TY - JOUR AU - Wu,, Ching-Wen AB - Abstract View largeDownload slide View largeDownload slide OBJECTIVES We used a vascular ring connector (Vasoring) and a conventional elephant trunk graft for complete repair in open surgery for type A aortic dissection. This report described the immediate and mid-term results of this new technique. METHODS We used a rigid titanic ring as a stent in the vascular graft for rapid sutureless anastomosis in the reconstruction of type A aortic dissection. RESULTS A total of 65 consecutive patients with Stanford type A aortic dissection underwent open surgery performed by a single surgeon from November 2007 to February 2017. All patients underwent aortic reconstruction with vascular grafts and Vasorings (21 patients in the ascending aorta and 44 patients in the total aortic arch). For total aortic arch replacement, we implanted the conventional vascular graft in the proximal descending thoracic aorta as an elephant trunk graft. Concomitant procedures included the Bentall procedure (9 patients), the David operation (6 patients), coronary artery bypass grafting (9 patients), heart transplantation (1 patient), mitral valve replacement (2 patients) and endovascular aortic repair (1 patient). The mean duration of postoperative endotracheal intubation was 17.0 ± 11.8 h. The average blood loss was 520 ± 743 ml, and 25% of patients required no blood transfusion. The in-hospital mortality rate was 6%. CONCLUSIONS The combined use of the vascular ring connector and the conventional elephant trunk graft may reduce bleeding and pump time, stop the blood flow in the false lumen and allow the 1-stage total arch replacement to be performed safely. The conventional elephant trunk graft is free from stent graft-induced new entry. Aortic dissection, Total arch replacement, Vascular ring connector, Conventional elephant trunk graft, Intraluminal graft, Vasoring INTRODUCTION The surgical repair of Stanford type A aortic dissection is a challenging procedure, considering risks such as bleeding from anastomosis, prolonged cardiopulmonary bypass and organ ischaemia. To reduce bleeding, the intraluminal sutureless ringed vascular graft has been employed for anastomosis [1–4]. The use of commercial products (Meadox Medical Inc., Oakland, NJ, USA) yields satisfactory initial results but has been later considered unsafe due to pseudoaneurysm formation [5, 6]. After further investigation, we determined that the pseudoaneurysms were caused by ring dislodgement [7]. A new metallic ring with fixation furrow (Vasoring®; Sunwei Technology Co., Taipei, Taiwan) was designed to prevent dislodgement. The Vasoring comprises a biocompatible titanium alloy and is available in various sizes. Since 2007, we have been using the Vasoring for both type A and type B aortic dissections, and early and mid-term results have been excellent [7–9]. In this article, we presented our mid-term results for the combined use of the Vasoring and the conventional elephant trunk graft in patients with type A aortic dissection. MATERIALS AND METHODS Following the acquisition of the institutional review board approval from Cheng-Hsin General Hospital and Tung’s Taichung Metro Harbour Hospital, we reviewed the data of 65 consecutive patients with type A aortic dissection [48 men, 17 women; mean age of the patients 56.9 ± 14.1 years (range 22–88 years)] treated with 1-stage open reconstruction from November 2007 to February 2017. The requirement for acquisition of informed consent from patients was waived due to the retrospective nature of this study. The mean follow-up duration was 39 ± 33 months (1–116 months), with a median of 30 months (14–54 months, 25–75%). Twelve patients underwent previous surgery for aortic dissection. Furthermore, 2 patients experienced major strokes, and 1 had severe Fournier gangrene before surgery. Preoperative assessments Multidetector computed tomography (MDCT) of the thoraco-abdominal aorta was performed before surgery. The location of entry tear, blood supply to the visceral organs and the side of the common femoral artery arising from the true lumen were assessed. The anatomy of arch branches including the innominate artery, the right common carotid artery, the left common carotid artery and the left subclavian artery was examined. Cardiac MDCT was routinely performed to rule out coronary artery disease. After intubation, we routinely employed transoesophageal echocardiography to detect the entry tear and blood flow in the false lumen. Total aortic arch replacement surgical techniques Our earlier technique for total aortic arch replacement was described in 2012 [7] (Fig. 1 and Video 1). After July 2014, we have modified the procedure to its current state. Figure 1: View largeDownload slide Total aortic arch