TY - JOUR AU - Taylor, Deborah R. AB - Abstract Background. Hepatitis B virus (HBV) is an important blood-borne pathogen that causes hepatic inflammation and can lead to liver cirrhosis and hepatocellular carcinoma. Conventional methods of HBV detection are time consuming and require highly trained personnel and elaborate equipment. This report describes the development of a rapid, simple, specific, and sensitive loop-mediated isothermal amplification assay (LAMP) for detection of HBV genotypes A, B, C, D, E, and F in blood samples. Methods. HBV standard plasma panels and clinical donor plasma specimens were used for the development and validation of the LAMP assay. Amplification was performed at 60°C for 60 minutes using extracted DNA or heat-treated plasma specimens without DNA extraction. The assay was evaluated for its ability to detect various HBV genotypes and for its sensitivity, specificity, and time-point of detection. Results. The LAMP assay detected HBV genotypes A–F and demonstrated a sensitivity of 10–100 IU per reaction of HBV DNA. The assay also detected 69 of 75 (92%) HBV-positive donor plasma specimens tested and demonstrated a specificity of 100%. Conclusions. These results demonstrate that our HBV-LAMP assay is rapid, sensitive and specific, and capable of detecting the major HBV genotypes. This assay could be used in clinical point-of-care settings, mainly in endemic and resource-limited environments for HBV diagnostics, donor screening, epidemiological studies, and therapeutic monitoring of patients undergoing antiviral treatment. hepatitis B virus, loop-mediated isothermal amplification, nucleotide, rapid detection, international units per reaction Hepatitis B virus (HBV) is a blood-borne pathogen that infects >4 million people yearly. Approximately 350 million people worldwide are chronically infected and are infectious carriers of the virus. Mainly transmitted through blood-borne methods, HBV infection can lead to hepatitis, liver cirrhosis, and hepatocellular carcinoma, and often coinfects with hepatitis C virus and human immunodeficiency virus [1–3]. HBV is a circular, partially double-stranded DNA virus of 3.2 kb. There are 8 known genotypes (A–H) that are divergent by >8% across the entire genome and are distributed worldwide [4–6]. Describing the epidemiology of HBV does add to the literature, but the idea of treatment remains far-fetched in the developing world due to the high cost of antiviral drugs. However, a tool capable of generally detecting the major HBV genotypes may help in understanding the global geographic prevalence of HBV, aid in addressing the burden that HBV infection places on healthcare systems, and guide public health and clinicians in designing preventive and therapeutic measures. HBV infection is a global public health problem, particularly in poorer countries where healthcare resources are limited and inaccessible. According to the World Health Organization (WHO), countries in regions of Asia, Africa, and South/Central America have high HBV carrier rates of >8% [7, 8]. This problem is compounded by the lack of advanced medical and diagnostic laboratory services for donor screening or routine testing of patients. In many developed countries, blood donors are screened for HBV surface antigen, antibodies to the core of HBV, and HBV DNA in order to ensure safe blood supply and clinical diagnosis. Such test is conventionally performed with tests including enzyme-linked immunosorbent assay (ELISA) and real-time polymerase chain reaction (PCR). These tests are time consuming, expensive, and require skilled personnel and elaborate equipment to perform [9–11]. Hence, there is a need for a rapid and cost-effective detection tool for screening blood donors and testing patient specimens for HBV infection in endemic as well as resource-limited environments. This study reports the development of a simple, sensitive, and specific loop-mediated isothermal amplification assay (HBV-LAMP) for rapid and universal detection of all the major HBV genotypes in peripheral blood. LAMP is a DNA amplification method that uses 2–3 pairs of sequence-specific primers and a DNA strand-displacement process for amplification under isothermal condition. The amplification results in multiple inverted repeats of amplicons that form a ladder-like banding pattern [11–19]. This unique and portable detection tool has the potential for use in point-of-care settings for blood screening and patient follow-up. MATERIALS AND METHODS Specimens, Standards, and DNA Preparation HBV genotyping reference plasma panels containing various titers of WHO international standards (OptiQuant, AcroMetrix/Life Technologies, Grand Island, New York) and the Worldwide HBV DNA Performance Panel (WWHD301, SeraCare, Milford, Massachusetts) were used. A total of 182 donor plasma specimens were also used for assay development and evaluation. DNA extraction was performed using the QiAamp DNA Blood Mini Kit (Qiagen, Gaithersburg, Maryland) according to the manufacturer's protocol. DNA was extracted from 200–400 µL of plasma standards and eluted in 50–150 µL of Qiagen Buffer AE. Nucleic acid from the clinical specimens was concentrated by the addition of 0.5 M ammonium-acetate and 0.05 mg/mL glycerol (Ambion/Life Technologies), precipitated with 1 volume of 100% isopropanol (Sigma-Aldrich, St Louis, Missouri), and centrifuged, and the DNA pellet was resuspended in 25–35 µL of Buffer AE. Finally, the DNA was measured using NanoDrop-1000 (Thermo Scientific), aliquoted, and stored at −80°C until needed for testing. Heat Treatment of Donor Plasma Specimens as Substrate Substrate for HBV-LAMP was also prepared by heat treatment of donor plasma without DNA extraction. In brief, 25 µL of specimens was diluted 2-fold with nuclease-free water. The mixture was briefly vortexed and heated at 95°C for 5 minutes, then at 100°C for approximately 5 minutes. The mixture was then centrifuged at 12 000g for 3 minutes. The supernatant was reserved and 3–10 µL used in isothermal amplification for detection of HBV. Design of Oligonucleotides Sequences of HBV genotypes (n = 197) were retrieved from the GenBank database of the National Center for Biotechnology Information and from the European Nucleotide Archive of the European Molecular Biology Laboratory. The sequences were analyzed using ClustalW2. HBV genotype A (GenBank accession number AB116094) was used for primer development and targeted conserved sequences within the S gene and the partially overlapping polymerase regions of the HBV genome (Figure 1). Primers were manually designed, aided by PrimerExplorer4 and Primer3 web interfaces, and synthesized by Integrated DNA Technologies (Coralville, Iowa) and EuroFins MWG Operon (Huntsville, Alabama). The primers are stable for at least 3 years at −20 and −80°C. Figure 1. Open in new tabDownload slide Oligonucleotide sequences. Sequence of primers used in this study, their position on the hepatitis B virus genetic sequence, and their length. Abbreviations: FIP, Forward Inner Primer; HBU, Hepatitis B Universal; LF, Loop Forward; LR, Loop Reverse; RIP, Reverse Inner Primer. Figure 1. Open in new tabDownload slide Oligonucleotide sequences. Sequence of primers used in this study, their position on the hepatitis B virus genetic sequence, and their length. Abbreviations: FIP, Forward Inner Primer; HBU, Hepatitis B Universal; LF, Loop Forward; LR, Loop Reverse; RIP, Reverse Inner Primer. HBV-LAMP Assay Design Formulation of Reaction Buffer A novel thermostable reaction buffer, the mannitol-acetate buffer (MAB; pH 7.8) was formulated and used for the LAMP reaction. MAB consisted of 2% d-mannitol; 0.2% Triton X-100; 0.5M l-proline; 10 mM Tris acetate; 1.6 mM magnesium acetate; 15 mM potassium acetate; 40 mM Tris hydrochloride; 20 mM potassium chloride; 20 mM ammonium sulfate; 6 mM magnesium sulfate; and 2 mM each deoxynucleotide triphosphate. Accelerated Stability Studies of Reaction Buffer Aliquots of the MAB were stored at room temperature (22°C–25°C) under sterile condition for approximately 6 months and then evaluated in LAMP for its stability when used to amplify nucleic acid. In addition, accelerated stability studies were performed by heating freshly formulated MAB at 60°C for 60 minutes, cooled at room temperature, heated again for an additional 30 minutes (3 times daily for 5 days), then used in LAMP reactions for detection of HBV DNA. Reaction Mixture and Condition Isothermal amplification of the HBV DNA was performed in a 25-µL total reaction mixture. Reaction cocktail consisted of 12.5 µL of 2× MAB; 1.2 µM each of Hepatitis-B-Universal Forward Inner Primer (HBU-FIP) and HBU-Reverse Inner Primer (RIP); 0.8 µM each of HBU-Loop Forward (LF) and HBU-Loop Reverse Primer (LR); 0.4 µM each of HBU-Forward Outer Primer (F3) and HBU-Reverse Outer Primer (R3); and 8 units of Bst DNA polymerase (New England Biolabs). Three to 10 µL of DNA or heat-treated plasma was applied as template. A no-template (water) control and DNA extracted from HBV-negative plasma were used as negative controls. DNA of known HBV genotypes was used as positive control. Isothermal amplification was performed at 60°C for 60 minutes on a simple digital heat block. All reagents were prepared in a PCR chamber and experiments were performed in a unidirectional flow process with precautionary measures observed to avoid cross-contamination. Analysis of Reaction Products Five microliters of HBV-LAMP products was electrophoretically analyzed on 2.8% agarose gel