TY - JOUR AU - Saigusa, Shin AB - Abstract In order to reconstruct organ-absorbed dose from recorded dose for risk estimation in nuclear worker cohort, the preceding study of the International Agency for Research on Cancer (IARC) 15-Country Collaborative Study estimated the organ dose conversion factor from the recorded dose of Hp(10) under the assumption that on average, in the nuclear power plants (NPPs), 10% of the dose received by workers was due to photon energies ranging from 100 to 300 keV and 90% from photon energies ranging from 300 to 3000 keV, with the average geometry being 50% in the antero-posterior geometry and 50% in the isotropic geometry. Similar examination was conducted at the Japanese Epidemiological Study on Low-Dose Radiation Effects (J-EPISODE). Literature survey disclosed that Japanese electric power companies had jointly conducted the research on energy distribution and incidence direction distribution of gamma rays in working environments during periodical inspection and maintenance as well as during operation in the 1980s. The analysis of the survey results on photon energy and geometry distribution of Japanese NPPs demonstrated appropriateness in applying the IARC study assumption for nuclear workers in Japan and reconstructing organ-absorbed dose in the J-EPISODE. These results in Japan also provide strong evidence to support the robustness and generality of the IARC study assumption, which was estimated based on the judgment of experts at nuclear facilities around the world. INTRODUCTION Although the concept of effective dose E and its operational definition of personal equivalent dose Hp(10) are nowadays widely used for radiological protection purpose, the International Commission on Radiological Protection (ICRP) has recommended that effective dose should not be used for epidemiological studies(1). It is desirable to use organ-absorbed dose for the evaluation of cancer morbidity and mortality in epidemiological cohort studies. Organ-absorbed dose was adopted for the International Agency for Research on Cancer (IARC) 15-Country Collaborative Study(2–4), the International Nuclear Workers Study (INWORKS)(5–8), Mayak study(9) and the Life Span Study (LSS) of atomic bomb survivors(10–12). The IARC study assumption was that on average, in the nuclear power plants (NPPs), 10% of the dose received by nuclear workers was due to photon energies ranging from 100 to 300 keV and 90% from photon energies ranging from 300 to 3000 keV, and in the mixed activities (MA) facilities such as research and development organizations and fuel processing factories, 20% from photon energies ranging from 100 to 300 keV and 80% from photon energies ranging from 300 to 3000 keV, with the average geometry being 50% in the antero-posterior (AP) geometry and 50% in the isotropic (ISO) geometry for NPPs and MA facilities(2), as shown in Table 1. Here, the exposure by nuclear workers was regarded to be derived from photon at energy level of 0.1–3 MeV and in AP geometry and ISO geometry, meaning that photon with energy over 3 MeV, exposure in rotational (ROT) geometry, neutron exposure and intakes of nuclides were thought to be negligible in the estimation of organ-absorbed dose. The IARC study determined the above-mentioned exposure condition basically based on the judgment of experts at nuclear facilities around the world, taking into consideration some prior experimental studies(2). Table 1 The assumption of the IARC study; estimated percentage of average doses in nuclear power plants and ‘MA’ facilities from different photon energies and different geometries of exposure. Items . Percentage of dose received from different energy photons (keV) . Percentage of dose received in different geometries . 0–100 . 100–300 . 300–3000 . AP . Isotropic . Rotational . Nuclear power plants  Average dose (%) 0 10 90 50 50 0  Range of dose (minimum–maximum) (%) 0–1 5–20 80–100 10–80 20–90 0  Uncertainty on average and ranges (%) ±5 (2 SD) ±10 (2 SD) ‘MA’ facilities  Average dose (%) 0 20 80 50 50 0 Items . Percentage of dose received from different energy photons (keV) . Percentage of dose received in different geometries . 0–100 . 100–300 . 300–3000 . AP . Isotropic . Rotational . Nuclear power plants  Average dose (%) 0 10 90 50 50 0  Range of dose (minimum–maximum) (%) 0–1 5–20 80–100 10–80 20–90 0  Uncertainty on average and ranges (%) ±5 (2 SD) ±10 (2 SD) ‘MA’ facilities  Average dose (%) 0 20 80 50 50 0 SD, standard deviation. Note: Cited Table 4 in Thierry-Chef (2007)(2) and reproduced by the author. Open in new tab Table 1 The assumption of the IARC study; estimated percentage of average doses in nuclear power plants and ‘MA’ facilities from different photon energies and different geometries of exposure. Items . Percentage of dose received from different energy photons (keV) . Percentage of dose received in different geometries . 0–100 . 100–300 . 300–3000 . AP . Isotropic . Rotational . Nuclear power plants  Average dose (%) 0 10 90 50 50 0  Range of dose (minimum–maximum) (%) 0–1 5–20 80–100 10–80 20–90 0  Uncertainty on average and ranges (%) ±5 (2 SD) ±10 (2 SD) ‘MA’ facilities  Average dose (%) 0 20 80 50 50 0 Items . Percentage of dose received from different energy photons (keV) . Percentage of dose received in different geometries . 0–100 . 100–300 . 300–3000 . AP . Isotropic . Rotational . Nuclear power plants  Average dose (%) 0 10 90 50 50 0  Range of dose (minimum–maximum) (%) 0–1 5–20 80–100 10–80 20–90 0  Uncertainty on average and ranges (%) ±5 (2 SD) ±10 (2 SD) ‘MA’ facilities  Average dose (%) 0 20 80 50 50 0 SD, standard deviation. Note: Cited Table 4 in Thierry-Chef (2007)(2) and reproduced by the author. Open in new tab Table 2 Gamma-ray air dose rate and mean energy during PIM. (1) PWR . Survey spot Location Exposure rate (mR/H) Mean gamma-ray energy (keV) Ionization chamber NaIa Spent fuel pit A/B-5FL 2.4 A 1.6 653 Waste liquid evaporator room A/B-3FL 14 A 17.4 1225 CVCS non-regeneration cooler room A/B-3FL 14 A 8.6 851 RHR cooler room A/B-2FL 8 A 2.5 836 RHR piping area A A/B-1FL 26 A 5.2 920 RHR piping area B A/B-1FL 14 A 3.2 845 RHR pump room A/B-BFL 22 A 19.0 1113 5FL inside C/V C/V-5FL 3.2 A 2.2 793 Loop room entrance C/V-2FL 2.4 A 2.5 661 Beside the SG handhole Loop room 80 D 32.7 685 Below the SG manhole Loop room 36 B 28.7 877 Beside the SG barrier Loop room 30 B 22.1 827 Pressurizer Loop room 18 D 12.7 780 Reactor cooler pump Loop room 30 D 4.0 767 (2) BWR Survey spot Location Exposure rate (mR/H) Mean gamma-ray energy (keV) Ionization chamber NaIa Condensate water filter room T/B-1FL 0.0 C 0.05 859 Condensate demineralizer room T/B-1FL 1.5 C 1.6 771 Radioactive waste disposal pump room RW/B-1FL 2.5 A 4.3 992 Radioactive waste disposal tank room RW/B-1FL 8.0 A 9.7 1097 Fuel inspection area R/B-5FL 1.0 A 1.0 921 5FL inside R/B R/B-5FL 4.0 A 2.6 382 Reactor well inside R/B-5FL 9.0 A 8.3 1017 CRD repair room B R/B-4FL 3.6 C 3.6 866 FPC heat exchanger room R/B-3FL 4.8 A 5.4 807 CUW heat exchanger room R/B-2FL 4.0 A 0.9 633 CUW auxiliary pump room R/B-2FL 3.5 A 2.6 875 Around RHR pump R/B-BFL 6.0 A 1.7 902 Equipment drain sump pump R/B-BFL 3.5 A 4.4 989 Around feed-water nozzle PCV-3FL 3.0 A 2.3 734 Around SRV A PCV-2FL 18.0 A 15.9 1008 Around RHR/CUW piping PCV-2FL 90.0 C 83.4 860 Around PLR ring header PCV-2FL 25.0 C 11.5 736 Around PLR moter PCV-1FL 9.0 A 6.9 1032 Around MSIV PCV-1FL 6.0 A 4.7 879 Machine loading hatch front PCV-1FL 11.0 A 7.3 1053 Pedestal inside PCV-BFL 20.0 A 16.2 1312 Around floor drain sump pump PCV-BFL 8.0 A 4.2 950 (1) PWR . Survey spot Location Exposure rate (mR/H) Mean gamma-ray energy (keV) Ionization chamber NaIa Spent fuel pit A/B-5FL 2.4 A 1.6 653 Waste liquid evaporator room A/B-3FL 14 A 17.4 1225 CVCS non-regeneration cooler room A/B-3FL 14 A 8.6 851 RHR cooler room A/B-2FL 8 A 2.5 836 RHR piping area A A/B-1FL 26 A 5.2 920 RHR piping area B A/B-1FL 14 A 3.2 845 RHR pump room A/B-BFL 22 A 19.0 1113 5FL inside C/V C/V-5FL 3.2 A 2.2 793 Loop room entrance C/V-2FL 2.4 A 2.5 661 Beside the SG handhole Loop room 80 D 32.7 685 Below the SG manhole Loop room 36 B 28.7 877 Beside the SG barrier Loop room 30 B 22.1 827 Pressurizer Loop room 18 D 12.7 780 Reactor cooler pump Loop room 30 D 4.0 767 (2) BWR Survey spot Location Exposure rate (mR/H) Mean gamma-ray energy (keV) Ionization chamber NaIa Condensate water filter room T/B-1FL 0.0 C 0.05 859 Condensate demineralizer room T/B-1FL 1.5 C 1.6 771 Radioactive waste disposal pump room RW/B-1FL 2.5 A 4.3 992 Radioactive waste disposal tank room RW/B-1FL 8.0 A 9.7 1097 Fuel inspection area R/B-5FL 1.0 A 1.0 921 5FL inside R/B R/B-5FL 4.0 A 2.6 382 Reactor well inside R/B-5FL 9.0 A 8.3 1017 CRD repair room B R/B-4FL 3.6 C 3.6 866 FPC heat exchanger room R/B-3FL 4.8 A 5.4 807 CUW heat exchanger room R/B-2FL 4.0 A 0.9 633 CUW auxiliary pump room R/B-2FL 3.5 A 2.6 875 Around RHR pump R/B-BFL 6.0 A 1.7 902 Equipment drain sump pump R/B-BFL 3.5 A 4.4 989 Around feed-water nozzle PCV-3FL 3.0 A 2.3 734 Around SRV A PCV-2FL 18.0 A 15.9 1008 Around RHR/CUW piping PCV-2FL 90.0 C 83.4 860 Around PLR ring header PCV-2FL 25.0 C 11.5 736 Around PLR moter PCV-1FL 9.0 A 6.9 1032 Around MSIV PCV-1FL 6.0 A 4.7 879 Machine loading hatch front PCV-1FL 11.0 A 7.3 1053 Pedestal inside PCV-BFL 20.0 A 16.2 1312 Around floor drain sump pump PCV-BFL 8.0 A 4.2 950 CVCS, chemical and volume control system; RHR, residual heat removal system; SG, steam generator; CRD, control rod drive; FPC, fuel pool cooling and cleanup system; CUW, reactor water cleanup system; SRV, safety relief valve; PLR, primary loop recirculation system; MSIV, main steam isolation valve. aA: 3-inch spherical NaI, B: 2-inch spherical NaI, C: 1-inch spherical NaI, D: 1-inch diameter cylindrical NaI. Note: Reproduced and translated by the author based on Figure 3.4.1 and Table 3.4.3 in REA (2019)(21). The original was Figure A and Table 1 in EPCJCR (1983).