replacement with the Vasoring in the middle aortic arch. The numbers in the figure correspond to the sequence of procedures mentioned in the text. CCA: common carotid artery; Lt: left; Rt: right; SCA: subclavian artery. Figure 1: View largeDownload slide Total aortic arch replacement with the Vasoring in the middle aortic arch. The numbers in the figure correspond to the sequence of procedures mentioned in the text. CCA: common carotid artery; Lt: left; Rt: right; SCA: subclavian artery. Video 1: Our techniques for total arch replacement are shown. A 46-year-old man with type A aortic dissection was transferred to our institution for aortic reconstruction from another hospital in which he underwent axillofemoral and femorofemoral bypass for leg ischaemia. Video 1: Our techniques for total arch replacement are shown. A 46-year-old man with type A aortic dissection was transferred to our institution for aortic reconstruction from another hospital in which he underwent axillofemoral and femorofemoral bypass for leg ischaemia. Close The steps of our procedure are as follows: Preparation: prior to induction, pressure cannulae are inserted into both radial arteries. Three 8-mm gel-sealed Dacron grafts are individually anastomosed to the bilateral common carotid arteries and the healthier side of the common femoral artery. To prevent limb ischaemia, we prefer the use of a Dacron graft anastomosed to the femoral artery instead of a cannula directly inserted into the femoral artery for cardiopulmonary bypass. After sternotomy and heparin administration, the right atrium is cannulated, and patients undergo cardiopulmonary bypass using 2 carotid arterial cannulae and 1 venous return cannula in the right atrium. Decision-making: the ascending aorta is incised, and a single shot of histidine–tryptophan–ketoglutarate solution (Custodiol; Essential Pharmaceuticals LLC, Newtown, PA, USA) is delivered to the coronary arteries. If the intimal tear is located at the mid-ascending aorta, only the ascending aorta is replaced [7]. If the tear is very close to the aortic valve, we proceed with the Bentall procedure or the David operation [7]. If the entry tear is located at the aortic arch, total aortic arch replacement is performed. Replacement of the ascending aorta only (without arch replacement): the size of the true lumen is measured, and a Dacron graft of the corresponding size is chosen. The length of the Dacron graft is equal to the length of the ascending aorta. Two Vasorings are placed at either ends of the Dacron graft and fixed with sutures. The ringed Dacron graft is subsequently inserted into the ascending aorta, and the Dacron tapes are used to secure the Vasorings from outside of the aorta. There are 2 furrows on the outer surface of the Vasoring—namely, the smaller furrow, which is used to fix the ring to the graft by sutures, and the larger furrow, which is used for fixation with tapes between the ring and the aorta. The left common carotid artery to the left subclavian artery transposition (Fig. 1, steps 1–3): we extend the upper sternotomy skin incision obliquely by 4 cm to the left lower neck and divide the sternal head of the left sternocleidomastoid muscle to freely expose the left common carotid and left subclavian arteries. The left common carotid artery is divided and anastomosed to the left subclavian artery in an end-to-side or end-to-end fashion. Creation of an elephant trunk graft: the graft is preferably a less stretchable Dacron graft, such as Gelsoft Plus (Vascutek Ltd., Renfrewshire, Scotland). A Vasoring (20–30 mm in diameter depending on the size of the true lumen) is inserted into the centre of the graft and fixed with sutures. The distal arm is used for the elephant trunk graft. The length of the elephant trunk graft is preferably 13–15 cm. Replacement of the proximal portion of the ascending aorta: a Vasoring is inserted into a Dacron graft with a size corresponding to the true lumen of the aortic root and is fixed to 1 end of the graft. The ringed end of the graft is further inserted into the aortic root and fixed to the aorta with several tapes from the outside of the aorta. Insertion of the elephant trunk graft using the guidewire pulling technique (Video 2): a long guidewire (Radifocus; Terumo Corporation, Tokyo, Japan) is inserted into the common femoral artery graft and is forwarded upwards until it comes out from the aortotomy. The aortic lumen is inspected to ensure that the guidewire is in the true lumen. The tip of the elephant trunk graft is attached to the guidewire and is pulled into the descending thoracic aorta by the guidewire. The Vasoring is subsequently fixed to the aorta with tapes at the mid-aortic arch. Aorto-right common carotid artery bypass and aorto-left common carotid artery