TY - JOUR AU - Chuck, Roy S. AB - ObjectiveTo compare postoperative astigmatic change and graft stability using 2 different donor button diameters in endothelial lamellar keratoplasty to treat corneal endothelial failure.MethodsA 200-µm-thick corneal flap keratectomy was performed in human donor corneoscleral rims (n = 20; 10 donors and 10 recipients) using an artificial anterior chamber and a manual microkeratome (ALTK System; Moria USA, Doylestown, Pa). After flap reflection, stromal bed trephination was performed to obtain a disc consisting of posterior stroma, Descemet membrane, and endothelium. Host beds of 7.0 mm and 7.25-mm (n = 5) or 7.50-mm (n = 5) donor buttons were obtained using a freehand trephine. The graft was secured with 8 interrupted sutures (10-0 nylon) in the stromal bed. The flap was sutured with 3 interrupted sutures. Transplanted corneas were submitted to increasing intrachamber pressures to detect graft stability, and preoperative and postoperative videokeratographic data were recorded to assess astigmatic change.ResultsThe mean (SD) postoperative astigmatic change was 1.14 (3.17) diopters (D) in the 7.25-mm donor button group and 2.27 (1.77) D in the 7.50-mm donor button group (P= .69). Mean (SD) resisted pressures of 75.4 (44.81) mm Hg and 100.4 (46.86) mm Hg were observed in the 7.25-mm and 7.50-mm groups, respectively (P= .54).ConclusionBoth donor button sizes exhibited similar graft stability and astigmatic postoperative change in this experimental model.Clinical RelevanceAs endothelial lamellar keratoplasty becomes further developed as a clinical alternative to penetrating keratoplasty, this laboratory model system should be useful in evaluating different mechanical factors that contribute to graft success.PENETRATING KERATOPLASTY is a safe and effective method for restoring corneal transparency in patients with disabling corneal opacities.Endothelial cell dysfunction accounts for most penetrating keratoplasties performed in developed countries.Endothelial cell failure has been frequently associated with either ocular trauma after intraocular lens implantation or endothelial corneal dystrophies.Other entities associated with corneal endothelial damage, such as pseudoexfoliation keratopathy, may affect these statistics in the future.Endothelial cell transplantation has been attempted.With the development of new biomaterials, this method might be ideal to correct endothelial cell failure.However, present clinical applications appear to be feasible only using a posterior stromal lamellar carrier (posterior lamellar keratoplasty). In this approach, replacement of the posterior stroma, Descemet membrane, and endothelial cell layer is accomplished through a scleral pocket.The technique has shown promising results. However, it is laborious and requires a highly skilled surgeon.Laser-assisted in situ keratomileusis (LASIK) has recently led to further developments in corneal lamellar surgery; LASIK instruments can be used to perform posterior lamellar transplantation using a corneal flap technique with trephination of the stromal bed, including Descemet membrane and the damaged endothelium. Several recent studies have shown promising results using these techniques in human subjects.Advantages include preservation of the original central corneal surface, avoidance of extensive superficial suturing, and a decrease in the amount of tissue transplanted. Thus, the potential exists for improvement in postoperative visual recovery, fewer problems related to sutures, and a lower rejection rate with endothelial lamellar keratoplasty.The purpose of this study was to evaluate graft stability and postoperative astigmatic change with endothelial lamellar keratoplasty using 2 different donor button sizes.METHODSDONOR TISSUEAfter approval by the Institutional Review Board of the University of California, Irvine, donor corneoscleral rims (n = 20) not suitable for transplantation were obtained from the Doheny Eye and Tissue Bank (Los Angeles, Calif). The corneas were preserved under standard eye bank conditions in Optisol-GS medium (Bausch & Lomb Surgical, Inc, San Dimas, Calif) at 4°C until the operation. The procedure was performed no longer than 15 days after death. Upon availability, corneas were sequentially assigned to 1 of 2 groups, the donor group (n = 10) or the