stained with GelRed DNA intercalating dye (Phenix Research, Candler, North Carolina), run in 1× TAE buffer at 100 volts for 50–55 minutes, and visualized with a UV transilluminator at 302 nm. Amplification products were also visualized in the original reaction tube by adding 0.5 µL of a 10× GelGreen fluorescence dye (Phenix Research) to 10 µL of LAMP reaction products, visualized with a UV transilluminator at 302 nm, and photographed with the BlackBerry Bold (Research In Motion) and the iPad Air (Apple, Inc) cameras. Analytical Sensitivity and Specificity of HBV-LAMP Assay Analytical sensitivity was evaluated by testing 10-fold serial dilutions of HBV DNA. The assay detection limit was determined by analysis of 4–7 replicates of serially diluted HBV DNA (OptiQuant HBV DNA Quantification Panel). The analytical specificity of the HBV-LAMP assay was investigated by testing HBV-specific primers against DNA (approximately 30 ng) extracted from cytomegalovirus (CMV)–positive and parvovirus (PV)–positive plasma specimens. Specificity of the HBV oligonucleotides was further evaluated by testing DNA (approximately 50 ng) of Leishmania major, Leishmania tropica, and Trypanosoma cruzi (kindly provided by Dr Robert Duncan and Carolyn Fisher of the US Food and Drug Administration [FDA], Bethesda, Maryland). Assay Diagnostic Sensitivity and Specificity The diagnostic sensitivity and specificity of HBV-LAMP assay was investigated by blind testing a total of 182 donor plasma specimens that were preselected using the Procleix Ultrio assay (Gen-Probe, Emeryville, California). Time-point of Assay Detection To determine the time-point at which HBV DNA is amplified by the LAMP assay, time-course amplification studies were performed at 10-, 20-, 30-, 40-, and 60-minute time-points using 50 and 100 IU of HBV DNA per reaction. At the end of the indicated time-points, reaction tubes containing HBV DNA were removed from the heat block and placed on ice to terminate the reaction. RESULTS Detection of HBV DNA HBV DNA extracted from plasma standards of various HBV genotypes were used in the assay. Electrophoretic analysis of the LAMP products demonstrated successful detection of all 6 major HBV genotypes (A–F) with a universal set of HBV-LAMP primers (Figure 2A). The LAMP reaction resulted in a unique laddering pattern of amplicons common to all genotypes detected (Figure 2A). UV visualization of LAMP products with GelGreen dye revealed a greenish-fluorescent glow in the reaction tubes that were positive for amplified HBV DNA (Figure 2B). No fluorescent reaction or laddering pattern was observed for the no-template (water) control or the normal human plasma (Figure 2A and 2B). Figure 2. Open in new tabDownload slide Detection of hepatitis B virus (HBV) DNA in plasma. Genomic DNA was extracted from a plasma standard panel containing HBV genotypes A–F and subjected to isothermal amplification using a universal primer set. A, Result of agarose gel analysis showed detection of all genotypes tested as demonstrated by ladder-like banding pattern common to all genotypes. B, Addition of GelGreen fluorescent dye to reaction tubes revealed a greenish fluorescent color in tubes with amplified HBV DNA (tubes A–F). Lane M = 50 bp marker (Bionexus); lanes A–F = HBV genotypes A–F. Abbreviations: HBV, hepatitis B virus; M, 100 bp marker; NP, negative plasma; NTC, no template (water) control. Figure 2. Open in new tabDownload slide Detection of hepatitis B virus (HBV) DNA in plasma. Genomic DNA was extracted from a plasma standard panel containing HBV genotypes A–F and subjected to isothermal amplification using a universal primer set. A, Result of agarose gel analysis showed detection of all genotypes tested as demonstrated by ladder-like banding pattern common to all genotypes. B, Addition of GelGreen fluorescent dye to reaction tubes revealed a greenish fluorescent color in tubes with amplified HBV DNA (tubes A–F). Lane M = 50 bp marker (Bionexus); lanes A–F = HBV genotypes A–F. Abbreviations: HBV, hepatitis B virus; M, 100 bp marker; NP, negative plasma; NTC, no template (water) control. Analytical and Diagnostic Sensitivity of HBV-LAMP Assay Assay sensitivity was evaluated by testing 10-fold serial dilutions of HBV DNA in the LAMP reaction. The assay detected down to 10 IU per reaction of HBV DNA (Figure 3A). Addition of GelGreen fluorescent dye to the reaction tubes revealed a fluorescent glow with decreasing intensity from 104 to 0.1 IU/reaction (Figure 3B). Also, donor plasma samples (n = 75) were tested to evaluate the diagnostic sensitivity of the assay. Test results revealed that the assay detected 69 of 75 (92%) as HBV positive (Table 1). The undetected samples (n = 6) had DNA levels below the assay detection limit (approximately 