Brinjikji, M. Potts, D. Kallmes, M. Shapiro, C. Moran, E. Levy, C. McDougall, I. Szikora, G. Lanzino, H. Woo, D. Lopes, A. Siddiqui, F. Albuquerque, D. Fiorella, I. Saatci, S. Cekirge, A. Berez, D. Cher, Z. Berentei, M. Marosfoi, P. Nelson (2017)
Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms TrialNeurosurgery, 80
C. O'Kelly, Timo Krings, D. Fiorella, T. Marotta (2010)
A Novel Grading Scale for the Angiographic Assessment of Intracranial Aneurysms Treated Using Flow Diverting StentsInterventional Neuroradiology, 16
MA. Mohlenbruch, O. Kizilkilic, M. Killer-Oberpfalzer (2017)
Multicenter experience with FRED Jr Flow Re-Direction Endoluminal Device for intracranial aneurysms in small arteriesAJNR Am J Neuroradiol, 38
L. Pierot, L. Spelle, J. Berge, A. Januel, D. Herbreteau, M. Aggour, M. Piotin, A. Biondi, X. Barreau, C. Mounayer, C. Papagiannaki, J. Lejeune, J. Gauvrit, A. Derelle, E. Chabert, V. Costalat (2018)
SAFE study (Safety and efficacy Analysis of FRED Embolic device in aneurysm treatment): 1-year clinical and anatomical resultsJournal of Neurointerventional Surgery, 11
S. Gunaydin, B. Farsak, M. Kocakulak (2002)
Clinical performance and biocompatibility of poly(2-methoxyethylacrylate)--coated extracorporeal circuitsThe Annals of Thoracic Surgery, 74
M. Marosfoi, F. Clarençon, E. Langan, R. King, O. Brooks, T. Tamura, J. Wainwright, M. Gounis, S. Vedantham, A. Puri (2017)
Acute thrombus formation on phosphorilcholine surface modified flow divertersJournal of Neurointerventional Surgery, 10
C. McDougall, O. Diaz, A. Boulos, A. Siddiqui, J. Caplan, J. Fifi, A. Turk, Y. Kayan, P. Jabbour, L. Kim, S. Hetts, D. Cooke, C. Dowd (2021)
Safety and efficacy results of the Flow Redirection Endoluminal Device (FRED) stent system in the treatment of intracranial aneurysms: US pivotal trialJournal of Neurointerventional Surgery, 14
R. King, E. Langan, G. Ughi, C. Raskett, A. Puri, H. Henkes, M. Gounis (2020)
Acute Thrombus Burden on Coated Flow Diverters Assessed by High Frequency Optical Coherence TomographyCardioVascular and Interventional Radiology
J. Mascitelli, H. Moyle, E. Oermann, M. Polykarpou, Aanand Patel, A. Doshi, Y. Gologorsky, J. Bederson, A. Patel (2014)
An update to the Raymond–Roy Occlusion Classification of intracranial aneurysms treated with coil embolizationJournal of NeuroInterventional Surgery, 7
M. Killer-Oberpfalzer, N. Kocer, CJ. Griessenauer (2018)
European multicenter study for the evaluation of a dual-layer flow-diverting stent for treatment of wide-neck intracranial aneurysms: the European Flow-Redirection Intraluminal Device StudyAJNR Am J Neuroradiol, 39
BACKGROUND AND PURPOSE: Flow diverters with antithrombotic coatings are increasingly used to improve the safety of flow diverter treatments of intracranial aneurysms. This study aimed to investigate the safety and short-term efficacy of the new FRED X flow diverter. MATERIALS AND METHODS: Medical charts and procedural and imaging data of a consecutive series of patients with intracranial aneurysms who were treated with the FRED X at 9 international neurovascular centers were retrospectively analyzed. RESULTS: One hundred sixty-one patients (77.6% women; mean age, 55 years) with 184 aneurysms (11.2% acutely ruptured) were included in this study. Most aneurysms were located in the anterior circulation (77.0%), most frequently at the ICA (72.7%). The FRED X was successfully implanted in all procedures. Additional coiling was performed in 29.8%. In-stent balloon angioplasty was necessary in 2.5%. The rate of major adverse events was 3.1%. Thrombotic events occurred in 7 patients (4.3%) with 4 intra- and 4 postprocedural in-stent thromboses, respectively (1 patient had both peri- and postprocedural thrombosis). Of these thrombotic events, only 2 (1.2%) led to major adverse events (ischemic strokes). Postinterventional neurologic morbidity and mortality were observed in 1.9% and 1.2%, respectively. The rate of complete aneurysm occlusion after a mean follow-up of 7.0 months was 66.0%. CONCLUSIONS: The new FRED X is a safe and feasible device for aneurysm treatment. In this retrospective multicenter study, the rate of thrombotic complications was low, and the short-term occlusion rates are satisfactory.
American Journal of Neuroradiology – American Journal of Neuroradiology
Published: Apr 1, 2023
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.