host group (n = 10). Demographic data are shown in Table 1.Table 1. Data Collected From Donor and Host CorneasAge, y/SexTrephination Size, mmCentral Corneal Thickness, µmDonorHostDonorHostDonorHost63/M67/M7.257.066077221/F68/M7.257.090278268/M68/M7.257.0>100082668/F36/M7.257.089388058/M70/M7.257.095286072/M68/M7.507.073092068/M59/F7.507.0>100089447/M72/M7.507.090558558/M38/M7.507.095662574/M70/M7.507.0816802EXPERIMENTAL SETTINGA manual microkeratome (LSK One; Moria USA, Doylestown, Pa) was used to perform the hinged-flap keratectomy. New stainless steel blades were repeatedly used no more than 4 times to avoid cutting edge deterioration and cut surface irregularity.A 200-µm head thickness was used in all corneas. An artificial anterior chamber (ALTK System; Moria USA) was used to support the corneoscleral rims, as described in previous reports.The gearless tracks on the base plate of the artificial anterior chamber are designed to fit into the microkeratome head, so that its pass across the cornea maintains the same plane and direction. All corneal buttons were obtained using a freehand trephine. Hosts' stromal beds were cut with a 7.0-mm trephine, whereas donor stromal buttons were oversized by either 0.25 mm (n = 5) or 0.5 mm (n = 5). As they became available, transplanted corneas were alternately placed into 2 study groups, the 7.25-mm donor button group or the 7.5-mm donor button group, for comparative purposes.TECHNIQUETo reduce the number of air bubbles inside the chamber, infusion of isotonic sodium chloride was released before the corneoscleral rims were placed on the base of the anterior chamber to clear the residual air from the infusion line and underneath the cornea. The isotonic sodium chloride solution bottle was raised 1.5 m above the level of the chamber to obtain adequate intrachamber pressures (110 mm Hg) for the microkeratome pass. Corneas were centered according to circular guides in the base of the chamber. Mechanical epithelial scraping was performed with a Bard-Parker No. 11 surgical blade (Becton, Dickinson and Co, Hancock, NY) to avoid surface irregularities due to loose epithelium, which may introduce errors in pachymetric and videokeratographic measurements.Intended Flap DiameterApplanation lenses were placed on the cornea to determine the diameter to be obtained, as described elsewhere.The artificial anterior chamber was set to achieve a 10-mm-diameter flap in all cases. The largest flap diameter was intended to leave as much area in the stromal bed as possible for performing trephination and donor button suturing in the host.KeratectomySeveral drops of 0.5% proparacaine hydrochloride were applied to the corneal surface prior to the microkeratome pass to resemble clinical conditions. Keratectomy was performed by passing the microkeratome head with its oscillating blade at a relatively constant speed across the plate. The same experienced surgeon (A.B.) performed all keratectomies using the right hand for a right-to-left microkeratome pass.Flap Thickness MeasurementsAfter epithelium removal, the isotonic sodium chloride infusion was closed, and corneal thickness was measured using an ultrasound pachymeter (Ophthasonic A Scan/Pachymeter; Mentor O & O, Inc, Norwell, Mass) in the center of the cornea. A second measurement was made after the hinged flap was created and reflected from the stromal bed. Central flap thickness was calculated.Stromal Bed TrephinationIntrachamber pressure was returned to 18 to 20 mm Hg by lowering the height of the isotonic sodium chloride solution bottle to 25 cm above the cornea level, and the trephine was centered according to the keratectomy edge. A freehand trephine of 7.0 mm for the host cornea and either 7.25 mm or 7.5 mm for the donor buttons was used to perform a circular cut of the stromal bed. This was manually centered in the recipient bed relative to the flap. The trephine blade was rotated until perforation, and the circular cut was completed with corneal scissors (Figure 1). Donor buttons were sutured in recipient beds with 8 interrupted sutures, the knots were buried, and the flap was replaced in the bed (Figure 2). The suturing technique (suture tightness and length) was the same in both groups to ensure comparable results. Eight sutures were successfully placed in all cases. However, because of the size