(19) Open in new tab Table 2 Gamma-ray air dose rate and mean energy during PIM. (1) PWR . Survey spot Location Exposure rate (mR/H) Mean gamma-ray energy (keV) Ionization chamber NaIa Spent fuel pit A/B-5FL 2.4 A 1.6 653 Waste liquid evaporator room A/B-3FL 14 A 17.4 1225 CVCS non-regeneration cooler room A/B-3FL 14 A 8.6 851 RHR cooler room A/B-2FL 8 A 2.5 836 RHR piping area A A/B-1FL 26 A 5.2 920 RHR piping area B A/B-1FL 14 A 3.2 845 RHR pump room A/B-BFL 22 A 19.0 1113 5FL inside C/V C/V-5FL 3.2 A 2.2 793 Loop room entrance C/V-2FL 2.4 A 2.5 661 Beside the SG handhole Loop room 80 D 32.7 685 Below the SG manhole Loop room 36 B 28.7 877 Beside the SG barrier Loop room 30 B 22.1 827 Pressurizer Loop room 18 D 12.7 780 Reactor cooler pump Loop room 30 D 4.0 767 (2) BWR Survey spot Location Exposure rate (mR/H) Mean gamma-ray energy (keV) Ionization chamber NaIa Condensate water filter room T/B-1FL 0.0 C 0.05 859 Condensate demineralizer room T/B-1FL 1.5 C 1.6 771 Radioactive waste disposal pump room RW/B-1FL 2.5 A 4.3 992 Radioactive waste disposal tank room RW/B-1FL 8.0 A 9.7 1097 Fuel inspection area R/B-5FL 1.0 A 1.0 921 5FL inside R/B R/B-5FL 4.0 A 2.6 382 Reactor well inside R/B-5FL 9.0 A 8.3 1017 CRD repair room B R/B-4FL 3.6 C 3.6 866 FPC heat exchanger room R/B-3FL 4.8 A 5.4 807 CUW heat exchanger room R/B-2FL 4.0 A 0.9 633 CUW auxiliary pump room R/B-2FL 3.5 A 2.6 875 Around RHR pump R/B-BFL 6.0 A 1.7 902 Equipment drain sump pump R/B-BFL 3.5 A 4.4 989 Around feed-water nozzle PCV-3FL 3.0 A 2.3 734 Around SRV A PCV-2FL 18.0 A 15.9 1008 Around RHR/CUW piping PCV-2FL 90.0 C 83.4 860 Around PLR ring header PCV-2FL 25.0 C 11.5 736 Around PLR moter PCV-1FL 9.0 A 6.9 1032 Around MSIV PCV-1FL 6.0 A 4.7 879 Machine loading hatch front PCV-1FL 11.0 A 7.3 1053 Pedestal inside PCV-BFL 20.0 A 16.2 1312 Around floor drain sump pump PCV-BFL 8.0 A 4.2 950 (1) PWR . Survey spot Location Exposure rate (mR/H) Mean gamma-ray energy (keV) Ionization chamber NaIa Spent fuel pit A/B-5FL 2.4 A 1.6 653 Waste liquid evaporator room A/B-3FL 14 A 17.4 1225 CVCS non-regeneration cooler room A/B-3FL 14 A 8.6 851 RHR cooler room A/B-2FL 8 A 2.5 836 RHR piping area A A/B-1FL 26 A 5.2 920 RHR piping area B A/B-1FL 14 A 3.2 845 RHR pump room A/B-BFL 22 A 19.0 1113 5FL inside C/V C/V-5FL 3.2 A 2.2 793 Loop room entrance C/V-2FL 2.4 A 2.5 661 Beside the SG handhole Loop room 80 D 32.7 685 Below the SG manhole Loop room 36 B 28.7 877 Beside the SG barrier Loop room 30 B 22.1 827 Pressurizer Loop room 18 D 12.7 780 Reactor cooler pump Loop room 30 D 4.0 767 (2) BWR Survey spot Location Exposure rate (mR/H) Mean gamma-ray energy (keV) Ionization chamber NaIa Condensate water filter room T/B-1FL 0.0 C 0.05 859 Condensate demineralizer room T/B-1FL 1.5 C 1.6 771 Radioactive waste disposal pump room RW/B-1FL 2.5 A 4.3 992 Radioactive waste disposal tank room RW/B-1FL 8.0 A 9.7 1097 Fuel inspection area R/B-5FL 1.0 A 1.0 921 5FL inside R/B R/B-5FL 4.0 A 2.6 382 Reactor well inside R/B-5FL 9.0 A 8.3 1017 CRD repair room B R/B-4FL 3.6 C 3.6 866 FPC heat exchanger room R/B-3FL 4.8 A 5.4 807 CUW heat exchanger room R/B-2FL 4.0 A 0.9 633 CUW auxiliary pump room R/B-2FL 3.5 A 2.6 875 Around RHR pump R/B-BFL 6.0 A 1.7 902 Equipment drain sump pump R/B-BFL 3.5 A 4.4 989 Around feed-water nozzle PCV-3FL 3.0 A 2.3 734 Around SRV A PCV-2FL 18.0 A 15.9 1008 Around RHR/CUW piping PCV-2FL 90.0 C 83.4 860 Around PLR ring header PCV-2FL 25.0 C 11.5 736 Around PLR moter PCV-1FL 9.0 A 6.9 1032 Around MSIV PCV-1FL 6.0 A 4.7 879 Machine loading hatch front PCV-1FL 11.0 A 7.3 1053 Pedestal inside PCV-BFL 20.0 A 16.2 1312 Around floor drain sump pump PCV-BFL 8.0 A 4.2 950 CVCS, chemical and volume control system; RHR, residual heat removal system; SG, steam generator; CRD, control rod drive; FPC, fuel pool cooling and cleanup system; CUW, reactor water cleanup system; SRV, safety relief valve; PLR, primary loop recirculation system; MSIV, main steam isolation valve. aA: 3-inch spherical NaI, B: 2-inch spherical NaI, C: 1-inch spherical NaI, D: 1-inch diameter cylindrical NaI. Note: Reproduced and translated by the author based on Figure 3.4.1 and Table 3.4.3 in REA (2019)(21). The original was Figure A and Table 1 in EPCJCR (1983).(19) Open in new tab Table 3 Gamma-ray direction during PIM. (1) PWR . Survey spot Mean gamma-ray energy (keV) Direction component (%) in Northern hemisphere 1. Top 2. Top front 3. Top left 4. Top back 5. Top right 6. Front 7. Left 8. Back 9. Right Spent fuel pit 653 0 0 0 0 0 17 47 36 0 Waste liquid evaporator room 1225 0 18 0 0 0 53 15 14 0 CVCS non-regeneration cooler room 851 0 0 0 0 24 63 3 0 10 RHR cooler room 836 37 11 11 9 0 2 26 4 0 RHR piping area A 920 10 0 0 2 16 16 6 44 5 RHR piping area B 845 19 9 9 25 0 34 0 3 0 RHR pump room 1113 10 21 8 0 1 51 9 0 0 5FL inside C/V 793 13 31 16 3 0 25 13 0 0 Loop room entrance 661 15 31 9 7 0 29 0 2 7 Beside the SG handhole 685 0 2 0 0 0 98 0 0 0 Below the SG manhole 877 78 4 7 0 3 1 7 0 1 Beside the SG barrier 827 2 1 5 0 14 9 45 1 26 Pressurizer 780 0 50 4 15 0 9 1 21 0 Reactor cooler pump 767 — — — — — — — — — (2) BWR Survey spot Mean gamma-ray energy (keV) Direction component (%) in northern hemisphere 1. Top 2. Top front 3. Top left 4. Top back 5. Top right 6. Front 7. Left 8. Back 9. Right Condensate water filter room 859 0 0 0 0 0 - 0 0 - Condensate demineralizer room 771 0 2 76 0 0 0 6 13 2 Waste disposal pump room 992 0 13 11 0 15 59 0 0 2 Waste disposal tank room 1097 0 60 5 1 4 21 6 0 4 Fuel inspection area 921 0 0 0 0 0 — 0 0 — 5FL inside R/B 382 4 15 0 0 0 22 22 37 0 Reactor well inside 1017 4 1 0 0 23 45 11 3 12 CRD repair room B 866 0 0 0 0 0 0 31 4 65 FPC heat exchanger room 807 13 17 3 13 10 31 0 5 9 CUW heat exchanger room 633 0 53 5 0 9 22 0 9 1 CUW auxiliary pump room 875 42 0 0 20 3 0 0 20 14 Around RHR pump 902 0 44 0 0 0 33 0 0 22 Equipment drain sump pump 989 12 0 10 19 19 0 10 29 0 Around feed-water nozzle 734 8 4 16 0 16 12 44 0 0 Around SRV A 1008 2 0 17 4 4 5 47 22 0 Around RHR/CUW piping 860 0 6 2 0 0 56 0 7 28 Around PLR ring header 736 2 0 5 0 1 11 81 0 0 Around PLR moter 1032 11 2 25 2 10 0 36 14 0 Around MSIV 879 0 25 4 0 0 69 1 0 1 Machine loading hatch front 1053 42 5 20 0 14 1 5 0 13 Pedestal inside 1312 0 59 0 23 12 2 3 0 3 Around floor drain sump pump 950 10 20 0 0 0 61 9 0 0 (1) PWR . Survey spot Mean gamma-ray energy (keV) Direction component (%) in Northern hemisphere 1. Top 2. Top front 3. Top left 4. Top back 5. Top right 6. Front 7. Left 8. Back 9. Right Spent fuel pit 653 0 0 0 0 0 17 47 36 0 Waste liquid evaporator room 1225 0 18 0 0 0 53 15 14 0 CVCS non-regeneration cooler room 851 0 0 0 0 24 63 3 0 10 RHR cooler room 836 37 11 11 9 0 2 26 4 0 RHR piping area A 920 10 0 0 2 16 16 6 44 5 RHR piping area B 845 19 9 9 25 0 34 0 3 0 RHR pump room 1113 10 21 8 0 1 51 9 0 0 5FL inside C/V 793 13 31 16 3 0 25 13 0 0 Loop room entrance 661 15 31 9 7 0 29 0 2 7 Beside the SG handhole 685 0 2 0 0 0 98 0 0 0 Below the SG manhole 877 78 4 7 0 3 1 7 0 1 Beside the SG barrier 827 2 1 5 0 14 9 45 1 26 Pressurizer 780 0 50 4 15 0 9 1 21 0 Reactor cooler pump 767 — — — — — — — — — (2) BWR Survey spot Mean gamma-ray energy (keV) Direction component (%) in northern hemisphere 1. Top 2. Top front 3. Top left 4. Top back 5. Top right 6. Front 7. Left 8. Back 9. Right Condensate water filter room 859 0 0 0 0 0 - 0 0 - Condensate demineralizer room 771 0 2 76 0 0 0 6 13 2 Waste disposal pump room 992 0 13 11 0 15 59 0 0 2 Waste disposal tank room 1097 0 60 5 1 4 21 6 0 4 Fuel inspection area 921 0 0 0 0 0 — 0 0 — 5FL inside R/B 382 4 15 0 0 0 22 22 37 0 Reactor well inside 1017 4 1 0 0 23 45 11 3 12 CRD repair room B 866 0 0 0 0 0 0 31 4 65 FPC heat exchanger room 807 13 17 3 13 10 31 0 5 9 CUW heat exchanger room 633 0 53 5 0 9 22 0 9 1 CUW auxiliary pump room 875 42 0 0 20 3 0 0 20 14 Around RHR pump 902 0 44 0 0 0 33 0 0 22 Equipment drain sump pump 989 12 0 10 19 19 0 10 29 0 Around feed-water nozzle 734 8 4 16 0 16 12 44 0 0 Around SRV A 1008 2 0 17 4 4 5 47 22 0 Around RHR/CUW piping 860 0 6 2 0 0 56 0 7 28 Around PLR ring header 736 2 0 5 0 1 11 81 0 0 Around PLR moter 1032 11 2 25 2 10 0 36 14 0 Around MSIV 879 0 25 4 0 0 69 1 0 1 Machine loading hatch front 1053 42 5 20 0 14 1 5 0 13 Pedestal inside 1312 0 59 0 23 12 2 3 0 3 Around floor drain sump pump 950 10 20 0 0 0 61 9 0 0 Note: (1) Reproduced and translated by the author based on Table 3.4.3 in REA (2019)(21). The original was Figure A and Table 1 in EPCJCR (1983)(19). (2) Unit of length: mm, φ: diameter, R: radius in the diagram at bottom left. The number in the direction component columns corresponded to that in the diagram at bottom right. (3) The values in bold represented the largest in respective rows. Open in new tab Table 3 Gamma-ray direction during PIM. (1) PWR . Survey spot Mean gamma-ray energy (keV) Direction component (%) in Northern hemisphere 1. Top 2. Top front 3. Top left 4. Top back 5. Top right 6. Front 7. Left 8. Back 9. Right Spent fuel pit 653 0 0 0 0 0 17 47 36 0 Waste liquid evaporator room 1225 0 18 0 0 0 53 15 14 0 CVCS non-regeneration cooler room 851 0 0 0 0 24 63 3 0 10 RHR cooler room 836 37 11 11 9 0 2 26 4 0 RHR piping area A 920 10 0 0 2 16 16 6 44 5 RHR piping area B 845 19 9 9 25 0 34 0 3 0 RHR pump room 1113 10 21 8 0 1 51 9 0 0 5FL inside C/V 793 13 31 16 3 0 25 13 0 0 Loop room entrance 661 15 31 9 7 0 29 0 2 7 Beside the SG handhole 685 0 2 0 0 0 98 0 0 0 Below the SG manhole 877 78 4 7 0 3 1 7 0 1 Beside the SG barrier 827 2 1 5 0 14 9 45 1 26 Pressurizer 780 0 50 4 15 0 9 1 21 0 Reactor cooler pump 767 — — — — — — — — — (2) BWR Survey spot Mean gamma-ray energy (keV) Direction component (%) in northern hemisphere 1. Top 2. Top front 3. Top left 4. Top back 5. Top right 6. Front 7. Left 8. Back 9. Right Condensate water filter room 859 0 0 0 0 0 - 0 0 - Condensate demineralizer room 771 0 2 76 0 0 0 6 13 2 Waste disposal pump room 992 0 13 11 0 15 59 0 0 2 Waste disposal tank room 1097 0 60 5 1 4 21 6 0 4 Fuel inspection area 921 0 0 0 0 0 — 0 0 — 5FL inside R/B 382 4 15 0 0 0 22 22 37 0 Reactor well inside 1017 4 1 0 0 23 45 11 3 12 CRD repair room B 866 0 0 0 0 0 0 31 4 65 FPC heat exchanger room 807 13 17 3 13 10 31 0 5 9 CUW heat exchanger room 633 0 53 5 0 9 22 0 9 1 CUW auxiliary pump room 875 42 0 0 20 3 0 0 20 14 Around RHR pump 902 0 44 0 0 0 33 0 0 22 Equipment drain sump pump 989 12 0 10 19 19 0 10 29 0 Around feed-water nozzle 734 8 4 16 0 16 12 44 0 0 Around SRV A 1008 2 0 17 4 4 5 47 22 0 Around RHR/CUW piping 860 0 6 2 0 0 56 0 7 28 Around PLR ring header 736 2 0 5 0 1 11 81 0 0 Around PLR moter 1032 11 2 25 2 10 0 36 14 0 Around MSIV 879 0 25 4 0 0 69 1 0 1 Machine loading hatch front 1053 42 5 20 0 14 1 5 0 13 Pedestal inside 1312 0 59 0 23 12 2 3 0 3 Around floor drain sump pump 950 10 20 0 0 0 61 9 0 0 (1) PWR . Survey spot Mean gamma-ray energy (keV) Direction component (%) in Northern hemisphere 1. Top 2. Top front 3. Top left 4. Top back 5. Top right 6. Front 7. Left 8. Back 9. Right Spent fuel pit 653 0 0 0 0 0 17 47 36 0 Waste liquid evaporator room 1225 0 18 0 0 0 53 15 14 0 CVCS non-regeneration cooler room 851 0 0 0 0 24 63 3 0 10 RHR cooler room 836 37 11 11 9 0 2 26 4 0 RHR piping area A 920 10 0 0 2 16 16 6 44 5 RHR piping area B 845 19 9 9 25 0 34 0 3 0 RHR pump room 1113 10 21 8 0 1 51 9 0 0 5FL inside C/V 793 13 31 16 3 0 25 13 0 0 Loop room entrance 661 15 31 9 7 0 29 0 2 7 Beside the SG handhole 685 0 2 0 0 0 98 0 0 0 Below the SG manhole 877 78 4 7 0 3 1 7 0 1 Beside the SG barrier 827 2 1 5 0 14 9 45 1 26 Pressurizer 780 0 50 4 15 0 9 1 21 0 Reactor cooler pump 767 — — — — — — — — — (2) BWR Survey spot Mean gamma-ray energy (keV) Direction component (%) in northern hemisphere 1. Top 2. Top front 3. Top left 4. Top back 5. Top right 6. Front 7. Left 8. Back 9. Right Condensate water filter room 859 0 0 0 0 0 - 0 0 - Condensate demineralizer room 771 0 2 76 0 0 0 6 13 2 Waste disposal pump room 992 0 13 11 0 15 59 0 0 2 Waste disposal tank room 1097 0 60 5 1 4 21 6 0 4 Fuel inspection area 921 0 0 0 0 0 — 0 0 — 5FL inside R/B 382 4 15 0 0 0 22 22 37 0 Reactor well inside 1017 4 1 0 0 23 45 11 3 12 CRD repair room B 866 0 0 0 0 0 0 31 4 65 FPC heat exchanger room 807 13 17 3 13 10 31 0 5 9 CUW heat exchanger room 633 0 53 5 0 9 22 0 9 1 CUW auxiliary pump room 875 42 0 0 20 3 0 0 20 14 Around RHR pump 902 0 44 0 0 0 33 0 0 22 Equipment drain sump pump 989 12 0 10 19 19 0 10 29 0 Around feed-water nozzle 734 8 4 16 0 16 12 44 0 0 Around SRV A 1008 2 0 17 4 4 5 47 22 0 Around RHR/CUW piping 860 0 6 2 0 0 56 0 7 28 Around PLR ring header 736 2 0 5 0 1 11 81 0 0 Around PLR moter 1032 11 2 25 2 10 0 36 14 0 Around MSIV 879 0 25 4 0 0 69 1 0 1 Machine loading hatch front 1053 42 5 20 0 14 1 5 0 13 Pedestal inside 1312 0 59 0 23 12 2 3 0 3 Around floor drain sump pump 950 10 20 0 0 0 61 9 0 0 Note: (1) Reproduced and translated by the author based on Table 3.4.3 in REA (2019)(21). The original was Figure A and Table 1 in EPCJCR (1983)(19). (2) Unit of length: mm, φ: diameter, R: radius in the diagram at bottom left. The number in the direction component columns corresponded to that in the diagram at bottom right. (3) The values in bold represented the largest in respective rows. Open in new tab Thierry-Chef et al. (2001)(13) described a method to assess the proportion of the dose from photons in three energy ranges (<100, 100–300, ≥300 keV) using the responses under filters of a multi-element dosemeter and stated that the experimental, simulated data provided a good estimate of the proportion of dose from photons below 100 keV, the most critical for dosemeter response. Then the method was applied to personnel readings in one facility of Saclay, France, confirming the experts’ estimation. Thus, the expert’s estimation results of the IARC study assumption were supported by the experiment at Saclay. The authors(13) also described that the results of the Saclay analyses were consistent with estimates of dose distribution with energy in the workplace carried out in the UK and USA. Japanese epidemiological study The Japanese Epidemiological Study on Low-Dose Radiation Effects (J-EPISODE), funded by the Nuclear Regulation Authority (NRA), formerly by the Ministry of Education, Culture, Sports, Science and Technology (MEXT), has been conducted by the Radiation Effects Association (REA) since 1990 and analyzed health effects in association with radiation exposure evaluated in personal dose equivalent Hp(10)(14). However, in the above-mentioned, internationally evaluated radiation epidemiological studies, organ-absorbed dose is mainly used for the evaluation of morbidity and mortality due to cancer. In order for J-EPISODE to be compared and evaluated internationally in the future, it is indispensable to use organ-absorbed dose. In addition, cancer incidence data since 2016 have become available by the National Cancer Registry(15). These conditions have enhanced J-EPISODE reconstruct organ-absorbed dose, and the Expert Committee on Reconstruction of Organ Dose was set up within REA during fiscal year 2017–2018. Aim of the study The reconstruction of organ dose necessitates information on the photon energy and geometry distribution of the exposed population. The IARC study assumption seemed to be consistent with common knowledge based on the practical experience of radiation control staff in Japan. However, no document clearly stating working environment compatible with the IARC study assumption had been available in the public domain. In order to verify the validity of the IARC study assumption also in Japan, a literature survey was conducted to review documents on working environment, such as photon energy distribution and geometry distribution of Japan’s NPPs, which was also pointed out by the Expert Committee. The present paper describes the results of a literature survey on energy distribution and geometry distribution in Japan’s NPPs and a supplementary analysis of the data. Reflecting the above result of literature survey, conversion factor from dosemeter reading to air kerma for nuclear worker for further conversion from air kerma to organ-absorbed dose was constructed in the preceding paper of Furuta et al. (2020)(16). MATERIALS AND METHODS The estimation of energy distribution and direction distribution of gamma ray was an important research item because it was the basic information for the evaluation of the personal dosemeter characteristics under actual working environment and the dose equivalent distribution in the body. Features of Japanese NPP The reactor type of NPPs operated in Japan was a boiling water reactor (BWR) or a pressurized water reactor (PWR). There were 50 operating NPPs as of March 2013. Of these, 26 plants were BWR and 24 were PWR(17). In Japan, periodical inspection by the successive regulatory authorities was implemented within at most 13 months from the previous one, and in many cases, nuclear operator conducted refueling, disassembling, maintenance and improvement work for dose reduction during shutdown period. Oumi et al. (2011)(18) reported that the operation of the upper limit of regulation about 13 months and periodical inspection outage about 80 days were carried out in Japan and that the exposure dose during the periodical inspection usually contributed to 80–90% of the total annual dose. The authors(18) also described the features of Japan’s working environment in comparison with foreign countries, especially the USA, as follows: the duration of plant operation was shorter, the duration of inspection activities was longer and the number of workers during outage was larger. In this connection, the term of ‘periodical inspection’ was hereafter referred to as ‘periodical inspection and maintenance (PIM)’. Disclosure of survey result Regarding literature survey results, the 10 major electric power companies agreed to disclose the report of electric power companies’ joint commissioned research (hereafter called EPCJCR)(19, 20) to REA and allowed REA to list the report as a reference and also to reproduce several tables and figures in the Expert Committee’s report, which was compiled in 2019, submitted as one of deliverables to NRA and then placed in the public domain(21), in order to enable a sharing of the basic information of working environment with stakeholders, such as researchers, government officials and radiation control staff of NPP. Literature survey During a literature survey, it was revealed that an energy spectrum analysis of the light-water reactor in Japan was actively conducted in the 1980s, when introduction of the concept of effective dose equivalent recommended by ICRP Publ. 26(22) was considered. Since drastic changes were expected in the field of radiation protection at that time, it was considered that, in anticipation of the changes, proactive research activities had been carried out, which seemed also aggressive from a modern perspective. Figure 1 Open in new tabDownload slide Example of gamma-ray direction measurement apparatus; NaI detector and lead shield container cap with slits. Cited Figure 1 in CRIEPI (1985)(23). Unit of length: mm, φ: diameter While conducting the literature survey, we arrived at the publicly accessible report of the Central Research Institute of Electric Power Industry (CRIEPI) (1985)(23), which was a compilation of the result of technical studies on measurement method of direction distribution and energy distribution of radiation. With that as a clue, it was found that the 10 major electric power companies jointly conducted measurements on gamma-ray energy distribution and incident direction distribution at several NPPs in the 1980s, using the measurement method described in CRIEPI(23). One of the EPCJCR was the survey during PIM(19), the other was the survey during operation(20). These two survey reports were disclosed to REA upon request. However, the energy distribution during PIM described in EPCJCR (1983)(19) was found only in the form of line charts of pulse-height count (PHC) data, the result of which could not be compared directly with the IARC study assumption. As a result of inquiring at each electric power company about the existence of investigation data on energy distribution during PIM, it was found that Tokyo Electric Power Company (TEPCO) holdings conserved the result of TEPCO commissioned survey during PIM(24), which REA also applied for disclosure. EPCJCR survey method during PIM Literature of EPCJCR (1983)(19) investigated the energy distribution and incident direction distribution of gamma rays in the working area during PIM, exposure control during which was very important. As for the purpose of the survey(19), the report described as follows: In line with the external exposure control of various workers at NPP, it was necessary to make an evaluation based on the determination of radiation field under the working environment. In 1981, the basic study on the related information and the preliminary test at the site of PWR were conducted, and in 1982, on-site evaluation of external exposure dose using the measurement apparatus was conducted on the main working areas during PIM at representative plants of PWR and BWR. The work area investigated