bypass: the right common carotid artery graft is disconnected from the perfusion system and anastomosed in an end-to-side fashion to the proximal end of the elephant trunk graft (Fig. 1, step 4). Another 8-mm graft is anastomosed to the right common carotid artery graft to form a Y-shaped side arm (Fig. 1, step 5). The proximal end of the elephant trunk graft is anastomosed to the Dacron graft in the aortic root (Fig. 1, step 6). Systemic perfusion is reinstituted by declamping the femoral perfusion cannula. The blood is rewarmed, and the side arm of the right common carotid artery graft is anastomosed to the left common carotid artery graft (Fig. 1, step 7). In heavier patients, as an 8-mm graft is probably insufficient for upper body blood circulation, we suggest the use of a larger bifurcated Y-graft (e.g. 16 mm × 8 mm × 8 mm) or separated anastomotic sites for an aortocarotid bypass. Preventive axillofemoral artery bypass: After the completion of arch replacement and restoration of systemic circulation, blood pressures in the upper and lower extremities are measured. If the pressure gradient is over 30 mmHg, axillofemoral bypass or aortofemoral bypass is immediately performed as a concomitant procedure. Video 2: The guidewire pulling technique for the implantation of the conventional elephant trunk graft in an in vitro 3-dimensional plastic model of a real human aorta is shown. Video 2: The guidewire pulling technique for the implantation of the conventional elephant trunk graft in an in vitro 3-dimensional plastic model of a real human aorta is shown. Close Reoperative surgery for type A aortic dissection In reoperative cases, the pump is instituted prior to the performance of sternotomy. In the event of aortic injury during sternotomy, the femoral bypass is stopped, and the brain perfusion is maintained by the isolated carotid perfusion at a rate of 1000–1500 ml/min. The remaining procedures are the same as above (https://www.youtube.com/watch? v=iaHrincvr60&t=117s). Follow-up All patients except for those who died in the early postoperative period underwent MDCT studies after surgery and were followed up later using MDCT aortography every year. Remodelling of the true and false lumens and recurrence of dissection were observed. Furthermore, patients were followed up for their late complications or death. A representative MDCT image is shown in Fig. 2. Figure 2: View largeDownload slide A 50-year-old man with type A aortic dissection was transferred to our institution for aortic reconstruction from another hospital in which he underwent axillofemoral and femorofemoral bypass for leg ischaemia. (A) A preoperative computed tomography (CT) image. (B) A postoperative CT image. Lt: left; Rt: right. Figure 2: View largeDownload slide A 50-year-old man with type A aortic dissection was transferred to our institution for aortic reconstruction from another hospital in which he underwent axillofemoral and femorofemoral bypass for leg ischaemia. (A) A preoperative computed tomography (CT) image. (B) A postoperative CT image. Lt: left; Rt: right. Statistics Continuous variables are presented as mean ± standard deviation. Postoperative survival analysis was performed with the Kaplan–Meier survival curve using the IBM SPSS Statistics version 24.0 (IBM Corp., Armonk, NY, USA). RESULTS Study population A total of 65 consecutive patients with Stanford type A aortic dissection underwent open repair by the first author from November 2007 to February 2017 (Table 1). All patients received 1-stage repair with the Dacron vascular grafts and the Vasorings (21 in the ascending aorta and 44 in the total aortic arch). Elephant trunk grafts were used in all patients who underwent total aortic arch replacement. Some patients underwent concomitant procedures, including the Bentall procedure for 9 patients, the David operation for 6 patients, coronary artery bypass grafting for 9 patients, heart transplantation for 1 patient [10], mitral valve replacement for 2 patients and thoracic endovascular aortic repair for 1 patient. Four patients required axillofemoral bypass due to a small true lumen. Table 1: Demographics and operative characteristics (N = 65) N (%) Mean ± SD (min–max) Demographics  Age 56.9 ± 14.1 (21–88)  Gender   Male 48 (74)   Female 17 (26)  Dissection type   Acute 44 (68)   Chronic 21 (32)  Redo procedures 12 (19)  Preoperative risk factors   Major stroke 2 (3)   Severe Fournier gangrene 1 (2) Operative characteristics  Segments for reconstruction   The ascending aorta 21 (32)   The total aortic arch 44 (68)  Concomitant procedures   The Bentall procedure 9 (14)   The David operation 6 (9)   Coronary artery bypass grafting 9 (14)   Heart transplantation 1 (2)   Mitral valve replacement 2 (3)   Endovascular aortic