7–10 IU/reaction). Table 1. Clinical Plasma Specimens Evaluated by the Hepatitis B Virus Loop-Mediated Isothermal Amplification Assay Detection Method . DNA Extraction . DNA Amplification . Sensitivity . Specificity . . Plasma Volume, µL . Reaction Volume, µL . Input Volume, µL . HBV-Positive Plasma . Healthy/Negative Human Plasma . Total Specimens Tested . HBV-LAMP 400 25 10 69/75 (92%) 107/107 (100%) 182 Procleix Ultrioa 500 >500 500 75/75 (100%) 107/107 (100%) 182 Detection Method . DNA Extraction . DNA Amplification . Sensitivity . Specificity . . Plasma Volume, µL . Reaction Volume, µL . Input Volume, µL . HBV-Positive Plasma . Healthy/Negative Human Plasma . Total Specimens Tested . HBV-LAMP 400 25 10 69/75 (92%) 107/107 (100%) 182 Procleix Ultrioa 500 >500 500 75/75 (100%) 107/107 (100%) 182 Results of donor plasma tested by HBV-LAMP assay. Test results of HBV-positive donor plasma normal human plasma specimens evaluated by the LAMP reaction. Abbreviations: HBV, hepatitis B virus; LAMP, loop-mediated isothermal amplification. a Procleix sensitivity not absolute; based on positive donor cohort. Open in new tab Table 1. Clinical Plasma Specimens Evaluated by the Hepatitis B Virus Loop-Mediated Isothermal Amplification Assay Detection Method . DNA Extraction . DNA Amplification . Sensitivity . Specificity . . Plasma Volume, µL . Reaction Volume, µL . Input Volume, µL . HBV-Positive Plasma . Healthy/Negative Human Plasma . Total Specimens Tested . HBV-LAMP 400 25 10 69/75 (92%) 107/107 (100%) 182 Procleix Ultrioa 500 >500 500 75/75 (100%) 107/107 (100%) 182 Detection Method . DNA Extraction . DNA Amplification . Sensitivity . Specificity . . Plasma Volume, µL . Reaction Volume, µL . Input Volume, µL . HBV-Positive Plasma . Healthy/Negative Human Plasma . Total Specimens Tested . HBV-LAMP 400 25 10 69/75 (92%) 107/107 (100%) 182 Procleix Ultrioa 500 >500 500 75/75 (100%) 107/107 (100%) 182 Results of donor plasma tested by HBV-LAMP assay. Test results of HBV-positive donor plasma normal human plasma specimens evaluated by the LAMP reaction. Abbreviations: HBV, hepatitis B virus; LAMP, loop-mediated isothermal amplification. a Procleix sensitivity not absolute; based on positive donor cohort. Open in new tab Figure 3. Open in new tabDownload slide Sensitivity and specificity of hepatitis B virus (HBV) loop-mediated isothermal amplification (LAMP) assay primers. A, Serial dilutions of HBV DNA were tested in HBV-LAMP to evaluate the assay sensitivity. Electrophoretic analysis demonstrated detection of 10 IU of HBV DNA. Lane M = 100 bp marker (Invitrogen). B, Addition of GelGreen fluorescent dye to the reaction tubes revealed a fluorescent glow with decreasing intensity from 104 to 0.1 IU/reaction. C, DNA was extracted from cytomegalovirus (CMV)–positive and parvovirus (PV)–positive donor plasma specimens and subjected to LAMP reaction. Results of the HBV-LAMP assay revealed no amplification of CMV and PV DNAs, but detected only HBV DNA. Lane M = 100 bp DNA ladder; lane 1 = NTC; lanes 2 and 3 = CMV DNA; lanes 4 and 5 = PV DNA; lanes 6 and 7 = HBV-A DNA. D, HBV-LAMP reaction using DNAs of parasites revealed no detection of Trypanosomacruzi (lanes 3 and 4), Leishmania major (lanes 5 and 6), and Leishmania tropica (lanes 7 and 8) DNA; lane 1 = 100 bp marker; lane 2 = NTC; lane 3 = negative human plasma. Abbreviations: CMV, cytomegalovirus; HBV, hepatitis B virus; M, 100 bp marker; NP, negative human plasma; NTC, no-template control; PV, parvovirus; rxn, reaction. Figure 3. Open in new tabDownload slide Sensitivity and specificity of hepatitis B virus (HBV) loop-mediated isothermal amplification (LAMP) assay primers. A, Serial dilutions of HBV DNA were tested in HBV-LAMP to evaluate the assay sensitivity. Electrophoretic analysis demonstrated detection of 10 IU of HBV DNA. Lane M = 100 bp marker (Invitrogen). B, Addition of GelGreen fluorescent dye to the reaction tubes revealed a fluorescent glow with decreasing intensity from 104 to 0.1 IU/reaction. C, DNA was extracted from cytomegalovirus (CMV)–positive and parvovirus (PV)–positive donor plasma specimens and subjected to LAMP reaction. Results of the HBV-LAMP assay revealed no amplification of CMV and PV DNAs, but detected only HBV DNA. Lane M = 100 bp DNA ladder; lane 1 = NTC; lanes 2 and 3 = CMV DNA; lanes 4 and 5 = PV DNA; lanes 6 and 7 = HBV-A DNA. D, HBV-LAMP reaction using DNAs of parasites revealed no detection of Trypanosomacruzi (lanes 3 and 4), Leishmania major (lanes 5 and 6), and Leishmania tropica (lanes 7 and 8) DNA; lane 1 = 100 bp marker; lane 2 = NTC; lane 3 = negative human plasma. Abbreviations: CMV, cytomegalovirus; HBV, hepatitis B virus; M, 100 bp marker; NP, negative human plasma; NTC, no-template