in the survey(19) was 13 spots in PWR and 22 spots in BWR. In PWR, six spots in the reactor auxiliary building (A/B), two spots in the containment vessel (C/V) and five spots in the loop room were selected. In addition, in BWR, two spots in the turbine building (T/B), two spots in the radioactive waste disposal building (RW/B), nine spots in the reactor building (R/B) and nine spots in the primary containment vessel (PCV) were included in the survey. The report(19) stated that the selected survey spots were well-represented because almost all the major works during PIM were performed there, or in the similar work environment. Measurement apparatus for energy distribution and direction distribution In order to measure the energy distribution and direction distribution of gamma rays at NPP where the air dose rate spread widely, a measurement apparatus using NaI detector was manufactured(19, 20, 23, 24). The apparatus was structured to be shielded by a lead material in order to reduce the influence of the background radiation, and a lead head portion with openable slits was provided on it so that gamma rays from a specific direction could be separated and measured. The slits of the lead container were provided at a total of nine positions in the northern hemisphere, at the north pole, at four equal division points on the 45° north circumference, and at four equal division points on the equator. Figure 1 is an example of a measurement apparatus using 2-inch spherical NaI(23). Regarding direction distribution, the spectral difference was measured by opening and closing the lead shielding plug of each slit. As for energy distribution, a PHC was measured without lead shield container cap on NaI detector. Then, the dose rate, the mean energy and the energy distribution of gamma rays could be calculated from this PHC data by applying the response matrix method. The NaI detector of 3-inch spherical type was mainly used, but in the high dose rate field, 2-inch spherical type or 1-inch spherical type was also used. For spectrum measurement, a portable pulse-height analyzer was employed(23). TEPCO survey method during PIM TEPCO conducted the survey on the radiation distribution of various working areas at Fukushima Daiichi Nuclear Power Station (BWR) in 1983–1984(24). The survey work area was the whole area of Unit Three and the fifth floor of the R/B in Unit One. The measurement method of the energy distribution of the gamma rays was the same as that of EPCJCR (1983)(19). In addition to the PHC data, the analysis results of the gamma-ray intensity and the dose distribution by energy were listed in detail in tables and figures for each survey spot. Table of the cumulative dose contribution rate by energy at 100 keV band from 0 keV to 3000 keV was available for each survey spot. Thus, the value in the 200–300 keV band of the table indicated the proportion of dose <300 keV. EPCJCR survey method during operation The EPCJCR (1986)(20) implemented in 1984–1986 was intended to determine the dose rate distribution and energy distribution of high energy gamma rays in NPP during operation, when the radiation distribution status was regarded as different from that during PIM. Gamma-ray energy distribution was measured at a total of 19 spots in the selected two plants from BWR, and at a total of nine spots in the selected two plants from PWR. Although PWR survey measured inside C/V, BWR survey did not cover inside C/V because inert gas filled during operation. Direction distribution of gamma rays was not investigated. RESULTS EPCJCR survey result during PIM Literature of EPCJCR (1983)(19) described as follows: The main radiation type in each work area was gamma rays, and the exposure rate was at least 0.02 mR/H (ambient dose equivalent rate: 0.2 μSv/h) and at most 90 mR/H (0.9 mSv/h), as shown in Table 2. It was below 40 mR/H (0.4 mSv/h) in most work areas(19, 21). Although the main radiation source during PIM was 60Co (gamma-ray energies: 1.17 MeV and 1.33 MeV), the report(19) stated that there were many work areas where the mean gamma-ray energy was in the range of 800–1000 keV due to the influence of scattering components, etc. Geometry distribution during PIM According to Table 3, the actual working environment was not recognized as simple source distribution such as single point source. In many cases, the source direction in which the maintenance worker mainly exposed to radiation was found to be front or upper front. Table 3 shows the results when the lead shield container with slits was left standing in the main source direction. In other words, it meant the exposure geometry when the worker was standing stationary at the maintenance spot toward the main source. The mean sum value of the column of ‘6. Front’ and ‘2. Top front’ of Table 3, which was assumed as AP geometry, was approximately 41% (interquartile range (IQR): 10–70%)1. The result supported that the proportion of AP was set up to an average of 50% and range 10–80% in IARC study assumption. In addition to this, a video shooting of the actual worker’s motion during main jobs was implemented to analyze the worker’s ROT movements(19). The survey stated that the worker’s movements showed the individuality such as right-handedness, fatigue, etc., and the rotation component was large even when the work was done in a specific direction. According to Table 4, the direction component of ‘Front’ by ROT motion analysis averaged 37%. It was found that even though the main source was located stationary in front of the measurement apparatus, the ROT movement of the actual worker contributed to increase the ratio of ROT or ISO in the exposure geometry. Considering that there were components of top front, top left, top back and top right in Table 2, it was appropriate for the worker’s exposure geometry to be regarded as ISO rather than ROT. Energy distribution during PIM Figure 2 displays an example of gamma-ray energy spectrum measurement for each of four representative working areas of PWR (upper) and BWR (lower) during PIM. The X-axis of each chart was gamma-ray energy (MeV) from 0 to 1.6 MeV, whereas the measurement was performed up to 3 MeV. The Y-axis was the common logarithm of the counting rate (PWR: counts/40 sec, BWR: counts/80 sec). That is, the figure represented gamma-ray PHC from NaI detector. However, neither a table nor a chart showing the energy distribution of the dose was included in the report(19). Figure 2 Open in new tabDownload slide PHC of photon energy during PIM at PWR and BWR plant. Cited Figure 3.4.5 in REA (2019)(21). The original was Figure 4 in EPCJCR (1983)(19), written in Japanese. The caption was ‘Figure 4. Examples of measurement of gamma-ray energy spectrum’. The X-axis was ‘Gamma-rays energy (MeV)’, representing 0–1.5 MeV. The upper four line-chars were at PWR and the lower four at BWR. The Y-axis scale represented from 102 to 106. The unit of Y-axis at PWR was ‘Count rate (counts/40 sec)’ and that at BWR was ‘Count rate (counts/80 sec)’. Each chart had two lines, the upper of which was the measurement result without lead shield container cap on NaI detector, and the lower of which was the measurement result with the lead shielding plug of a specific slit being open. The survey spots at PWR were, from the left, RHR pump room, primary coolant loop room entrance, below the SG manhole and the fifth floor inside C/V, whereas those at BWR were radioactive waste disposal tank room, pedestal inside, reactor well inside and triangle corner in the reactor well. Table 4 Rotational movement analysis of real workers by video shooting during PIM. Survey spot . Work description . Direction component when the phantom installation direction was front (%) . Front (0°) . Front right (45°) . Right (90°) . Back right (135°) . Back (180°) . Back left (225°) . Left (270°) . Front left (315°) . PWR Spent fuel pit New fuel transportation 24 18 18 7 6 3 17 3 RHR pump room Impeller installation 32 23 14 1 0 1 6 17 5FL inside C/V Fuel support pin replacement 49 5 8 6 5 14 7 2 Beside the SG handhole Lid closing 15 1 3 0 0 0 41 37 Below the SG manhole Eddy current testing 40 17 11 2 2 1 9 15 Pressurizer Inspection 45 3 1 0 1 2 16 28 Reactor cooler pump Inspection 34 29 23 7 3 1 0 1 BWR Condensate water filter room Filter out and transportation 5 10 7 8 13 33 10 11 Condensate demineralizer room Inspection 23 10 13 1 7 0 15 27 Fuel inspection area Refueling 48 12 10 0 0 0 11 16 5FL inside R/B PCV head on 36 15 2 2 4 4 11 21 Reactor well inside Decontamination 15 9 20 10 19 7 9 6 CRD repair room Overhaul inspection 22a 15 8 7 9 9 9 16 Around SRV Loading and assembly restoration 30b 5 1 1 3 3 12 42 RHR pump room Inspection 68 10 9 0 1 2 3 4 PLR pump Mechanical seal replacement 84 0 0 0 1 3 2 6 Pedestal inside CRD recovery 60 8 9 7 0 0 1 12 Survey spot . Work description . Direction component when the phantom installation direction was front (%) . Front (0°) . Front right (45°) . Right (90°) . Back right (135°) . Back (180°) . Back left (225°) . Left (270°) . Front left (315°) . PWR Spent fuel pit New fuel transportation 24 18 18 7 6 3 17 3 RHR pump room Impeller installation 32 23 14 1 0 1 6 17 5FL inside C/V Fuel support pin replacement 49 5 8 6 5 14 7 2 Beside the SG handhole Lid closing 15 1 3 0 0 0 41 37 Below the SG manhole Eddy current testing 40 17 11 2 2 1 9 15 Pressurizer Inspection 45 3 1 0 1 2 16 28 Reactor cooler pump Inspection 34 29 23 7 3 1 0 1 BWR Condensate water filter room Filter out and transportation 5 10 7 8 13 33 10 11 Condensate demineralizer room Inspection 23 10 13 1 7 0 15 27 Fuel inspection area Refueling 48 12 10 0 0 0 11 16 5FL inside R/B PCV head on 36 15 2 2 4 4 11 21 Reactor well inside Decontamination 15 9 20 10 19 7 9 6 CRD repair room Overhaul inspection 22a 15 8 7 9 9 9 16 Around SRV Loading and assembly restoration 30b 5 1 1 3 3 12 42 RHR pump room Inspection 68 10 9 0 1 2 3 4 PLR pump Mechanical seal replacement 84 0 0 0 1 3 2 6 Pedestal inside CRD recovery 60 8 9 7 0 0 1 12 aThe direction of the tank was taken as front. bThe reactor tangential direction was taken as front. Note: Reproduced and translated by the author based on Table 3.4.4 in REA (2019)(21). The original was Table 6 in EPCJCR (1983)(19). Open in new tab Table 4 Rotational movement analysis of real workers by video shooting during PIM. Survey spot . Work description . Direction component when