repair 1 (2)   Axillofemoral bypass 4 (6)  Cardiopulmonary bypass time (min) 200.2 ± 76.9 (61–559)  Circulatory arrest time for the viscera and lower body (min) 118.0 ± 46.9 (0–267)  Endotracheal intubation time (h) 17.0 ± 11.8 (2–60)  Blood loss amount during procedure (ml) 520.8 ± 743.7 (200–4000)  No blood transfusion during hospitalization 16 (25) N (%) Mean ± SD (min–max) Demographics  Age 56.9 ± 14.1 (21–88)  Gender   Male 48 (74)   Female 17 (26)  Dissection type   Acute 44 (68)   Chronic 21 (32)  Redo procedures 12 (19)  Preoperative risk factors   Major stroke 2 (3)   Severe Fournier gangrene 1 (2) Operative characteristics  Segments for reconstruction   The ascending aorta 21 (32)   The total aortic arch 44 (68)  Concomitant procedures   The Bentall procedure 9 (14)   The David operation 6 (9)   Coronary artery bypass grafting 9 (14)   Heart transplantation 1 (2)   Mitral valve replacement 2 (3)   Endovascular aortic repair 1 (2)   Axillofemoral bypass 4 (6)  Cardiopulmonary bypass time (min) 200.2 ± 76.9 (61–559)  Circulatory arrest time for the viscera and lower body (min) 118.0 ± 46.9 (0–267)  Endotracheal intubation time (h) 17.0 ± 11.8 (2–60)  Blood loss amount during procedure (ml) 520.8 ± 743.7 (200–4000)  No blood transfusion during hospitalization 16 (25) SD: standard deviation. View Large Table 1: Demographics and operative characteristics (N = 65) N (%) Mean ± SD (min–max) Demographics  Age 56.9 ± 14.1 (21–88)  Gender   Male 48 (74)   Female 17 (26)  Dissection type   Acute 44 (68)   Chronic 21 (32)  Redo procedures 12 (19)  Preoperative risk factors   Major stroke 2 (3)   Severe Fournier gangrene 1 (2) Operative characteristics  Segments for reconstruction   The ascending aorta 21 (32)   The total aortic arch 44 (68)  Concomitant procedures   The Bentall procedure 9 (14)   The David operation 6 (9)   Coronary artery bypass grafting 9 (14)   Heart transplantation 1 (2)   Mitral valve replacement 2 (3)   Endovascular aortic repair 1 (2)   Axillofemoral bypass 4 (6)  Cardiopulmonary bypass time (min) 200.2 ± 76.9 (61–559)  Circulatory arrest time for the viscera and lower body (min) 118.0 ± 46.9 (0–267)  Endotracheal intubation time (h) 17.0 ± 11.8 (2–60)  Blood loss amount during procedure (ml) 520.8 ± 743.7 (200–4000)  No blood transfusion during hospitalization 16 (25) N (%) Mean ± SD (min–max) Demographics  Age 56.9 ± 14.1 (21–88)  Gender   Male 48 (74)   Female 17 (26)  Dissection type   Acute 44 (68)   Chronic 21 (32)  Redo procedures 12 (19)  Preoperative risk factors   Major stroke 2 (3)   Severe Fournier gangrene 1 (2) Operative characteristics  Segments for reconstruction   The ascending aorta 21 (32)   The total aortic arch 44 (68)  Concomitant procedures   The Bentall procedure 9 (14)   The David operation 6 (9)   Coronary artery bypass grafting 9 (14)   Heart transplantation 1 (2)   Mitral valve replacement 2 (3)   Endovascular aortic repair 1 (2)   Axillofemoral bypass 4 (6)  Cardiopulmonary bypass time (min) 200.2 ± 76.9 (61–559)  Circulatory arrest time for the viscera and lower body (min) 118.0 ± 46.9 (0–267)  Endotracheal intubation time (h) 17.0 ± 11.8 (2–60)  Blood loss amount during procedure (ml) 520.8 ± 743.7 (200–4000)  No blood transfusion during hospitalization 16 (25) SD: standard deviation. View Large Immediate results Excluding 4 cases of mortality, the duration of endotracheal intubation after surgery was 17.0 ± 11.8 h (Table 1). The average blood loss was 520.8 ± 743.7 ml, and 25% of patients did not require blood transfusion during and after surgery. Flow in the false lumen on transoesophageal echocardiography In all cases, transoesophageal echocardiography revealed immediate cessation of blood flow in the false lumen prior to sternal closure. Complications and hospital mortality Four hospital deaths occurred (Table 2). Two patients died of sepsis related to poor preoperative conditions: 1 had a major stroke and the other, Fournier gangrene. One patient died of deep sternal wound infection. Two patients had paraplegia, of whom one recovered and the other died. Two patients experienced a late-onset minor stroke during hospitalization. No bleeding complication related to anastomosis was observed. The in-hospital mortality rate was 6% (4/65). Table 2: Outcomes N (%) Mean ± SD (min–max) Follow-up duration (months) 39 ± 33 (1–116) In-hospital mortality  Sepsis from deep sternal wound infection 1 (2)  Paraplegia 1 (2) In-hospital mortality related to preoperative critical condition 2 (3) Early complications  Paraplegia 2 (3)  Late-onset minor stroke 2 (3) Late mortality  Brain infarct 2 (3)  Intracranial haemorrhage 1 (2)  Sepsis 1 (2)  Prostate cancer 1 (2) Late minor complications 5 (8)  Minor stroke 3 (5)  Peripheral thromboembolism 2 (3)  Pseudoaneurysm 0 Readmission