Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Small Pipes: Preliminary Experience with 3-mm or Smaller Pipeline Flow-Diverting Stents for Aneurysm Repair prior to Regulatory Approval

Small Pipes: Preliminary Experience with 3-mm or Smaller Pipeline Flow-Diverting Stents for... SUMMARY: Flow diversion has become an established treatment option for challenging intracranial aneurysms. The use of small devices of ≤3-mm diameter remains unapproved by major regulatory bodies. A retrospective review of patients treated with Pipeline Embolization Devices of ≤3-mm diameter at 3 Canadian institutions was conducted. Clinical and radiologic follow-up data were collected and reported. Twelve cases were treated with ≥1 Pipeline Embolization Device of ≤3-mm diameter, including 2 with adjunctive coiling, with a median follow-up of 18 months (range, 4–42 months). One patient experienced a posttreatment minor complication (8%) due to an embolic infarct. No posttreatment hemorrhage or delayed complications such as in-stent stenosis/thrombosis were observed. Radiologic occlusion was seen in 9/12 cases (75%) and near-occlusion in 2/12 cases (17%). Intracranial aneurysm treatment with small-diameter flow-diverting stents provided safe and effective aneurysm closure in this small selected sample. These devices should be further studied and considered for regulatory approval. ABBREVIATIONS: PED Pipeline Embolization Device PICA posterior inferior cerebellar artery http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png American Journal of Neuroradiology American Journal of Neuroradiology

Small Pipes: Preliminary Experience with 3-mm or Smaller Pipeline Flow-Diverting Stents for Aneurysm Repair prior to Regulatory Approval

Loading next page...
 
/lp/american-journal-of-neuroradiology/small-pipes-preliminary-experience-with-3-mm-or-smaller-pipeline-flow-wxanEOrQ0x
Publisher
American Journal of Neuroradiology
Copyright
Copyright © 2015 by the American Society of Neuroradiology.
ISSN
0195-6108
eISSN
1936-959X
DOI
10.3174/ajnr.A4170
pmid
25395659
Publisher site
See Article on Publisher Site

Abstract

SUMMARY: Flow diversion has become an established treatment option for challenging intracranial aneurysms. The use of small devices of ≤3-mm diameter remains unapproved by major regulatory bodies. A retrospective review of patients treated with Pipeline Embolization Devices of ≤3-mm diameter at 3 Canadian institutions was conducted. Clinical and radiologic follow-up data were collected and reported. Twelve cases were treated with ≥1 Pipeline Embolization Device of ≤3-mm diameter, including 2 with adjunctive coiling, with a median follow-up of 18 months (range, 4–42 months). One patient experienced a posttreatment minor complication (8%) due to an embolic infarct. No posttreatment hemorrhage or delayed complications such as in-stent stenosis/thrombosis were observed. Radiologic occlusion was seen in 9/12 cases (75%) and near-occlusion in 2/12 cases (17%). Intracranial aneurysm treatment with small-diameter flow-diverting stents provided safe and effective aneurysm closure in this small selected sample. These devices should be further studied and considered for regulatory approval. ABBREVIATIONS: PED Pipeline Embolization Device PICA posterior inferior cerebellar artery

Journal

American Journal of NeuroradiologyAmerican Journal of Neuroradiology

Published: Mar 1, 2015

There are no references for this article.