Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Canadian Experience with the Pipeline Embolization Device for Repair of Unruptured Intracranial Aneurysms

Canadian Experience with the Pipeline Embolization Device for Repair of Unruptured Intracranial... BACKGROUND AND PURPOSE: Flow-diverting stents, such as the PED, have emerged as a novel means of treating complex intracranial aneurysms. This retrospective analysis of the initial Canadian experience provides insight into technical challenges, clinical and radiographic outcomes, and complication rates after the use of flow-diverting stents for unruptured aneurysms. MATERIALS AND METHODS: Cases were compiled from 7 Canadian centers between July 2008 and December 2010. Each center prospectively tracked their initial experience; these data were retrospectively updated and pooled for analysis. RESULTS: During the defined study period, 97 cases of unruptured aneurysm were treated with the PED, with successful stent deployment in 94 cases. The overall complete or near-complete occlusion rate was 83%, with a median follow-up at 1.25 years (range 0.25–2.5 years). Progressive occlusion was witnessed over time, with complete or near-complete occlusion in 65% of aneurysms followed through 6 months, and 90% of aneurysms followed through 1 year. Multivariate analysis found previous aneurysm treatment and female sex predictive of persistent aneurysm filling. Most patients were stable or improved (88%), with the most favorable outcomes observed in patients with cavernous carotid aneurysms. The overall mortality rate was 6%. Postprocedural aneurysm hemorrhage occurred in 3 patients (3%), while ipsilateral distal territory hemorrhage was observed in 4 patients (3.4%). CONCLUSIONS: Flow-diverting stents represent an important tool in the treatment of complex intracranial aneurysms. The relative efficacy and morbidity of this treatment must be considered in the context of available alternate interventions. ABBREVIATIONS: ICH intracerebral hemorrhage PED Pipeline embolization device http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png American Journal of Neuroradiology American Journal of Neuroradiology

Canadian Experience with the Pipeline Embolization Device for Repair of Unruptured Intracranial Aneurysms

Loading next page...
 
/lp/american-journal-of-neuroradiology/canadian-experience-with-the-pipeline-embolization-device-for-repair-Jrfc8K6noM

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
American Journal of Neuroradiology
Copyright
Copyright © 2013 by the American Society of Neuroradiology.
ISSN
0195-6108
eISSN
1936-959X
DOI
10.3174/ajnr.A3224
pmid
22859284
Publisher site
See Article on Publisher Site

Abstract

BACKGROUND AND PURPOSE: Flow-diverting stents, such as the PED, have emerged as a novel means of treating complex intracranial aneurysms. This retrospective analysis of the initial Canadian experience provides insight into technical challenges, clinical and radiographic outcomes, and complication rates after the use of flow-diverting stents for unruptured aneurysms. MATERIALS AND METHODS: Cases were compiled from 7 Canadian centers between July 2008 and December 2010. Each center prospectively tracked their initial experience; these data were retrospectively updated and pooled for analysis. RESULTS: During the defined study period, 97 cases of unruptured aneurysm were treated with the PED, with successful stent deployment in 94 cases. The overall complete or near-complete occlusion rate was 83%, with a median follow-up at 1.25 years (range 0.25–2.5 years). Progressive occlusion was witnessed over time, with complete or near-complete occlusion in 65% of aneurysms followed through 6 months, and 90% of aneurysms followed through 1 year. Multivariate analysis found previous aneurysm treatment and female sex predictive of persistent aneurysm filling. Most patients were stable or improved (88%), with the most favorable outcomes observed in patients with cavernous carotid aneurysms. The overall mortality rate was 6%. Postprocedural aneurysm hemorrhage occurred in 3 patients (3%), while ipsilateral distal territory hemorrhage was observed in 4 patients (3.4%). CONCLUSIONS: Flow-diverting stents represent an important tool in the treatment of complex intracranial aneurysms. The relative efficacy and morbidity of this treatment must be considered in the context of available alternate interventions. ABBREVIATIONS: ICH intracerebral hemorrhage PED Pipeline embolization device

Journal

American Journal of NeuroradiologyAmerican Journal of Neuroradiology

Published: Feb 1, 2013

There are no references for this article.