for axillofemoral bypass 3 (5) N (%) Mean ± SD (min–max) Follow-up duration (months) 39 ± 33 (1–116) In-hospital mortality  Sepsis from deep sternal wound infection 1 (2)  Paraplegia 1 (2) In-hospital mortality related to preoperative critical condition 2 (3) Early complications  Paraplegia 2 (3)  Late-onset minor stroke 2 (3) Late mortality  Brain infarct 2 (3)  Intracranial haemorrhage 1 (2)  Sepsis 1 (2)  Prostate cancer 1 (2) Late minor complications 5 (8)  Minor stroke 3 (5)  Peripheral thromboembolism 2 (3)  Pseudoaneurysm 0 Readmission for axillofemoral bypass 3 (5) SD: standard deviation. View Large Table 2: Outcomes N (%) Mean ± SD (min–max) Follow-up duration (months) 39 ± 33 (1–116) In-hospital mortality  Sepsis from deep sternal wound infection 1 (2)  Paraplegia 1 (2) In-hospital mortality related to preoperative critical condition 2 (3) Early complications  Paraplegia 2 (3)  Late-onset minor stroke 2 (3) Late mortality  Brain infarct 2 (3)  Intracranial haemorrhage 1 (2)  Sepsis 1 (2)  Prostate cancer 1 (2) Late minor complications 5 (8)  Minor stroke 3 (5)  Peripheral thromboembolism 2 (3)  Pseudoaneurysm 0 Readmission for axillofemoral bypass 3 (5) N (%) Mean ± SD (min–max) Follow-up duration (months) 39 ± 33 (1–116) In-hospital mortality  Sepsis from deep sternal wound infection 1 (2)  Paraplegia 1 (2) In-hospital mortality related to preoperative critical condition 2 (3) Early complications  Paraplegia 2 (3)  Late-onset minor stroke 2 (3) Late mortality  Brain infarct 2 (3)  Intracranial haemorrhage 1 (2)  Sepsis 1 (2)  Prostate cancer 1 (2) Late minor complications 5 (8)  Minor stroke 3 (5)  Peripheral thromboembolism 2 (3)  Pseudoaneurysm 0 Readmission for axillofemoral bypass 3 (5) SD: standard deviation. View Large Late outcomes and long-term survival Five late mortalities (8%) occurred due to the following reasons: brain infarct in 2 patients, intracranial haemorrhage in 1 patient, sepsis in 1 patient and prostate cancer in 1 patient (Table 2 and Fig. 3). Three and 2 patients had a minor stroke and peripheral thromboembolism, respectively. None had pseudoaneurysm formation at the anastomotic site of the Vasoring. There was no extension of the elephant trunk graft in patients followed up using MDCT. Three needed readmission for axillofemoral bypass due to intermittent claudication. None of the late mortalities were related to aortic dissection. Figure 3: View largeDownload slide The Kaplan–Meier survival curve for patients with postoperative type A aortic dissection. Figure 3: View largeDownload slide The Kaplan–Meier survival curve for patients with postoperative type A aortic dissection. DISCUSSION Total aortic arch replacement in 1 stage Replacing the ascending aorta, the aortic arch and the proximal portion of the descending thoracic aorta in 1 stage was previously considered difficult due to the anterior location and posterior location of the ascending aorta and the descending thoracic aorta, respectively. The exposure of the distal arch and the frailty of the aortic wall are the critical issues of this type of surgery. The combined use of the Vasoring and the conventional elephant trunk graft may simplify the total arch replacement procedure and feasibly enable its completion in 1 stage. To date, almost all the surgeons in our hospital have successfully performed it independently. Conventional elephant trunk graft or stent graft? The elephant trunk graft proposed by Borst et al. [11, 12] is an ingenious idea. During their era, a conventional Dacron graft was used as the elephant trunk graft. The use of the conventional elephant trunk graft can help achieve haemostasis without exploring the distal portion of the aorta in surgeries for aortic aneurysm. This is even more important in surgeries for aortic dissection. The implantation of a conventional ‘soft’ elephant trunk graft in the aorta may not only prevent the backflow of blood but also protect the fragile intima from further damage. However, the suitable method for soft graft implantation in the fragile aorta remains a technical problem. Because of the high risks of conventional open surgery, the stent graft (the frozen elephant trunk graft) has been used to treat aortic dissection since 1999 [13–15]. However, some limitations and complications still exist, such as the lack of a healthy landing zone and the risk of stent graft-induced new entry (SINE) [16]. In this study, we listed the advantages and disadvantages of ‘conventional’ and ‘frozen’ elephant trunk grafts: Implantation technique: the frozen elephant trunk graft can be easily introduced into the true lumen in both antegrade and retrograde directions. The conventional elephant trunk graft can only be implanted into the aorta through the aortotomy (i.e. in an antegrade