of the flap and button, shorter than normal suture passes were required. The flap was secured with 3 interrupted sutures (Figure 3).Figure 1.After flap reflection (black arrows), trephination with a freehand trephine is centered on the stromal bed surface (white arrows), avoiding the cut of the flap hinge. The host stromal bed (white arrowheads) is ready to receive a similar disc from a donor. Asterisk indicates the artificial anterior chamber.Figure 2.The donor button is sutured in the recipient bed with 8 interrupted sutures in the host stromal bed. The flap hinge must be free of sutures (arrows). Asterisk indicates the artificial anterior chamber.Figure 3.Once the donor button is in place, the flap is repositioned and sutured with 3 interrupted sutures (arrows) to avoid flap dislodgment. Asterisk indicates the artificial anterior chamber.VIDEOKERATOGRAPHY AND GRAFT STABILITYFor surface curvature analysis, we used a commercial videokeratoscope (EyeSys Laboratories, Inc, Houston, Tex). The Placido disc was placed in a vertical position and the chamber centered according to the monitor control. This setting to obtain reproducible measurements was adopted from a previous study.The orientation was preserved in preoperative and postoperative recordings. Three measurements were performed preoperatively and postoperatively for each recipient cornea (Figure 4).Figure 4.Example of preoperative and postoperative corneal topography. NAS indicates nasal; TMP, temporal.To assess graft stability, intrachamber pressure was raised progressively by changing stepwise the height of the bottle, as previously reported.Under visual control with a surgical microscope at ×12 magnification (Ophthalmic 900S; Moeller-Wedel, Hamburg, Germany), presence of leakage was monitored, and the height at which leakage occurred was recorded. Intrachamber pressure was then calculated in millimeters of mercury, according to previous measurements performed using a Tonopen XL (Medtronic Xomed, Inc, Jacksonville, Fla).STATISTICAL ANALYSISCalculations were made using StatsDirect, version 1.9.0, biostatistical software (CamCode, Ashwell, England). Mean, SD, and minimum and maximum values were described. Comparisons between groups were performed using the nonparametric Mann-Whitney Utest for unpaired samples and the Wilcoxon signed rank test for paired samples. A Spearman rank correlation test was performed to assess the dependence of resisted pressure on donor size. P≤.05 was considered statistically significant.RESULTSSURGICAL TECHNIQUEThe surgical procedure was simple and similar to a combination of a corneal flap technique and penetrating keratoplasty. Full-depth trephination of the stromal bed was performed in a similar fashion for both recipient and donor corneas. Some difficulties in suturing were encountered, because less space for suture placement was left under the flap. Likewise, a full-thickness perforating needle pass was more likely to occur because the donor button is considerably thinner than a normal cornea.The technique is somewhat more laborious than a standard penetrating keratoplasty because of the microkeratome involvement. However, the suturing time is considerably shorter, which decreases the total surgical time.SURGICAL OUTCOMEThe mean (SD) flap thickness was 191.1 (70.55) µm in donors and 240.4 (102.82) µm in hosts.The mean (SD) preoperative astigmatism in hosts was 1.41 (1.39) diopters (D), compared with 3.32 (1.51) D postoperatively. The mean (SD) postoperative astigmatic change was 1.70 (2.49) D. Keratometric data are shown in Table 2.Table 2. Keratometric Analysis of Host Corneoscleral Rims in the Artificial Anterior ChamberGraft Oversize, mmPreoperative Astigmatism, DPostoperative Astigmatism, DK1K2K1K20.2543.0742.1350.1444.680.2545.8841.5249.7447.220.2544.4741.0540.1336.390.2542.3942.2846.9442.400.2549.6846.7132.7131.520.5043.5142.6944.7540.140.5045.5544.6537.4535.790.5042.9942.4742.3437.430.5043.7343.4037.0034.730.5049.1247.3352.5150.25Abbreviations: D, diopters; K, corneal curvature keratometric value.Comparing the 2 donor sizes, we found no statistically significant differences in postoperative astigmatic change. The mean (SD) postoperative astigmatic change was 1.14 (3.17) D for the 7.25-mm donor button group and 2.27 (1.76) D for the 7.5-mm donor button group. Despite a lower mean