control; PV, parvovirus; rxn, reaction. Analytical and Diagnostics Specificity of HBV-LAMP Assay The analytical specificity of the HBV-LAMP assay was investigated by testing DNA of CMV and PV, respectively. Electrophoretic analysis of test results revealed no detection (Figure 3C). Also, specificity of the HBV oligonucleotides was evaluated by testing DNA of L. major, L. tropica, and T. cruzi in the LAMP assay. Results of the test also demonstrated no detection (Figure 3D). To assess the diagnostic specificity of the assay, healthy human plasma specimens (n = 107) were tested and all samples tested negative (100%) by the HBV-LAMP assay (Table 1). Evaluation of HBV-LAMP Assay To determine the field and clinical utility of the HBV-LAMP assay, experiments were conducted using donor plasma specimens from which DNA was extracted. Aliquots of the identical plasma samples were also heat-treated (without DNA extraction) and directly tested in the LAMP reaction. The results of agarose-gel electrophoresis demonstrated detection of HBV DNA using both extracted DNA and heat-treated plasma samples (Supplementary Figure 1). The assay detected 2 additional samples (numbers 15 and 21) when extracted DNA was used, suggesting that the assay is more sensitive under those conditions. Limit of Detection To determine the limit of detection of the HBV-LAMP assay, 4–7 replicates of serially diluted HBV DNA that was extracted from the OptiQuant HBV DNA quantification plasma panel (AcroMetrix/Life Technologies) were assayed and analyzed. Results revealed a 100% detection rate for 25, 50, 102, 103, and 104 IU of HBV DNA molecules per reaction, whereas 1 IU and 10 IU of HBV DNA was detected at 25% and 57% rates, respectively (Table 2). Table 2. Probit Data on Loop-Mediated Isothermal Amplification Assay HBV DNA, IU/Reaction . Replicates Tested in Reaction . No. of Times Detected . Rate of Detection, % . 104 7 7 100 103 7 7 100 102 7 7 100 50 7 7 100 25 7 7 100 10 7 4 57 1 4 1 25 0.1 4 0 0 HBV DNA, IU/Reaction . Replicates Tested in Reaction . No. of Times Detected . Rate of Detection, % . 104 7 7 100 103 7 7 100 102 7 7 100 50 7 7 100 25 7 7 100 10 7 4 57 1 4 1 25 0.1 4 0 0 Probit data of test performed on various concentrations of HBV DNA by the HBV loop-mediated isothermal amplification assay. Abbreviation: HBV, hepatitis B virus. Open in new tab Table 2. Probit Data on Loop-Mediated Isothermal Amplification Assay HBV DNA, IU/Reaction . Replicates Tested in Reaction . No. of Times Detected . Rate of Detection, % . 104 7 7 100 103 7 7 100 102 7 7 100 50 7 7 100 25 7 7 100 10 7 4 57 1 4 1 25 0.1 4 0 0 HBV DNA, IU/Reaction . Replicates Tested in Reaction . No. of Times Detected . Rate of Detection, % . 104 7 7 100 103 7 7 100 102 7 7 100 50 7 7 100 25 7 7 100 10 7 4 57 1 4 1 25 0.1 4 0 0 Probit data of test performed on various concentrations of HBV DNA by the HBV loop-mediated isothermal amplification assay. Abbreviation: HBV, hepatitis B virus. Open in new tab Time-point of Detection One of the advantages of the LAMP assay is its rapid detection process. To evaluate the earliest time-point at which detection occurs, amplification of HBV DNA was tested at defined time intervals. Results of experiments revealed that the assay detection of 50 IU of HBV DNA appeared at the 30-minute time-point, and 100 IU of HBV DNA was detected at the 20-minute time-point (Supplementary Figure 2). Stability of Reaction Buffer The stability of the MAB was evaluated as described above. Electrophoretic analysis showed successful amplification of 25 IU/reaction of HBV DNA using fresh buffer regularly stored at −20°C, 10 IU/reaction of HBV DNA when room temperature–stored buffer (22–25°C) was used, and 50 IU/reaction HBV DNA when accelerated-aged buffer was used (Supplementary Figure 3). DISCUSSION The prevalence of HBV infection in underprivileged communities and regions of the world has generated heightened concerns in healthcare circles worldwide [20–25]. HBV screening and diagnosis in resource-limited environments is often a challenging situation, because of time and cost limitations, thus leaving infected individuals undiagnosed for several years. This underscores the need for a simple and rapid diagnostic and screening tool that is applicable not only in resource-limited settings, but also in any region of the world with high prevalence of HBV infections [26–28]. In developed settings, the HBV-LAMP assay could be useful to verify that a patient undergoing HBV treatment has achieved full virological suppression. In the present study, we developed and validated a sensitive and rapid isothermal amplification assay for pan-detection of HBV genotypes (A–F) in plasma specimens (Figure 2). The HBV-LAMP assay offers several advantages over conventional “gold standard” methods