the phantom installation direction was front (%) . Front (0°) . Front right (45°) . Right (90°) . Back right (135°) . Back (180°) . Back left (225°) . Left (270°) . Front left (315°) . PWR Spent fuel pit New fuel transportation 24 18 18 7 6 3 17 3 RHR pump room Impeller installation 32 23 14 1 0 1 6 17 5FL inside C/V Fuel support pin replacement 49 5 8 6 5 14 7 2 Beside the SG handhole Lid closing 15 1 3 0 0 0 41 37 Below the SG manhole Eddy current testing 40 17 11 2 2 1 9 15 Pressurizer Inspection 45 3 1 0 1 2 16 28 Reactor cooler pump Inspection 34 29 23 7 3 1 0 1 BWR Condensate water filter room Filter out and transportation 5 10 7 8 13 33 10 11 Condensate demineralizer room Inspection 23 10 13 1 7 0 15 27 Fuel inspection area Refueling 48 12 10 0 0 0 11 16 5FL inside R/B PCV head on 36 15 2 2 4 4 11 21 Reactor well inside Decontamination 15 9 20 10 19 7 9 6 CRD repair room Overhaul inspection 22a 15 8 7 9 9 9 16 Around SRV Loading and assembly restoration 30b 5 1 1 3 3 12 42 RHR pump room Inspection 68 10 9 0 1 2 3 4 PLR pump Mechanical seal replacement 84 0 0 0 1 3 2 6 Pedestal inside CRD recovery 60 8 9 7 0 0 1 12 Survey spot . Work description . Direction component when the phantom installation direction was front (%) . Front (0°) . Front right (45°) . Right (90°) . Back right (135°) . Back (180°) . Back left (225°) . Left (270°) . Front left (315°) . PWR Spent fuel pit New fuel transportation 24 18 18 7 6 3 17 3 RHR pump room Impeller installation 32 23 14 1 0 1 6 17 5FL inside C/V Fuel support pin replacement 49 5 8 6 5 14 7 2 Beside the SG handhole Lid closing 15 1 3 0 0 0 41 37 Below the SG manhole Eddy current testing 40 17 11 2 2 1 9 15 Pressurizer Inspection 45 3 1 0 1 2 16 28 Reactor cooler pump Inspection 34 29 23 7 3 1 0 1 BWR Condensate water filter room Filter out and transportation 5 10 7 8 13 33 10 11 Condensate demineralizer room Inspection 23 10 13 1 7 0 15 27 Fuel inspection area Refueling 48 12 10 0 0 0 11 16 5FL inside R/B PCV head on 36 15 2 2 4 4 11 21 Reactor well inside Decontamination 15 9 20 10 19 7 9 6 CRD repair room Overhaul inspection 22a 15 8 7 9 9 9 16 Around SRV Loading and assembly restoration 30b 5 1 1 3 3 12 42 RHR pump room Inspection 68 10 9 0 1 2 3 4 PLR pump Mechanical seal replacement 84 0 0 0 1 3 2 6 Pedestal inside CRD recovery 60 8 9 7 0 0 1 12 aThe direction of the tank was taken as front. bThe reactor tangential direction was taken as front. Note: Reproduced and translated by the author based on Table 3.4.4 in REA (2019)(21). The original was Table 6 in EPCJCR (1983)(19). Open in new tab Trial estimation of energy distribution from PHC data Although analysis method of PHC data were described in the Appendix in the present paper, the result was described here. Reading the line chart of counting rate of gamma rays at an interval of 0.1 MeV, the gamma-ray energy distribution under a certain assumption was calculated as shown in Table 5. The proportion of dose of 0.1–0.3 MeV was a mean of 11% of eight survey spots (IQR: 4–13%, mean for PWR: 9%, BWR: 14%) and was found to be within the range expected by the IARC study assumption. TEPCO survey result on gamma-ray energy distribution during PIM Figure 3 shows the energy distribution at the 32 measurement spots in Unit Three, Fukushima Daiichi Nuclear Power Station except for the operation of PCV head off. The dose ratio of gamma rays with energy <300 keV showed the mean of 7.2% (IQR: 4.7–8.7%), and at most 18%, which were within the range envisioned by the IARC study assumption. Figure 3 Open in new tabDownload slide Gamma-ray energy distribution during PIM (TEPCO survey at Unit Three, Fukushima Daiichi Nuclear Power Station (BWR)). Cited Figure 3.4.7 in REA (2019)(21) and translated by the author. The original data were on the tables in TEPCO (1984)(24) On the other hand, the energy distribution when opening PCV head was measured at Unit One, Fukushima Daiichi Nuclear Power Station. At the time of PCV head off operation, the energy distribution change of the gamma ray was expected. Making the use of high sensitivity type 3-inch height, 3-inch diameter cylindrical NaI detector, continuous measurement of energy distribution was performed. The dose ratio of <300 keV was summarized by stage when PCV head was opened, as shown in Table 6. The dose ratio of <300 keV on the fifth floor of the R/B before opening PCV head was 13%, similar to the measurement results of Unit Three. As the opening work of the PCV head progressed, the mean energy value gradually decreased (not shown), whereas the dose ratio of <300 keV was at most 27%. The increased percentage of low energy gamma rays along with opening PCV head seemed to be due to the gamma rays from inside the reactor being scattered at the ceiling. When the well was filled full with water after completion of the PCV head off operation, the dose ratio of <300 keV returned to the value before the PCV head was opened. Table 5 Trial estimation result of gamma-ray energy distribution during PIM. Survey spot . . Proportion of dose of 0.1–0.3 MeV (%) . PWR RHR pump room 3.2 Primary coolant loop room entrance 14.1 Below the SG manhole 6.0 The fifth floor inside C/V 13.2 Mean 9 BWR Radioactive waste disposal tank room 4.0 Pedestal inside 2.7 Reactor well inside 9.5 Triangle corner in the reactor well 38.4 Mean 14 Mean of the eight survey spots 11 Survey spot . . Proportion of dose of 0.1–0.3 MeV (%) . PWR RHR pump room 3.2 Primary coolant loop room entrance 14.1 Below the SG manhole 6.0 The fifth floor inside C/V 13.2 Mean 9 BWR Radioactive waste disposal tank room 4.0 Pedestal inside 2.7 Reactor well inside 9.5 Triangle corner in the reactor well 38.4 Mean 14 Mean of the eight survey spots 11 Note: Cited Table 3.4.6 in REA (2019)(21) and translated by the author. The estimation method was described in the Appendix in the present paper. Open in new tab Table 5 Trial estimation result of gamma-ray energy distribution during PIM. Survey spot . . Proportion of dose of 0.1–0.3 MeV (%) . PWR RHR pump room 3.2 Primary coolant loop room entrance 14.1 Below the SG manhole 6.0 The fifth floor inside C/V 13.2 Mean 9 BWR Radioactive waste disposal tank room 4.0 Pedestal inside 2.7 Reactor well inside 9.5 Triangle corner in the reactor well 38.4 Mean 14 Mean of the eight survey spots 11 Survey spot . . Proportion of dose of 0.1–0.3 MeV (%) . PWR RHR pump room 3.2 Primary coolant loop room entrance 14.1 Below the SG manhole 6.0 The fifth floor inside C/V 13.2 Mean 9 BWR Radioactive waste disposal tank room 4.0 Pedestal inside 2.7 Reactor well inside 9.5 Triangle corner in the reactor well 38.4 Mean 14 Mean of the eight survey spots 11 Note: Cited Table 3.4.6 in REA (2019)(21) and translated by the author. The estimation method was described in the Appendix in the present paper. Open in new tab Table 6 Change of gamma-ray energy distribution during PCV head off (TEPCO survey) (beside the reactor well on the fifth floor in the R/B, Unit One, Fukushima Daiichi Nuclear Power Station (BWR)). Stages when opening PCV head . Proportion of dose <300 keV (%) . Before PCV head opening (Seven-spot mean) 12.5 The day before PCV head opening 7.6 Just before opening the PCV head 13.2 Lifting the PCV head in the reactor well 20.3 Putting the PCV head on the fifth floor 21.1 PCV head opened completely 27.4 Reactor well filled with water after moving the dryer (Two-spot mean) 11.0 Stages when opening PCV head . Proportion of dose <300 keV (%) . Before PCV head opening (Seven-spot mean) 12.5 The day before PCV head opening 7.6 Just before opening the PCV head 13.2 Lifting the PCV head in the reactor well 20.3 Putting the PCV head on the fifth floor 21.1 PCV head opened completely 27.4 Reactor well filled with water after moving the dryer (Two-spot mean) 11.0 Note: Cited Table 3.4.8 in REA (2019)(21) and translated by the author. The original data were on the tables in TEPCO (1984)(24). Open in new tab Table 6 Change of gamma-ray energy distribution during PCV head off (TEPCO survey) (beside the reactor well on the fifth floor in the R/B, Unit One, Fukushima Daiichi Nuclear Power Station (BWR)). Stages when opening PCV head . Proportion of dose <300 keV (%) . Before PCV head opening (Seven-spot mean) 12.5 The day before PCV head opening 7.6 Just before opening the PCV head 13.2 Lifting the PCV head in the reactor well 20.3 Putting the PCV head on the fifth floor 21.1 PCV head opened completely 27.4 Reactor well filled with water after moving the dryer (Two-spot mean) 11.0 Stages when opening PCV head . Proportion of dose <300 keV (%) . Before PCV head opening (Seven-spot mean) 12.5 The day before PCV head opening 7.6 Just before opening the PCV head 13.2 Lifting the PCV head in the reactor well 20.3 Putting the PCV head on the fifth floor 21.1 PCV head opened completely 27.4 Reactor well filled with water after moving the dryer (Two-spot mean) 11.0 Note: Cited Table 3.4.8 in REA (2019)(21) and translated by the author. The original data were on the tables in TEPCO (1984)(24). Open in new tab EPCJCR survey result during operation in BWR In the BWR during operation, there was a spot where gamma rays with much higher energy than 60Co were generated. The nuclides of 16N (half-life: 7.13 sec) and 15C (half-life: 2.4 sec) were found which emit high energy gamma rays (16N: 6.1 MeV and 15C: 5.3 MeV) while moving along the steam flow(20) However, it was concluded that the effects of high energy gamma rays from 16N and 15C were negligible during PIM, because such nuclides disappeared shortly after shutdown due to their short half-lives and were no more produced during PIM. Figure 4 displays the dose contribution rates by gamma-ray energy at the nine survey spots in Hamaoka Nuclear Power Station (BWR). The X-axis of each chart was gamma-ray energy (MeV), which was displayed 0–8 MeV at 0.2 MeV bands. The Y-axis represented the cumulative dose contribution rate of gamma rays above the energy at the indicated point. Therefore, assuming that the contribution rates of the 0.1 MeV point, the 0.3 MeV point and the 3 MeV point were a, b and c, respectively, the ratio of (a − b) and (b − c) meant the dose ratio of 0.1–0.3 MeV and 0.3–3 MeV. Figure 4 Open in new tabDownload slide Gamma-ray energy distribution during operation at BWR plant. Cited Figure 3.4.9 in REA (2019)(21). The original was Figure 3 in EPCJCR (1986)(20), written in Japanese. The caption was ‘Figure 3. Dose contribution rate of each energy of gamma rays at selected survey spots in Hamaoka Nuclear Power Plant (BWR)’. The X-axis was ‘Gamma-rays energy E (MeV)’ and the Y-axis was ‘Dose contribution rate of each energy of gamma rays (E > Ei); %’. The nine line-charts displayed respective dose contribution of survey spots; from upper left to right, MSIV room, low pressure turbine room exit, rare gas hold-up pipe room, high pressure turbine room entrance, low pressure heater room entrance, CUW pump room, high pressure turbine room exit, recombiner room and front of personal air lock. According to the results of reading the charts, the proportion of dose of 0.1–0.3 MeV was in the range of 4 to 10% (Mean 7%), indicating that the results were within an envisioned range of IARC study. EPCJCR survey result during operation in PWR During the operation of PWR, high-energy gamma rays from 16N and 15C were also measured. In addition, gamma rays with energy about 8 MeV, which was higher than that of 16N, were also detected. It was considered that such gamma rays were emitted from the 56Fe (n, γ) 57Fe neutron capture reaction, in case that 56Fe were contained in the reactor structural material and captured neutrons generated by fission of 235U. Therefore, such high gamma rays were observed only inside C/V and in front of its emergency air lock near the reactor(20). Table 7 Gamma-ray direction distribution based on the EPCJCR. Proportion of AP geometry (%) . During PIM . During operation . Assumption of IARC study . BWR (22 spots) . PWR (13 spots) . BWR . PWR . Mean 39 46 Not surveyed 50 IQR 4–72 16–62 — Min—Max 0–94 5–100 10–80 Proportion of AP geometry (%) . During PIM . During operation . Assumption of IARC study . BWR (22 spots) . PWR (13 spots) . BWR . PWR . Mean 39 46 Not surveyed 50 IQR 4–72 16–62 — Min—Max 0–94 5–100 10–80 Note: (1) The above figures based on the results when the lead shield container with slits was left standing in the main source direction. (2) Cited Table 3.4.11 in REA (2019)(21) and translated by the author. Open in new tab Table 7 Gamma-ray direction distribution based on the EPCJCR. Proportion of AP geometry (%) . During PIM . During operation . Assumption of IARC study . BWR (22 spots) . PWR (13 spots) . BWR . PWR . Mean 39 46 Not surveyed 50 IQR 4–72 16–62 — Min—Max 0–94 5–100 10–80 Proportion of AP geometry (%) . During PIM . During operation . Assumption of IARC study . BWR (22 spots) . PWR (13 spots) . BWR . PWR . Mean 39 46 Not surveyed 50 IQR 4–72 16–62 — Min—Max 0–94 5–100 10–80 Note: (1) The above figures based on the results when the lead shield container with slits was left standing in the main source direction. (2) Cited Table 3.4.11 in REA (2019)(21) and translated by the author. Open in new tab Table 8 Gamma-ray energy distribution based on the EPCJCR. Proportion of dose in 0.1–0.3 MeV (%) . During PIM . During operation . Assumption of IARC study . BWR (4 spots) . PWR (4 spots) . BWR (9 spots) . PWR (5 spots) . Mean 14 9 7 10 10 IQR 4–17 5–13 5–8 10–11 — Min—Max 3–38 3–14 4–10 3–15 5–20 Proportion of dose in 0.1–0.3 MeV (%) . During PIM . During operation . Assumption of IARC study . BWR (4 spots) . PWR (4 spots) . BWR (9 spots) . PWR (5 spots) . Mean 14 9 7 10 10 IQR 4–17 5–13 5–8 10–11 — Min—Max 3–38 3–14 4–10 3–15 5–20 Note: Cited Table 3.4.12 in REA (2019)(21) and translated by the author. Open in new tab Table 8 Gamma-ray energy distribution based on the EPCJCR. Proportion of dose in 0.1–0.3 MeV (%) . During PIM . During operation . Assumption of IARC study . BWR (4 spots) . PWR (4 spots) . BWR (9 spots) . PWR (5 spots) . Mean 14 9 7 10 10 IQR 4–17 5–13 5–8 10–11 — Min—Max 3–38 3–14 4–10 3–15 5–20 Proportion of dose in 0.1–0.3 MeV (%) . During PIM . During operation . Assumption of IARC study . BWR (4 spots) . PWR (4 spots) . BWR (9 spots) . PWR (5 spots) . Mean 14 9 7 10 10 IQR 4–17 5–13 5–8 10–11 — Min—Max 3–38 3–14 4–10 3–15 5–20 Note: Cited Table 3.4.12 in REA (2019)(21) and translated by the author. Open in new tab Figure 5 displays the dose contribution rates by energy of gamma rays at five survey spots in Mihama Power Station (PWR). Similar to the above Figure 4 of BWR, but the X-axis was displayed from 0 to 9 MeV at 0.2 MeV bands. The estimated proportion of dose 0.1–0.3 MeV ranged from 3 to 15% (mean 10%). The result in PWR during operation was also found to be almost within an envisioned range of IARC study. Figure 5 Open in new tabDownload slide Gamma-ray energy distribution during operation at PWR plant. Cited Figure 3.4.10 in REA (2019)(21). The original was Figure 5 in EPCJCR (1986)(20), written in Japanese. The caption was ‘Figure 5. Dose contribution rate of each energy of gamma rays at selected survey spots in Mihama Power Plant (PWR)’. The X-axis was ‘Gamma-rays energy E (MeV)’ and the Y-axis was ‘Dose contribution rate of each energy of gamma rays (E > Ei); %’. The five line-charts displayed respective dose contribution at survey spots; from upper to bottom, charging/safety injection pump room (A/B), spent fuel pit (A/B), emergency air lock (A/B), emergency air lock (C/V) and front of the in-core neutron monitoring system thimble tubes (C/V). Summary With regard to the gamma-ray incident direction distribution during PIM in Table 7, the AP component did not reach 50% with the stationary measurement apparatus. However, considering the movement of the actual worker by video shooting, the AP ratio of the exposure geometry was not considered inconsistent with the IARC study assumption. Despite a lack of data during operation, the direction distribution during operation was understood that it was the same as those during PIM. Table 8 summarizes the energy distribution of gamma rays at Japanese NPP(21). The proportion of dose in 100–300 keV was found to be within an envisioned range of IARC study. In the end, it was verified that the surveys were conducted to assess the energy spectrum and directions of incidence on workers and that those surveys demonstrate that both the spectrum and the direction of incidence measured are compatible with the IARC study assumption. DISCUSSIONS Estimation method of energy distribution The approach for estimating energy distribution differed between Thierry-Chef (2001)(13) and EPCJCR(19, 20). The former used the differences of the responses under filters of a multi-element dosemeter, which was worn by a worker, whereas the latter used PHC data from a NaI detector, which was placed stationary at a specific working area. Despite the different approaches, it was interesting that the both resulted in almost the same ratio of energy 100–300 keV and 300–3000 keV. Trial estimation of energy distribution from PHC data The gamma-ray energy distribution during PIM at TEPCO whose energy distribution was not based on the trial estimation, but derived directly from the tables listed in the survey report(24) was evaluated as being within an envisioned range of IARC study. In addition, the result of the trial estimation (Table 5) was almost the same as the result of TEPCO (Figure 3). Therefore, the trial method of estimating dose distribution by energy from PHC data was confirmed to be appropriate. Gamma rays above 3 MeV during operation Figures 4 and 5 show that a considerable portion of gamma rays >3 MeV was present during operation. However, since only a limited number of operators and radiation control staff entered the control area during operation, and the stay inside the control area was also in short time, the portion of exposed gamma rays >3 MeV was considered small. Representativeness of the survey result over a long period J-EPISODE has published analysis reports every 5 y since 1995. The fifth analysis of J-EPISODE targeted the dose data during 1957–2010, at an intermediate point of which the EPCJCR were conducted. Although the dose rate had dropped sharply in the 1980s as a result of the dose reduction measures, the reactor type, the radiation source and job description basically remained without a big change, suggesting that the survey results in the 1980s represented the whole period 1957–2010. That is, it turned out that there was appropriate in applying the energy and geometry assumption of IARC study to J-EPISODE. CONCLUSIONS The IARC study assumption on the energy and geometry distribution of photon exposure is fundamental information in estimating organ-absorbed dose from personal dosemeter reading. Verifying whether the IARC study assumption can be applied to Japanese workers in NPP will be crucial for the assessment of reconstructed organ-absorbed dose. As a result of the literature survey in the 1980s, it was found that there were reports of investigation by EPCJCR where electric power companies actually measured and assessed the energy spectrum and directions of incidence on workers at the site of NPP separately during PIM and during operation. The results of EPCJCR became the evidence that the IARC study assumption was applicable for J-EPISODE. The analysis of working environment of Japanese workers in NPP demonstrated appropriateness in applying the IARC study assumption for reconstructing organ-absorbed dose in J-EPISODE. These results in Japan also provide strong evidence to support the robustness and generality of the IARC study assumption, which was estimated based on the judgment of experts at nuclear facilities around the world. FUNDING This study was funded by the Nuclear Regulation Authority, Japan. ACKNOWLEDGMENTS The authors thank the 10 major electric power companies in Japan for disclosing the results of the EPCJCR and permitting them to be referred in the REA’s report. Without this disclosure, the present study would not hold in the first place. Mr Masami Ikai, Mr Atsuo Ito and Mr Noboru Ishizawa of REA, who all had worked at TEPCO, provided important information, based on their recall, on research period and research titles regarding the related EPCJCR. Dr Kenji Ishida, who had been in charge of conducting the EPCJCR, kindly commented on the survey method and the perspective of the survey results. Dr Norio Tsujimura of Japan Atomic Energy Agency provided guidance on a wide range of fields such as dosimetry, measurement method and interpretation of the results of the EPCJCR. Dr Michiya Sasaki of CRIEPI provided basic idea about estimating photon energy distribution from PHC data of NaI detector. CONFLICT OF INTEREST The