manner). However, pushing a long soft Dacron graft into the aorta without kinking is not only difficult but also risky. We currently propose a simple way to achieve this goal: the guidewire pulling technique (Video 2). Fixation of the elephant trunk graft: the stent graft can be fixed in the lumen if there is adequate landing zone or if the intimal tissue is sufficiently strong to hold the graft, which is usually impossible in type A aortic dissection. However, there are also difficulties in fixing the proximal end of the conventional elephant trunk graft to the aorta. The conventional strategy is the use of stitches to sew the Dacron graft to the aortic wall. Nonetheless, the ascending aorta and the aortic arch in type A aortic dissection are involved by the dissection flap, making the sewing technique very difficult and time-consuming. Moreover, bleeding from sewing holes may increase the mortality rate. Our technique of using the Vasoring for the proximal anastomosis remarkably reduces the technical difficulties, with an average pump time of 200 min, a circulatory arrest time of 118 min for the viscera and lower body and an acceptable blood loss of only 521 ml. Cost: to use the conventional elephant trunk graft, we need no cost for the delivery system and the expensive stent graft. What are only required are a guidewire and a conventional Dacron graft. The Vasoring is much cheaper than the stent graft. Efficiency in stopping the backflow from the true lumen to the false lumen: in an animal model, we inserted a soft Dacron graft into the porcine aorta that consisted of holes at various distances, similar to the condition of the conventional elephant trunk graft placed in the dissected aorta with the entry tear. When the aorta was placed on circulation in a close circuit with normal blood pressure, there was no backflow to the hole if it was >3 cm away from the tip of the vascular graft. This indicates that the distal end of a soft Dacron graft 3 cm away from the intimal tear may stop the backflow from the true lumen to the false lumen. Our conventional elephant trunk graft is 12–15 cm in length (measured from the mid-aortic arch), with a tip that is usually 3 cm distal to the intimal tear (even if it is located at the distal arch). This could explain our observation on transoesophageal echocardiography that the backflow to the false lumen in almost all patients could be stopped prior to sternotomy closure. This in vitro study will be submitted for publication in the near future. SINE: our clinical results confirmed that we do not need to be concerned about SINE when using the conventional elephant trunk graft. Left common carotid artery to left subclavian artery transposition Interposition of the vascular prosthesis is commonly employed to establish a left common carotid artery to the left subclavian artery bypass in thoracic endovascular aortic repair [17]. Another approach is the direct left common carotid artery to left subclavian artery transposition, which is carried out by transecting the left subclavian artery and anastomosing it to the left common carotid artery in an end-to-side fashion [18]. Our unique technique was to perform the left common carotid artery to left subclavian artery transposition during dissection surgery. The left common carotid and left subclavian arteries are very close and located just beneath the sternocleidomastoid muscle. After dividing the sternal head of the sternocleidomastoid muscle, a direct end-to-side anastomosis or an end-to-end anastomosis of the 2 vessels is easy to perform. On the basis of our follow-up observations, repairing this muscle is unnecessary. Bleeding Tape fixation for the Vasoring provides a much larger contact surface area at the anastomotic site than the suture technique, thus reducing the risk of bleeding. Moreover, rapid anastomosis may shorten the extracorporeal circulation time, potentially reducing coagulopathy and blood loss. In our series, the average amount of blood transfusion during and after surgery was only 1 unit. Brain ischaemia The brain was continuously perfused with blood throughout the entire procedure; thus, none of our patients developed brain ischaemia during and after surgery. Spinal cord and abdominal visceral organ ischaemia Because of the short ischaemic time, none of our patients developed abdominal visceral organ ischaemia. The paraplegia in 2 patients might have been due to the compromised spinal cord arteries that were previously supplied by the upper descending thoracic artery or false lumen. True lumen remodelling and axillofemoral bypass One of our unpublished studies (will be submitted for publication in the near future) showed that remodelling of the true lumen after using the conventional elephant trunk graft was