such as real-time PCR or ELISA: (i) the assay does not require sophisticated equipment and costly reagents, (ii) it requires less time (<60 minutes) to conduct, and (iii) it is performed on a simple digital heat block, without the need for high technical expertise. Thus, in regions with struggling national economies and lack of high-tech diagnostic equipment, these advantages make the HBV-LAMP assay well suited for use in such resource-limited settings for blood screening and diagnosis of HBV infection. The sensitivity of the HBV-LAMP assay was evaluated to assess its clinical and field applicability, using characterized standards and blinded clinical plasma specimens. Compared with the FDA-licensed Procleix Ultrio Plus dHBV test, the HBV-LAMP assay detected 69 of 75 (92%) HBV-positive donor plasma specimens (Table 1); the assay sensitivity approaches 100% with the use of fluorophores for detection (data not shown). As shown by the Probit data in Table 2, the LAMP assay also revealed a 100% detection rate for 25, 50, 102, 103, and 104 IU of HBV DNA per reaction, whereas 1 IU and 10 IU of HBV-DNA was detected at 25% and 57% rates, respectively. These findings suggest that the LAMP assay performed efficiently when used in testing and analysis of clinical specimens for HBV infection. Sample enrichment and volume play a critical role in detection sensitivity. For example, the Procleix Ultrio assay utilizes an automated target capture specimen-processing method and employs higher volumes [29] (see packet insert]. On the other hand, the HBV-LAMP assay used a smaller starting volume for nucleic acid extraction and a smaller input volume for amplification, yet yielding a sensitivity of 92% (Table 1). Thus, given its plausible performance vis-à-vis the clinical and epidemiological relevance of HBV infection, the HBV-LAMP assay is potentially applicable in field environment and in clinical settings for screening and rapid detection of HBV infection. Notably, the LAMP assay also successfully detected HBV DNA in heat-treated plasma (Supplementary Figure 1B), irrespective of the possible presence of potential amplification inhibitory substances that are found in blood products [30, 31]. This method of template preparation (as opposed to nucleic acid extraction) contributed to the rapidity of the assay and simplified the detection process (Supplementary Figure 1 and 3D). However, an increase in the volume of starting material from 25 µL to a larger volume (eg, 100 µL) may be necessary to improve the sensitivity of detection when using heat-treated plasma for the reaction. Further investigation of this method may prove helpful in resource-limited environments to facilitate the test at lower cost and ease. In consideration of detection specificity and accuracy in clinical diagnostics, primers in this LAMP assay were designed that specifically targeted conserved sequences of the S gene and overlapping polymerase regions that show about 96% sequence identity and homology across the HBV genotypes [32]. As shown in Figure 2, the LAMP assay detected various HBV genotypes (A–F), thereby demonstrating its global coverage of HBV detection. When healthy donor plasma samples (n = 107) were tested, the HBV-LAMP assay revealed a diagnostic specificity of 100% as no amplification of HBV DNA was observed in these specimens (Table 1). This characteristic of the HBV-LAMP assay was also confirmed by its detection of only the target HBV DNA without cross-reaction with CMV, PV, T. cruzi, or the Leishmania species (Figures 3C and 3D). Within the context of today's globalization, people have been moving across international borders either for sociopolitical/socioeconomic reasons or for recreational purposes [33–35]. This rapid trend of human migration has influenced the spread of viral hepatitis and its changing epidemiology from Afghanistan to Pakistan, from the Indian subcontinent and Asia to the eastern Mediterranean, North Africa, and the United States [34, 36–38]. Hence, the severity and prevalence of HBV emphasizes the need for a rapid and affordable diagnostic screening tool as reported in this study, which could be used to investigate HBV prevalence in different regions of the world. A noteworthy advantage of the LAMP assay reported in this study is its use of a thermostable reaction buffer (MAB) and the Bst DNA polymerase, 2 major components that allowed preparation of reaction mixture at room temperature as well as performance of amplification under isothermal conditions without compromising sensitivity. It is well established that Bst DNA polymerase has DNA strand displacement activity, whereas l-proline has a destabilizing effect on the DNA double helix, lowers the melting temperature of DNA, confers salinity