astigmatic change using the smaller donor button, this difference was not significant (P= .69).There were very large variations in the preoperative and postoperative change in average keratometry values in both groups. The mean (SD) change in average keratometry value for the 7.25-mm donor button group was 1.45 (7.36) D; for the 7.5-mm group, the mean (SD) change was 2.76 (4.00) D.In terms of stability of the graft, we observed great variability in both groups. A higher resistance with larger donor buttons was observed. The mean (SD) calculated pressure was 100.4 (46.86) mm Hg (range, 48-143 mm Hg) in the 7.5-mm donor button group, opposed to 75.4 (44.81) mm Hg (range, 37-147 mm Hg) in the 7.25-mm donor button group. However, this difference was not statistically significant (P= .63), and no correlation between size and intrachamber resisted pressure was found (rs= 0.243; P= .49).COMMENTNew surgical techniques are being developed in parallel with advances in ophthalmic technology. Lamellar corneal surgery has become more popular recently because of the improvement in microkeratome instrumentation. Safety while using these instruments has improved considerably, and a remarkable cut quality has been achieved with the latest systems.In lamellar transplants, the smoothness of the cut surface may lead to a better surgical outcome with a clearer interface, which is essential to obtaining a good optical result.This has led to the proposal of endothelial lamellar keratoplasty as an alternative to penetrating keratoplasty in patients with endothelial cell dysfunction. Busin et aldescribed the procedure in 7 patients; they secured the donor button in its recipient bed with an 8-bite running suture and the flap with an additional 8-bite running suture. In 4 cases, they used a full-thickness corneal donor button oversized by 0.5 mm, and in 3 cases, they used a partial-thickness button obtained by means of an artificial anterior chamber, a rotating blade microkeratome, and a trephine. All donor discs were obtained through a trephination from the endothelial side. In all cases, the corneal flap in the recipient was obtained with an oscillating blade microkeratome.In our study, the same instruments for flap creation and trephination were used for both recipient and donor corneas. We believe that it is important to preserve the same conditions of the cut in both recipient and donor during corneal flap creation and trephination. Surface cuts have displayed considerable variation using different microkeratomes.We found a large variation in flap thickness even using the same microkeratome. This could be due to variations in stromal hydration before the microkeratome cut is created. Raising the pressure in the artificial anterior chamber to adequate levels to create the flap might induce significant amounts of stromal hydration. Even donor button orientation might be important to avoid cut surface mismatches in the interface. Moreover, donor button thickness may vary significantly in different sectors according to the quadrant location, which might introduce additional irregularities in overall corneal thickness. In our study, the buttons were excised with full-depth trephination and scissors. This could result in slightly ragged edges, which may compromise wound stability.The resultant astigmatism after penetrating keratoplasty is variable. With standard trephination methods, the mean astigmatism fluctuates between 3 and 6 D.With excimer laser trephination, the mean keratometric astigmatism fluctuates between 3 and 3.5 D.In endokeratoplasty, the mean refractive astigmatism in the small series reported was 2.9 D,whereas in our series it was 3.3 D. Astigmatic change (preoperative astigmatism minus postoperative astigmatism), a more reliable method of comparison between techniques, is not usually presented in the literature. In addition, the terms "refractive," "keratometric," and "topographic astigmatism" are mistakenly used interchangeably, adding another source of error for comparative purposes.In myopic LASIK, a flap is replaced on a stromal bed that has been flattened, and this flattening is transmitted to the surface by the flap. In endothelial lamellar keratoplasty, an irregular stromal bed is created by the sutured button. This irregularity is also transmitted to the surface by the flap, as