authors declare no conflicts of interest associated with this manuscript. ABBREVIATIONS DEFINITIONS A/B, auxiliary building; BWR, boiling water reactor; C/V, containment vessel; CRD, control rod drive; CUW, reactor water cleanup system; CVCS, chemical and volume control system; D/W, dry well; FPC, fuel pool cooling and cleanup system; MSIV, main steam isolation valve; PCV, primary containment vessel; PLR, primary loop recirculation system; PWR, pressurized water reactor; R/B, reactor building; RCW, reactor building closed cooling water system; RHR, residual heat removal system; RW/B, radioactive waste disposal building; SG, steam generator; SRV, safety relief valve; T/B, turbine building. NOTE The above list was based on the Information Portal for the Fukushima Daiichi Accident Analysis and Decommissioning Activities. Available from: https://fdada.info/en/home2/abbrev_top2/abbrev_search-en/ (5 July 2020, date last accessed). Footnotes 1 One survey spot of reactor cooler pump in PWR and two spots of condensate water filter room and fuel inspection area in BWR were excluded because of no description of the results. References 1. International Commission on Radiological Protection . The 2007 recommendations of the international commission on radiological protection, ICRP publication 103 . Ann. ICRP 37 ( 2/4 ), 251 – 253 ( 2007 ). OpenURL Placeholder Text WorldCat 2. Thierry-Chef , I. et al. The 15-country collaborative study of cancer risk among radiation workers in the nuclear industry: study of errors in dosimetry . Radiat. Res. 167 , 380 – 395 ( 2007 ). Google Scholar Crossref Search ADS PubMed WorldCat 3. Vrijheid , M. , Cardis , E., Blettner , M., Gilbert , E., Hakama , M., Hill , C., Howe , G., Kaldor , J., Muirhead , C. R. and Veress , K. The 15-country collaborative study of cancer risk among radiation workers in the nuclear industry: design, epidemiological methods and descriptive results . Radiat. Res. 167 , 361 – 379 ( 2007 ). Google Scholar Crossref Search ADS PubMed WorldCat 4. Cardis , E. , Vrijheid , M., Blettner , M., Gilbert , E., Hakama , M., Hill , C., Howe , G., Kaldor , J., Muirhead , C. R. and Veress , K. The 15-country collaborative study of cancer risk among radiation workers in the nuclear industry: estimates of radiation-related cancer risks . Radiat. Res. 167 , 396 – 416 ( 2007 ). Google Scholar Crossref Search ADS PubMed WorldCat 5. Thierry-Chef , I. et al. Dose estimation for a study of nuclear workers in France, the United Kingdom and the United States of America: methods for the international nuclear workers study (INWORKS) . Radiat. Res. 183 , 632 – 642 ( 2015 ). Google Scholar Crossref Search ADS PubMed WorldCat 6. Hamra , G. B. et al. Cohort profile: the international nuclear workers study (INWORKS) . Int. J. Epidemiol. 45 , 693 – 699 ( 2016 ). Google Scholar Crossref Search ADS PubMed WorldCat 7. Richardson , D. B. , Cardis, E., Daniels, R. D., Gillies, M., O'Hagan, J. A., Hamra, G. B., Haylock, R., Laurier, D., Leuraud, K., Moissonnier, M. et al. Risk of cancer from occupational exposure to ionizing radiation: retrospective cohort study of workers in France, the United Kingdom, and the United States (INWORKS) . BMJ 351 , h5359 ( 2015 ). Google Scholar Crossref Search ADS PubMed WorldCat 8. Leuraud , K. , Richardson, D. B., Cardis, E., Daniels, R. D., Gillies, M., O'Hagan, J. A., Hamra, G. B., Haylock, R., Laurier, D., Moissonnier, M. et al. Ionising radiation and risk of death from leukaemia and lymphoma in radiation-monitored workers (INWORKS): an international cohort study . Lancet Haematol . 2 , e276 – e281 ( 2015 ). Google Scholar Crossref Search ADS PubMed WorldCat 9. Gilbert , E. , Sokolnikov , M. E., Preston , D. L., Schonfeld , S. J., Schadilov , A. E., Vasilenko , E. K. and Koshumikova , N. A. Lung cancer risks from plutonium: an updated analysis of data from the Mayak worker cohort . Radiat. Res. 179 , 332 – 342 ( 2013 ). Google Scholar Crossref Search ADS PubMed WorldCat 10. Preston , D. L. , Ron , E., Tokuoka , S., Funamoto , S., Nishi , N., Soda , M., Mabuchi , K. and Kodama , K. Solid cancer incidence in atomic bomb survivors: 1958-1998 . Radiat. Res. 168 ( 1–64 ) ( 2007 ). Google Scholar OpenURL Placeholder Text WorldCat 11. Ozasa , K. , Shimizu , Y., Suyama , A., Kasagi , F., Midori , S., Grant , E. J., Sakata , R., Sugiyama , H. and Kodama , K. Studies of the mortality of atomic bomb survivors, report 14, 1950-2003: an overview of cancer and noncancer diseases . Radiat. Res. 177 , 229 – 243 ( 2012 ). Google Scholar Crossref Search ADS PubMed WorldCat 12. Grant , E. J. et al. Solid cancer incidence among the life span study of atomic bomb survivors: 1958-2009 . Radiat. Res. 187 , 513 – 537 ( 2017 ). Google Scholar Crossref Search ADS PubMed WorldCat 13. Thierry-Chef , I. , Cardis , E., Ciampi , A., Delacroix , D., Marshall , M., Amoros , E. and Bermann , F. A method to assess predominant energies of exposure in a nuclear research centre – Saclay (France) . Radiat. Prot. Dosim. 94 , 215 – 225 ( 2001 ). Google Scholar Crossref Search ADS WorldCat 14. Kudo , S. , Yoshimoto , K., Furuta , H., Inoue , K., Fukushi , M. and Kasagi , F. Occupational radiation exposure and leukemia mortality among nuclear workers in Japan: J-EPISODE, 1991–2010 . Jpn. J. Health. Phys. 53 , 146 – 153 ( 2018 ). Google Scholar Crossref Search ADS WorldCat 15. Matsuda , T. and Sobue , T. Recent trends in population-based cancer registries in Japan: the act on promotion of cancer registries and drastic changes in the historical registry . Int. J. Clin. Oncol. 20 , 11 – 20 ( 2015 ). Google Scholar Crossref Search ADS PubMed WorldCat 16. Furuta , H. , Tsujimura , N., Nishide , A., Kudo , S. and Saigusa , S. Conversion factor from dosemeter reading to air kerma for nuclear worker using anthropomorphic phantom for further conversion from air kerma to organ-absorbed dose . Radiat. Prot. Dosim. 189 , 371 – 383 ( 2020 ). Google Scholar Crossref Search ADS WorldCat 17. Japan Nuclear Energy Safety Organization (JNES) . Operational Status of Nuclear Facilities in Japan, 2013 edition. JNES, Tokyo, 13–19 ( 2013 ). 18. Oumi , T. , Shouji , H. and Imai , T. Dose reduction activities in Japanese nuclear power plants and dose forecast in future (in Japanese) . Jpn. J. Health. Phys. 46 ( 2 ), 132 – 139 ( 2011 ). Google Scholar Crossref Search ADS WorldCat 19. Central Research Institute of Electric Power Industry (CRIEPI) . Study on accuracy improvement of external exposure dose assessment (Final report in Japanese). In: Electric Power Companies’ Joint Commissioned Research (EPCJCR) . ( 1983 ). 20. Inc , C. R. S. Study on establishment of external exposure dose evaluation method (final report in Japanese) . Electric Power Companies’ Joint Commissioned Research (EPCJCR) ( 1986 ). 21. Radiation Effects Association . Report on organ dose reconstruction study meeting (in Japanese, but abstract available in English) (2019). http://www.rea.or.jp/ ( 5 July 2020, date last accessed). 22. International Commission on Radiological Protection . Recommendations of the International Commission on Radiological. Protection ICRP Publication 26 . Ann. ICRP , 1 ( 3 ), 3 – 6 , 14-26 ( 1977 ). Crossref Search ADS 23. Central Research Institute of Electric Power Industry (CRIEPI) . Application of in-situ monitoring method of effective dose equivalent ( in Japanese ). Energy and environment laboratory report 284060. CRIEPI, 6 – 13 ( 1985 ). 24. TEPCO Environmental Engineering Inc . Study on application of external exposure dose evaluation method (final report in Japanese) . TEPCO Commissioned survey ( 1984 ). 25. Ministry of Education, Culture, Sports, Science and Technology (MEXT) . NaI (Tl) scintillation spectrometer instrumental analysis (in Japanese) . Radioactivity measurement method series No. 6 ( 1974 ). 26. International Commission on Radiological Protection . Conversion coefficients for use in radiological protection against external radiation. ICRP publication 74 . Ann. ICRP 26 ( 3/4 ), 159 ( 1996 ). OpenURL Placeholder Text WorldCat Appendix. Trial estimation method of energy distribution of gamma ray from PHC of NaI detector A case of ‘below the steam generator (SG) manhole’ of PWR is shown below. (1) From the line of ‘without lead shield container cap on NaI detector’ at ‘below the SG manhole’ in Figure 2, the PHC between 0.1 and 1.6 MeV at 0.1 MeV interval was digitized as Table A1. Table A1 PHC of ‘below the SG manhole’. Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Counting rate (1000 counts/40 sec) 77 251 194 158 123 105 105 74 57 46 42 36 26 18 12 9 Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Counting rate (1000 counts/40 sec) 77 251 194 158 123 105 105 74 57 46 42 36 26 18 12 9 Open in new tab Table A1 PHC of ‘below the SG manhole’. Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Counting rate (1000 counts/40 sec) 77 251 194 158 123 105 105 74 57 46 42 36 26 18 12 9 Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Counting rate (1000 counts/40 sec) 77 251 194 158 123 105 105 74 57 46 42 36 26 18 12 9 Open in new tab Table A2 Compton scattering fraction ratio. 0.2 0.10 1.00 0.3 0.21 0.08 1.00 0.4 0.27 0.22 0.03 1.00 0.5 0.29 0.23 0.22 0.01 1.00 0.6 0.23 0.23 0.22 0.25 0.02 1.00 0.7 0.23 0.23 0.23 0.27 0.22 0.02 1.00 0.8 0.21 0.21 0.21 0.24 0.28 0.20 0.02 1.00 0.9 0.21 0.21 0.21 0.22 0.24 0.28 0.20 0.04 1.00 1.0 0.21 0.21 0.21 0.21 0.22 0.23 0.29 0.20 0.05 1.00 1.1 0.20 0.20 0.20 0.21 0.21 0.22 0.27 0.26 0.18 0.06 1.00 1.2 0.20 0.20 0.20 0.20 0.21 0.22 0.22 0.28 0.29 0.17 0.07 1.00 1.3 0.19 0.19 0.21 0.21 0.21 0.21 0.26 0.26 0.32 0.35 0.18 0.25 1.00 1.4 0.19 0.19 0.19 0.20 0.22 0.22 0.22 0.26 0.29 0.34 0.38 0.18 0.29 1.00 1.5 0.18 0.18 0.19 0.19 0.19 0.21 0.22 0.23 0.25 0.29 0.33 0.40 0.17 0.27 1.00 1.6 0.19 0.19 0.19 0.19 0.19 0.20 0.20 0.19 0.24 0.27 0.31 0.34 0.41 0.19 0.23 1.00 MeV 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 0.2 0.10 1.00 0.3 0.21 0.08 1.00 0.4 0.27 0.22 0.03 1.00 0.5 0.29 0.23 0.22 0.01 1.00 0.6 0.23 0.23 0.22 0.25 0.02 1.00 0.7 0.23 0.23 0.23 0.27 0.22 0.02 1.00 0.8 0.21 0.21 0.21 0.24 0.28 0.20 0.02 1.00 0.9 0.21 0.21 0.21 0.22 0.24 0.28 0.20 0.04 1.00 1.0 0.21 0.21 0.21 0.21 0.22 0.23 0.29 0.20 0.05 1.00 1.1 0.20 0.20 0.20 0.21 0.21 0.22 0.27 0.26 0.18 0.06 1.00 1.2 0.20 0.20 0.20 0.20 0.21 0.22 0.22 0.28 0.29 0.17 0.07 1.00 1.3 0.19 0.19 0.21 0.21 0.21 0.21 0.26 0.26 0.32 0.35 0.18 0.25 1.00 1.4 0.19 0.19 0.19 0.20 0.22 0.22 0.22 0.26 0.29 0.34 0.38 0.18 0.29 1.00 1.5 0.18 0.18 0.19 0.19 0.19 0.21 0.22 0.23 0.25 0.29 0.33 0.40 0.17 0.27 1.00 1.6 0.19 0.19 0.19 0.19 0.19 0.20 0.20 0.19 0.24 0.27 0.31 0.34 0.41 0.19 0.23 1.00 MeV 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 Open in new tab Table A2 Compton scattering fraction ratio. 