similar to the use of the stent graft. In acute dissection, most true lumen sizes returned to normal or near normal. In chronic dissection, most true lumens were also enlarged but to a lesser extent. Only few still had very small true lumen after surgery. As we had more patients referred from other hospitals for surgery, we had more chronic dissection patients (32%). Therefore, the incidence of axillofemoral bypass was higher (4 preventive during the first surgery and 3 after discharge). Prior to surgical wound closure, we measured the blood pressures in the upper and lower extremities. In the event of a high-pressure gradient across the upper and lower bodies, we performed preventive axillofemoral or aortofemoral bypass. Interestingly, we did not observe visceral ischaemia related to a small true lumen, which might have been due to the preventive axillofemoral bypass that provided retrograde blood perfusion to the visceral organs. Reoperation for type A aortic dissection Twelve patients (19%) were referred for reoperation from other hospitals in which only the ascending aorta was replaced. All had residual entry tears at the aortic arch. Reoperation was indicated because of the progressive dilatation of the false lumen, leading to compression syndrome. As the aorta may tightly adhere to the sternum, resternotomy is very risky. We will initially anastomose Dacron grafts to the bilateral carotid arteries and femoral artery, insert a venous return cannula into the right atrium via the femoral vein and subsequently place patients on cardiopulmonary bypass prior to the performance of resternotomy. If aortic injury occurs upon opening the sternum, femoral perfusion is stopped to prevent exsanguination. Moreover, the brain is protected by continuous perfusion through the carotid arteries. We prefer to use a regular sternal saw rather than a sagittal saw, which can still injure the aorta in the presence of severe adhesion. We believe that the use of a sagittal saw will delay the opening time and may result in more blood loss. With this technique, some of our reoperative patients did not even required a blood transfusion (https://www.youtube.com/watch? v=S60OnQn-fgo&t=8s). Pseudoaneurysm formation An intraluminal sutureless graft was used for aortic dissection in early years [1–4]. However, its use was discontinued due to pseudoaneurysm formation [5, 6]. Out of curiosity, we removed the Teflon cloth of the ring and observed that it was a plastic ring with a smooth surface. This might be the reason for the dislodgement from the fixation tapes and subsequent pseudoaneurysm formation. In our chronic animal experiments, in accordance with the Food and Drug Administration’s requirements, we implanted the Vasorings in the adult porcine abdominal aorta and explanted them 6 months later. We found that the Vasorings were tightly covered by dense fibrotic tissue, without dislodgement or aortic wall necrosis. The mid-term follow-up of our patients also indicated the absence of pseudoaneurysm formation. Vasoring design The Vasoring is made of a biocompatible titanium alloy. The depth of the furrow used to fix the ring to the aortic wall varies with the ring diameter and is related to the security of the tape fixation. The deeper the furrow is, the safer the fixation. We had increased the depth of the furrow in the new-generation Vasoring to make it safer in fixation. To decrease the probability of thromboembolism, we may have to replace the smooth surface of the Vasoring with sintered titanium alloy. Limitations This study has some limitations. First, the follow-up duration was not sufficiently long. Second, there exists a concern about thromboembolism due to the use of the Vasoring. Third, the total arch replacement technique is complicated, and a learning curve is required to achieve a high successful rate. CONCLUSIONS Based on the obtained results, the following conclusions can be drawn. First, the use of the Vasoring is not only simple but it may also reduce surgical risks, including bleeding and organ ischaemia. Second, the conventional elephant trunk graft can effectively stop the flow to the false lumen, allow remodelling of the true lumen and is free from SINE. Third, with the use of the Vasoring and conventional elephant trunk graft, 1-stage total aortic arch replacement for type A aortic dissection can be safely performed. Finally, we suggest that the total aortic arch be repaired in 1 stage and that the residual intimal tear not be left for the second surgery. Long-term follow-up is required before a definite conclusion can be drawn. ACKNOWLEDGEMENTS The authors thank Joseph J. Chang for his continued support in the form of technical advice and experimental design of the Vasoring. Conflict of interest: Jeng Wei is the