we have shown in the shifts in average corneal power and astigmatism. In a human subject case report of this procedure, a large change in corneal power was observed in the early postoperative period.Thus, the challenge in this form of endothelial lamellar keratoplasty is to create as regular a stromal bed surface as possible before laying down the conforming anterior corneal flap. If interrupted sutures are insufficient, other possibilities include running sutures, glues, and sutureless buttons.Our initial goal was to place the sutures only in the graft bed, with a sutureless hinged flap, as is performed in LASIK. However, the endothelial pump function is severely altered in a donor button, which may compromise flap adherence and, therefore, promote flap slippage after the procedure. Because of this, we sutured the flap with 3 interrupted sutures in the 3 free quadrants (excluding the hinge) to add more stability. These sutures may be removed in the early postoperative period once the endothelial pump function is recovered and the epithelium has healed.We found no statistical differences in bursting pressure using different donor sizes. On average, the bursting pressure was above physiologic levels and presumably would result in a watertight procedure. However, there was a wide range in bursting pressure, and the lowest (37 mm Hg) could potentially result in a leaking graft clinically. Thus, further refinements of the procedure, possibly more sutures in the flap, are required to obtain consistent results.Limitations of this study include the effect of confounding variables other than donor size on induced astigmatism and bursting pressure. In particular, variations in the tightness of the flap sutures can have a profound effect on induced astigmatism. Because it is expected that these sutures would be removed early in the postoperative course, the true effect of the differences in astigmatism due to donor size may not be apparent. The tightness of these sutures was carefully controlled to minimize the effect of this variable. Also, the high variability in measured flap thickness may result in a mismatch of donor graft to button removed.In conclusion, donor grafts oversized by either 0.25 mm or 0.50 mm exhibited similar graft stability and astigmatic changes. The wide variations in average keratometry resulted in significant differences in corneal power postoperatively. This could yield large refractive shifts in the clinical setting and minimize the benefit of reduced astigmatism in this procedure. Endothelial lamellar keratoplasty appears to be a feasible procedure that has several potential advantages over penetrating keratoplasty for endothelial cell layer dysfunction. Further testing is required to optimize this procedure before extensive use in the clinical setting.Avon HippelÜber die operative Behandlung totaler stationärer Hornhauttrübungen.Albrecht von Graefes Arch Klin Exp Ophthalmol.1877;23:79-100.Avon HippelEine neue Methode der Hornhaut Transplantation.Albrecht von Graefes Arch Klin Exp Ophthalmol.1885;34:108-130.JIBarraquerQueratomileusis para la corrección de la miopía.Arch Soc Am Oftalmol Optom.1964;5:27-48.JIBarraquerLamellar keratoplasty (special techniques).Ann Ophthalmol.1972;4:437-469.RHaimoviciWWCulbertsonOptical lamellar keratoplasty using the Barraquer microkeratome.Refract Corneal Surg.1991;7:42-45.PAiken-O'NeillMJMannisSummary of corneal transplant activity: Eye Bank Association of America.Cornea.2002;21:1-3.BSeitzEEMullerALangenbucherMMKusGOHNaumannEndothelial keratopathy in pseudoexfoliation syndrome: quantitative and qualitative morphometry using automated video image analysis [in German].Klin Monatsbl Augenheilkd.1995;207:167-175.GOHNeumannUSchlotzer-SchrehardtKeratopathy in pseudoexfoliation syndrome as a cause of corneal endothelial decompensation: a clinicopathologic study.Ophthalmology.2000;107:1111-1124.DGospodarowiczGGreenburgJAlvaradoTransplantation of cultured bovine corneal endothelial cells to rabbit cornea: clinical implications for human studies.Proc Natl Acad Sci U S A.1979;76:464-468.JMohayTMLangeJBSoltauTOWoodBJMcLaughlinTransplantation of corneal endothelial cells using a cell carrier device.Cornea.1994;13:173-182.JPMcCulleyDMMauriceBDSchwartzCorneal endothelial transplantation.Ophthalmology.1980;87:194-201.MMJumblattDMMauriceJPMcCulleyTransplantation