tolerance, and aids in DNA polymerase stability [12–14]. In addition, d-mannitol, a hygroscopic and osmopotent material, also promoted buffer stability and robustness under thermostressed conditions [39, 40]. As demonstrated by the accelerated stability tests, the MAB surprisingly retained a considerable level of stability and robustness (Supplementary Figure 3A–C). The advent of nucleic acid amplification tests in clinical diagnosis and donor blood screening brought tremendous improvement by ensuring safety of blood products and prevention of disease transmission. Yet, diagnostic tools such as PCR-based tests have inherent limitations that include the lack of rapidity, laborious performance process, use of cumbersome equipment, and being easily prone to contamination [41, 42]. In contrast, the HBV-LAMP assay demonstrates ease of performance, rapidity, sensitivity, and the use of multiple primers that makes the assay highly specific and less liable to cross-contamination. The assay detected 50 IU of HBV DNA in 30 minutes, thereby reducing the reaction time for detection (Supplementary Figure 2). These advantages of the HBV-LAMP assay could contribute to filling gaps seen in transfusion medicine in resource-limited settings. Although we did not further investigate the assay's time-course of detection using a lower amount or concentration of DNA, it is plausible to suggest that the entire 60-minute reaction time may be required to detect a smaller quantity of DNA (approximately 10 IU/reaction) as shown in Figure 3A and Supplementary Figure 3B. Also, field studies would be necessary to confirm the reliability of the assay in developing world-settings. Considered in aggregate, the HBV-LAMP detection assay reported in this study is rapid, simple to use, and specific. Mostly applicable in environments with scarcity of medical diagnostics resources, the HBV-LAMP assay could be used for blood screening and detection of HBV infection in highly endemic populations and for therapeutic monitoring of patients undergoing antiviral treatment. Supplementary Data Supplementary materials are available at Clinical Infectious Diseases online (http://cid.oxfordjournals.org). Supplementary materials consist of data provided by the author that are published to benefit the reader. The posted materials are not copyedited. The contents of all supplementary data are the sole responsibility of the authors. Questions or messages regarding errors should be addressed to the author. Notes Acknowledgments. The authors thank Celso Bianco, MD, Alain Debrabant, PhD, and Ranadhir Dey, PhD, for their critical and intellectual review of the manuscript. We also thank Livia Alves Lima and Elizabeth Martinez for their valuable technical assistance. Disclaimer. The findings and conclusions of this study have not been formally disseminated by the Food and Drug Administration (FDA) and should not be construed as representative of any policy or agency determination of the FDA and the US Department of Health and Human Services. Financial support. This work was supported in part by an appointment to the Research Participation Program at the Center for Biologics Evaluation and Research administered by the Oak Ridge Institute for Science and Education through an interagency agreement between the Department of Energy and the FDA. Potential conflicts of interest. All authors: No reported conflicts. All authors have submitted the ICMJE Form for Disclosure of Potential Conflicts of Interest. Conflicts that the editors consider relevant to the content of the manuscript have been disclosed. References 1 Liang TJ . Hepatitis B: the virus and diseases , Hepatology , 2009 , vol. 49 5 suppl (pg. S13 - 21 ) Google Scholar Crossref Search ADS PubMed WorldCat 2 Arababadi MK , Pourfathollah AA , Jafarzadeh A , et al. Hepatitis B virus genotype, HBsAg mutations and co-infection with HCV in occult HBV infection , Clin Res Hepatol Gastroenterol , 2011 , vol. 35 (pg. 554 - 9 ) Google Scholar Crossref Search ADS PubMed WorldCat 3 Kim MJ , Park Q , Min HK , et al. Residual risk of transfusion-transmitted infection with human immunodeficiency virus, hepatitis C virus, and hepatitis B virus in Korea from 2000 through 2010 , BMC Infect Dis , 2012 , vol. 12 pg. 160 Google Scholar Crossref Search ADS PubMed WorldCat 4 Okamoto H , Tsuda F , Sakugawa H , et al. Typing hepatitis B virus by homology in nucleotide sequence: comparison of surface antigen subtypes , J Gen Virol , 1988 , vol. 69 (pg. 2575 - 83 ) Google Scholar Crossref Search ADS PubMed WorldCat 5 Wai CT , Fontana RJ . Clinical significance of hepatitis B virus genotypes, variants, and mutants , Clin Liver Dis , 2004 , vol. 8 (pg. 321 - 52 ) Google Scholar Crossref Search ADS PubMed WorldCat 6 Wong VW , Sung