0.2 0.10 1.00 0.3 0.21 0.08 1.00 0.4 0.27 0.22 0.03 1.00 0.5 0.29 0.23 0.22 0.01 1.00 0.6 0.23 0.23 0.22 0.25 0.02 1.00 0.7 0.23 0.23 0.23 0.27 0.22 0.02 1.00 0.8 0.21 0.21 0.21 0.24 0.28 0.20 0.02 1.00 0.9 0.21 0.21 0.21 0.22 0.24 0.28 0.20 0.04 1.00 1.0 0.21 0.21 0.21 0.21 0.22 0.23 0.29 0.20 0.05 1.00 1.1 0.20 0.20 0.20 0.21 0.21 0.22 0.27 0.26 0.18 0.06 1.00 1.2 0.20 0.20 0.20 0.20 0.21 0.22 0.22 0.28 0.29 0.17 0.07 1.00 1.3 0.19 0.19 0.21 0.21 0.21 0.21 0.26 0.26 0.32 0.35 0.18 0.25 1.00 1.4 0.19 0.19 0.19 0.20 0.22 0.22 0.22 0.26 0.29 0.34 0.38 0.18 0.29 1.00 1.5 0.18 0.18 0.19 0.19 0.19 0.21 0.22 0.23 0.25 0.29 0.33 0.40 0.17 0.27 1.00 1.6 0.19 0.19 0.19 0.19 0.19 0.20 0.20 0.19 0.24 0.27 0.31 0.34 0.41 0.19 0.23 1.00 MeV 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 0.2 0.10 1.00 0.3 0.21 0.08 1.00 0.4 0.27 0.22 0.03 1.00 0.5 0.29 0.23 0.22 0.01 1.00 0.6 0.23 0.23 0.22 0.25 0.02 1.00 0.7 0.23 0.23 0.23 0.27 0.22 0.02 1.00 0.8 0.21 0.21 0.21 0.24 0.28 0.20 0.02 1.00 0.9 0.21 0.21 0.21 0.22 0.24 0.28 0.20 0.04 1.00 1.0 0.21 0.21 0.21 0.21 0.22 0.23 0.29 0.20 0.05 1.00 1.1 0.20 0.20 0.20 0.21 0.21 0.22 0.27 0.26 0.18 0.06 1.00 1.2 0.20 0.20 0.20 0.20 0.21 0.22 0.22 0.28 0.29 0.17 0.07 1.00 1.3 0.19 0.19 0.21 0.21 0.21 0.21 0.26 0.26 0.32 0.35 0.18 0.25 1.00 1.4 0.19 0.19 0.19 0.20 0.22 0.22 0.22 0.26 0.29 0.34 0.38 0.18 0.29 1.00 1.5 0.18 0.18 0.19 0.19 0.19 0.21 0.22 0.23 0.25 0.29 0.33 0.40 0.17 0.27 1.00 1.6 0.19 0.19 0.19 0.19 0.19 0.20 0.20 0.19 0.24 0.27 0.31 0.34 0.41 0.19 0.23 1.00 MeV 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 Open in new tab Considering the Compton scattering fraction in the PHC, the number of incident photons by energy, called as unfolded data or corrected count data, was estimated as follows. (2) The counting rate of 9 (1000 counts/40 sec) at the energy band of 1.6 MeV, indicating a width of 1.5–1.6 MeV, was assumed to be derived from gamma ray of that energy band. (3) Compton scattering fraction at lower energy bands derived from the highest energy of 1.6 MeV was firstly removed from the PHC, as the next. Figure 2 (4) of the response matrix (0–3 MeV) for 3-inch spherical NaI in the reference of CRIEPI (1985)(23) was used for the estimation of the Compton scattering fraction. It was assumed that the response matrix was M(i, j) (i, j = 1, 2,..., 30), i represented an gamma-ray incident energy band of i/10 (MeV), j represented channel of energy band j/10 (MeV) and M(i, j) indicated the PHC at channel of energy band j/10 (MeV) in case of gamma-ray incident with energy band of i/10 (MeV). The Compton scattering fraction ratio derived from gamma-ray incident of 1.6 MeV (i = 16) was defined as M(16, j)/M(16, 16) for channel of the lower energy band j (j = 1, 2,..., 15). For each incident energy band (the i-th row), the Compton scattering fraction ratio included in the lower energy band (the j-th column) is determined as Table A2. (4) The PHC of 9 at 1.6 MeV (Table A1) was multiplied by the Compton scattering fraction ratio at the energy band j of the 1.6 MeV row (i = 16) in Table A2, followed by subtracting the multiplication value from PHC at the energy band j in Table A1. Then, with respect to 1.5 MeV energy band, next to the highest energy band, the same process described above was performed. The steps were sequentially performed until the lowest energy band, completing the corrected count data. This process, called stripping method, was illustrated as the triangular matrix (Table A3). A solution could not be obtained because the PHC of 0.1 MeV or less disappeared for the energy of 0.4 MeV or less. The reason might be that there was no information on the lower limit energy of the pulse height and that the response matrix itself was a reference value. However, since this was a simple analysis, the process was repeated until peak components could be subtracted. Table A3 Corrected count data (1000 counts/40 sec). MeV . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.3 . 1.3 . 1.4 . 1.5 . 1.6 . 1.6 77 251 194 158 123 105 105 74 57 46 42 36 26 18 12 9 1.5 75 249 192 156 121 103 103 72 55 44 39 33 22 16 10 1.4 74 248 190 154 119 101 101 70 52 41 36 29 21 14 1.3 71 245 188 152 116 98 98 66 48 36 31 27 17 1.2 68 242 184 148 113 95 94 62 43 30 28 22 1.1 63 237 180 144 108 90 89 56 36 26 26 1.0 58 232 175 138 103 84 82 49 32 25 0.9 53 227 169 133 97 78 74 44 30 0.8 47 221 163 126 90 70 68 43 0.7 37 211 154 116 78 61 67 0.6 22 196 138 98 63 59 0.5 8 182 125 83 62 0.4 0 168 111 82 0.3 0 150 109 0.2 0 142 Unfold 0 142 109 82 62 59 67 43 30 25 26 22 17 14 10 9 MeV . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.3 . 1.3 . 1.4 . 1.5 . 1.6 . 1.6 77 251 194 158 123 105 105 74 57 46 42 36 26 18 12 9 1.5 75 249 192 156 121 103 103 72 55 44 39 33 22 16 10 1.4 74 248 190 154 119 101 101 70 52 41 36 29 21 14 1.3 71 245 188 152 116 98 98 66 48 36 31 27 17 1.2 68 242 184 148 113 95 94 62 43 30 28 22 1.1 63 237 180 144 108 90 89 56 36 26 26 1.0 58 232 175 138 103 84 82 49 32 25 0.9 53 227 169 133 97 78 74 44 30 0.8 47 221 163 126 90 70 68 43 0.7 37 211 154 116 78 61 67 0.6 22 196 138 98 63 59 0.5 8 182 125 83 62 0.4 0 168 111 82 0.3 0 150 109 0.2 0 142 Unfold 0 142 109 82 62 59 67 43 30 25 26 22 17 14 10 9 Open in new tab Table A3 Corrected count data (1000 counts/40 sec). MeV . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.3 . 1.3 . 1.4 . 1.5 . 1.6 . 1.6 77 251 194 158 123 105 105 74 57 46 42 36 26 18 12 9 1.5 75 249 192 156 121 103 103 72 55 44 39 33 22 16 10 1.4 74 248 190 154 119 101 101 70 52 41 36 29 21 14 1.3 71 245 188 152 116 98 98 66 48 36 31 27 17 1.2 68 242 184 148 113 95 94 62 43 30 28 22 1.1 63 237 180 144 108 90 89 56 36 26 26 1.0 58 232 175 138 103 84 82 49 32 25 0.9 53 227 169 133 97 78 74 44 30 0.8 47 221 163 126 90 70 68 43 0.7 37 211 154 116 78 61 67 0.6 22 196 138 98 63 59 0.5 8 182 125 83 62 0.4 0 168 111 82 0.3 0 150 109 0.2 0 142 Unfold 0 142 109 82 62 59 67 43 30 25 26 22 17 14 10 9 MeV . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.3 . 1.3 . 1.4 . 1.5 . 1.6 . 1.6 77 251 194 158 123 105 105 74 57 46 42 36 26 18 12 9 1.5 75 249 192 156 121 103 103 72 55 44 39 33 22 16 10 1.4 74 248 190 154 119 101 101 70 52 41 36 29 21 14 1.3 71 245 188 152 116 98 98 66 48 36 31 27 17 1.2 68 242 184 148 113 95 94 62 43 30 28 22 1.1 63 237 180 144 108 90 89 56 36 26 26 1.0 58 232 175 138 103 84 82 49 32 25 0.9 53 227 169 133 97 78 74 44 30 0.8 47 221 163 126 90 70 68 43 0.7 37 211 154 116 78 61 67 0.6 22 196 138 98 63 59 0.5 8 182 125 83 62 0.4 0 168 111 82 0.3 0 150 109 0.2 0 142 Unfold 0 142 109 82 62 59 67 43 30 25 26 22 17 14 10 9 Open in new tab Table A4 Gamma-ray flux by energy band. Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Gamma-ray flux (unit: 10−3 γ/cm2/sec) 0 54 53 49 47 52 69 50 39 35 38 35 28 25 19 19 Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Gamma-ray flux (unit: 10−3 γ/cm2/sec) 0 54 53 49 47 52 69 50 39 35 38 35 28 25 19 19 Open in new tab Table A4 Gamma-ray flux by energy band. Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Gamma-ray flux (unit: 10−3 γ/cm2/sec) 0 54 53 49 47 52 69 50 39 35 38 35 28 25 19 19 Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Gamma-ray flux (unit: 10−3 γ/cm2/sec) 0 54 53 49 47 52 69 50 39 35 38 35 28 25 19 19 Open in new tab Table A5 Air kerma rate by energy band. Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Air kerma rate (unit: 10−15 Gy/h) 0 50 74 91 110 144 218 180 156 154 182 181 154 144 118 123 Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Air kerma rate (unit: 10−15 Gy/h) 0 50 74 91 110 144 218 180 156 154 182 181 154 144 118 123 Open in new tab Table A5 Air kerma rate by energy band. Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Air kerma rate (unit: 10−15 Gy/h) 0 50 74 91 110 144 218 180 156 154 182 181 154 144 118 123 Energy band (MeV) . 0.1 . 0.2 . 0.3 . 0.4 . 0.5 . 0.6 . 0.7 . 0.8 . 0.9 . 1.0 . 1.1 . 1.2 . 1.3 . 1.4 . 1.5 . 1.6 . Air kerma rate (unit: 10−15 Gy/h) 0 50 74 91 110 144 218 180 156 154 182 181 154 144 118 123 Open in new tab The first row at 1.6 MeV in Table A3 came from Table A1. When the incident of gamma ray at 1.6 MeV was ‘9’, the value at 1.5 MeV row was obtained by subtracting the Compton scattering fraction generated thereby from PHC of the first row at the energy band <1.5 MeV (j = 1, 2,..., 15). Next, when ‘10’ of the 1.5 MeV band in column of the 1.5 MeV row was incident, the Compton scattering fraction generated thereby was subtracted from the corrected PHC at energy band of 1.4 MeV or less. This was repeated until the 0.2 MeV row. The lowermost row of ‘unfold’ was obtained by taking out diagonal components of a triangular matrix and was the corrected count data in which Compton scattering fraction had been removed (unit: 1000 counts/40 sec). (5) The corrected count data were converted into gamma-ray flux by energy band in consideration of detection sensitivity of NaI detector, as shown in Table A4. For detection sensitivity, the Figure 7.3 of ‘gamma counting efficiency (%) of NaI (Tl) scintillation detector’ in MEXT (1974)(25) was referred. (6) The gamma ray flux by energy band was converted to air kerma rate (unit: 10−15 Gy/h), as shown in Table A5. The fluence–kerma conversion factor (unit: 10−12 Gy cm2) was applied by interpolating Table A.1 of ICRP Publ. 74(26) with quadratic formula. Based on this air kerma rate, the dose ratio of <0.3 MeV was estimated as the next. Less than 0.3 MeV:0.3 MeV and over = 124: 1954 = 6%: 94%. © The Author(s) 2020. Published by Oxford University Press. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. © The Author(s) 2020. Published by Oxford University Press. TI - ESTIMATION OF PHOTON ENERGY AND DIRECTION DISTRIBUTIONS AT JAPANESE NUCLEAR POWER PLANTS BASED ON LITERATURE SURVEY FOR J-EPISODE STUDY JF - Radiation Protection Dosimetry DO - 10.1093/rpd/ncaa111 DA - 2020-10-16 UR - https://www.deepdyve.com/lp/oxford-university-press/estimation-of-photon-energy-and-direction-distributions-at-japanese-luRjP0zmR9 SP - 372 EP - 391 VL - 190 IS - 4 DP - DeepDyve ER -