of tissue-cultured corneal endothelium.Invest Ophthalmol Vis Sci.1978;17:1135-1141.BAboalchamatKEngelmannMBohnkePEggliJBednarzMorphological and functional analysis of immortalized human corneal endothelial cells after transplantation.Exp Eye Res.1999;69:547-553.PJMcDonnellEmergence of refractive surgery.Arch Ophthalmol.2000;118:1119-1120.GRMellesFAEgginkFLanderA surgical technique for posterior lamellar keratoplasty.Cornea.1998;17:618-626.GRMellesFLanderWHBeekhuisLRemeijerPSBinderPosterior lamellar keratoplasty for a case of pseudophakic bullous keratopathy.Am J Ophthalmol.1999;127:340-341.GRMellesFLanderBTvan DoorenEPelsWHBeekhuisPreliminary clinical results of posterior lamellar keratoplasty through a sclerocorneal pocket incision.Ophthalmology.2000;107:1850-1856.MATerryThe evolution of lamellar grafting techniques over 25 years.Cornea.2000;19:611-616.MATerryPJOusleyEndothelial replacement without surface corneal incisions or sutures: topography of the deep lamellar endothelial keratoplasty procedure.Cornea.2001;20:14-18.IGPallikarisMEPapatzanakiDSSiganosMKTsilimbarisIPallikarisA corneal flap technique for laser in situ keratomileusis: human studies.Arch Ophthalmol.1991;109:1699-1702.DTAzarSJainRSamburskyLStraussMicrokeratome-assisted posterior keratoplasty.J Cataract Refract Surg.2001;27:353-356.MBusinRCArffaASebastianiEndokeratoplasty as an alternative to penetrating keratoplasty for the surgical treatment of diseased endothelium: initial results.Ophthalmology.2000;107:2077-2082.NEhlersHEhlersJHjortdalTMoller-PedersenGrafting of the posterior cornea: description of a new technique with 12-month clinical results.Acta Ophthalmol (Scand).2000;78:543-546.ABehrensAMTDoloricoDTKiraPrecision and accuracy of an artificial anterior chamber system in obtaining corneal lenticules for lamellar keratoplasty.J Cataract Refract Surg.2001;27:1679-1687.LLiKREllisABehrensLaboratory model for microkeratome-assisted posterior lamellar keratoplasty utilizing a running graft suture and a sutureless hinged flap.Cornea.2002;21:192-195.RLim-Bon-SiongJMWilliamsSSamapunphongRSChuckJSPeposeScreening of myopic photorefractive keratectomy in eye bank eyes by computerized videokeratography.Arch Ophthalmol.1998;116:617-623.BSeitzABehrensALangenbucherMMKusGOHNaumannExperimental 193 nm excimer laser corneal trephination with divergent cut angles for penetrating keratoplasty.Cornea.1998;17:410-416.ABehrensALangenbucherMMKusCRummeltBSeitzExperimental evaluation of two current-generation automated microkeratomes: the Hansatome and the Supratome.Am J Ophthalmol.2000;129:59-67.ABehrensBSeitzALangenbucherEvaluation of corneal flap dimensions and cut quality using a manually guided microkeratome.J Refract Surg.1999;15:118-123.EMPerlmanAn analysis and interpretation of refractive errors after penetrating keratoplasty.Ophthalmology.1981;88:39-45.RHGrossEJPoulsenSDavittComparison of astigmatism after penetrating keratoplasty by experienced cornea surgeons and cornea fellows.Am J Ophthalmol.1997;123:636-643.SCBelmontJLZimmRLStorchAstigmatism after penetrating keratoplasty using the Krumeich guided trephine system.Refract Corneal Surg.1993;9:250-254.BSeitzALangenbucherMMKusMKuchleGONaumannNonmechanical corneal trephination with the excimer laser improves outcome after penetrating keratoplasty.Ophthalmology.1999;106:1156-1164.Corresponding author and reprints: Roy S. Chuck, MD, PhD, Department of Ophthalmology, University of California, Irvine, 118 Med Surge I, Irvine, CA 92697 (e-mail: rschuck@uci.edu).Submitted for publication June 29, 2001; final revision received June 25, 2002; accepted December 20, 2002.This study was supported by grants from the Pan-American Association of Ophthalmology, Arlington, Tex (Dr Behrens), and the LASIK Institute, Fairfax, Va (Drs Ellis and Chuck), and grant KO8 EY00412-02 from the National Institutes of Health, Bethesda, Md (Dr Chuck).We thank Bausch & Lomb Surgical, Inc, for providing the Optisol-GS. TI - Endothelial Lamellar Keratoplasty Using an Artificial Anterior Chamber and a Microkeratome JF - JAMA Ophthalmology DO - 10.1001/archopht.121.4.503 DA - 2003-04-01 UR - https://www.deepdyve.com/lp/american-medical-association/endothelial-lamellar-keratoplasty-using-an-artificial-anterior-chamber-coD1TA1Q5r SP - 503 EP - 508 VL - 121 IS - 4 DP - DeepDyve ER -