consultant of Sunwei Technology Co. Yung-Tsai Lee and Ching-Wen Wu have no conflicts of interest to report. REFERENCES 1 Dureau G , Villard J , George M , Deliry P , Froment JC , Clermont A. New surgical technique for the operative management of acute dissections of the ascending aorta. Report of two cases . J Thorac Cardiovasc Surg 1978 ; 76 : 385 – 9 . Google Scholar PubMed 2 Ablaza SG , Ghosh SC , Grana VP. Use of a ringed intraluminal graft in the surgical treatment of dissecting aneurysms of the aorta. A new technique . J Thorac Cardiovasc Surg 1978 ; 76 : 390 – 6 . Google Scholar PubMed 3 Oz MC , Ashton RC Jr , Singh MK , Serra JS , Lemole GM. Twelve-year experience with intraluminal sutureless ringed graft replacement of the descending thoracic and thoracoabdominal aorta . J Vasc Surg 1990 ; 11 : 331 – 8 . Google Scholar Crossref Search ADS PubMed 4 Liu DW , Lin PJ , Chang CH. Treatment of acute type A aortic dissection with intraluminal sutureless prosthesis . Ann Thorac Surg 1994 ; 57 : 987 – 91 . Google Scholar Crossref Search ADS PubMed 5 Chang JP , Lu HI , Hsieh MJ , Kao CL , Wu CJ. Pseudo-aneurysm formation 12 years after ringed intraluminal graft replacement for type B aortic dissection . Chang Gung Med J 2004 ; 27 : 614 – 17 . Google Scholar PubMed 6 West D , Scott DH , Walker WS. Complete aortic dehiscence as a late complication of an aortic sutureless graft . Eur J Cardiothorac Surg 2008 ; 34 : 451. Google Scholar Crossref Search ADS PubMed 7 Wei J , Chang CY , Chuang YC , Sue SH , Lee KC , Wu CW et al. Midterm results of vascular ring connector in open surgery for aortic dissection . J Thorac Cardiovasc Surg 2012 ; 143 : 72. Google Scholar Crossref Search ADS PubMed 8 Wei J , Chang CY , Chuang YC , Sue SH , Lee KC , Tung D. A new vascular ring connector in surgery for aortic dissection . J Thorac Cardiovasc Surg 2009 ; 138 : 674 – 7 . Google Scholar Crossref Search ADS PubMed 9 Chen IM , Chen PL , Weng SH , Hsu CP , Shih CC , Chang HH et al. Clinical outcomes of Vasoring connector in patients with acute type A aortic dissection . Ann Thorac Surg 2018 ; 106 : 764 – 70 . Google Scholar Crossref Search ADS PubMed 10 Wei J , Sue SH , Lee YT , Chang CY. Combined heart transplantation and total replacement of thoracic aorta in Marfan’s syndrome with recurrent aortic dissection: a case report . Transplant Proc 2012 ; 44 : 1174 – 5 . Google Scholar Crossref Search ADS PubMed 11 Borst HG , Walterbusch G , Schaps D. Extensive aortic replacement using “elephant trunk” prosthesis . Thorac Cardiovasc Surg 1983 ; 31 : 37 – 40 . Google Scholar Crossref Search ADS PubMed 12 Svensson LG , Kim KH , Blackstone EH , Alster JM , McCarthy PM , Greenberg RK et al. Elephant trunk procedure: newer indications and uses . Ann Thorac Surg 2004 ; 78 : 109 – 16 . Google Scholar Crossref Search ADS PubMed 13 Nienaber CA , Fattori R , Lund G , Dieckmann C , Wolf W , von Kodolitsch Y et al. Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement . N Engl J Med 1999 ; 340 : 1539 – 45 . Google Scholar Crossref Search ADS PubMed 14 Dake MD , Kato N , Mitchell RS , Semba CP , Razavi MK , Shimono T et al. Endovascular stent-graft placement for the treatment of acute aortic dissection . N Engl J Med 1999 ; 340 : 1546 – 52 . Google Scholar Crossref Search ADS PubMed 15 Parsa CJ , Williams JB , Bhattacharya SD , Wolfe WG , Daneshmand MA , McCann RL et al. Midterm results with thoracic endovascular aortic repair for chronic type B aortic dissection with associated aneurysm . J Thorac Cardiovasc Surg 2011 ; 141 : 322 – 7 . Google Scholar Crossref Search ADS PubMed 16 Dong Z , Fu WG , Wang Y , Wang C , Yan Z , Guo D et al. Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection . J Vasc Surg 2010 ; 52 : 1450 – 7 . Google Scholar Crossref Search ADS PubMed 17 Xydas S , Wei B , Takayama H , Russo M , Bacchetta M , Smith CR et al. Use of carotid-subclavian arterial bypass and thoracic endovascular aortic repair to minimize cerebral ischemia in total aortic arch reconstruction . J Thorac Cardiovasc Surg 2010 ; 139 : 717 – 22 . Google Scholar Crossref Search ADS PubMed 18 Morasch MD. Technique for subclavian to carotid transposition, tips, and tricks . J Vasc Surg 2009 ; 49 : 251 – 4 . Google Scholar Crossref Search ADS PubMed © The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved. This article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model) TI - One-stage aortic replacement for type A aortic dissection: using a Vasoring and a conventional elephant trunk graft JF - European Journal of Cardio-Thoracic Surgery DO - 10.1093/ejcts/ezy455 DA - 2019-07-01 UR - https://www.deepdyve.com/lp/oxford-university-press/one-stage-aortic-replacement-for-type-a-aortic-dissection-using-a-xn5lbMi0ts SP - 189 VL - 56 IS - 1 DP - DeepDyve ER -