JJ . Diagnosis and personalized management of hepatitis B including significance of genotypes , Curr Opin Infect Dis , 2012 , vol. 25 (pg. 570 - 7 ) Google Scholar Crossref Search ADS PubMed WorldCat 7 Franco E , Bagnato B , Marino MG , et al. Hepatitis B: epidemiology and prevention in developing countries , World J Hepatol , 2012 , vol. 4 (pg. 74 - 80 ) Google Scholar Crossref Search ADS PubMed WorldCat 8 Ott JJ , Stevens GA , Groeger J , Wiersma ST . Global epidemiology of hepatitis B virus infection: new estimates of age-specific HBsAG seroprevalence and endemicity , Vaccine , 2012 , vol. 30 (pg. 2212 - 9 ) Google Scholar Crossref Search ADS PubMed WorldCat 9 Caliendo AM , Valsamakis A , Bremer JW , et al. Multilaboratory evaluation of real-time PCR tests for hepatitis B virus DNA quantification , J Clin Microbiol , 2011 , vol. 49 (pg. 2854 - 8 ) Google Scholar Crossref Search ADS PubMed WorldCat 10 Kao JH . Diagnosis of hepatitis B virus infection through serological and virological markers , Expert Rev Gastroenterol Hepatol , 2008 , vol. 2 (pg. 553 - 62 ) Google Scholar Crossref Search ADS PubMed WorldCat 11 Wang F , Ma C , Zeng X , et al. Chemiluminescence molecular detection of sequence-specific HBV-DNA using magnetic nanoparticles , J Biomed Nanotechnol , 2012 , vol. 8 (pg. 786 - 90 ) Google Scholar Crossref Search ADS PubMed WorldCat 12 Walker GT , Fraiser MS , Schram JL , et al. Strand displacement amplification--an isothermal, in vitro DNA amplification technique , Nucleic Acids Res , 1992 , vol. 20 (pg. 1691 - 6 ) Google Scholar Crossref Search ADS PubMed WorldCat 13 Walker GT . Empirical aspects of strand displacement amplification , PCR Methods Appl , 1993 , vol. 3 (pg. 1 - 6 ) Google Scholar Crossref Search ADS PubMed WorldCat 14 Rajendrakumar CS , Suryanarayana T , Reddy AR . DNA helix destabilization by proline and betaine: possible role in the salinity tolerance process , FEBS Lett , 1997 , vol. 410 (pg. 201 - 5 ) Google Scholar Crossref Search ADS PubMed WorldCat 15 Notomi T , Okayama H , Masubuchi H , et al. Loop-mediated isothermal amplification of DNA , Nucleic Acids Res , 2000 , vol. 28 pg. e63 Google Scholar Crossref Search ADS PubMed WorldCat 16 Moslemi E , Shahhosseiny MH , Javadi G , et al. Loop mediated isothermal amplification (LAMP) for rapid detection of HBV in Iran , Afr J Microbiol Res , 2009 , vol. 3 (pg. 439 - 45 ) Google Scholar OpenURL Placeholder Text WorldCat 17 Pan L , Zhang L , Wang G , Liu Q , et al. Rapid, simple and sensitive detection of ompB gene of spotted fever group rickettsiae by loop-mediated isothermal amplification , BMC Infect Dis , 2012 , vol. 12 pg. 254 Google Scholar Crossref Search ADS PubMed WorldCat 18 Kuboki N , Inoue N , Sakurai T , et al. Loop-mediated isothermal amplification for detection of African trypanosomes , J Clin Microbiol , 2003 , vol. 41 (pg. 5517 - 24 ) Google Scholar Crossref Search ADS PubMed WorldCat 19 Zhang X , Liao M , Jiao P , et al. Development of a loop-mediated isothermal amplification assay for rapid detection of subgroup J avian leukosis virus , J Clin Microbiol , 2010 , vol. 48 (pg. 2116 - 21 ) Google Scholar Crossref Search ADS PubMed WorldCat 20 Kiire CF . Hepatitis B infection in sub-Saharan Africa. The African Regional Study Group , Vaccine , 1990 , vol. 8 suppl (pg. S107 - 12 ) S134–8 Google Scholar Crossref Search ADS PubMed WorldCat 21 Stroffolini T , Almasio PL , Sagnelli E , et al. Evolving clinical landscape of chronic hepatitis B: a multicenter Italian study , J Med Virol , 2009 , vol. 81 (pg. 1999 - 2006 ) Google Scholar Crossref Search ADS PubMed WorldCat 22 Lu J , Xu A , Wang J , et al. Direct economic burden of hepatitis B virus related diseases: evidence from Shandong, China , BMC Health Serv Res , 2013 , vol. 13 pg. 37 10.1186/1472-6963-13-37 Google Scholar Crossref Search ADS PubMed WorldCat 23 Thornley S , Bullen C , Roberts M , et al. Hepatitis B in a high prevalence New Zealand population: a mathematical model applied to infection control policy , J Theor Biol , 2008 , vol. 254 (pg. 599 - 603 ) Google Scholar Crossref Search ADS PubMed WorldCat 24 Chen LH , Barnett ED , Wilson ME , et al. Hepatitis B screening in US travelers seen at the Boston area travel medicine network , J Travel Med , 2013 , vol. 20 (pg. 29 - 36 ) Google Scholar Crossref Search ADS PubMed WorldCat 25 Sharif O , Krishnan PV , Thekdi AD , et al. Acute hepatitis B in an urban tertiary care hospital in the United States: a cohort evaluation , J Clin Gastroenterol , 2013 , vol. 47 (pg. e87 - 90 ) Google Scholar Crossref Search ADS PubMed WorldCat 26 Jain R , Aggarwal P , Gupta GN , et al. Need for nucleic acid testing in countries with high prevalence of transfusion-transmitted infections , ISRN Hematol , 2012 , vol. 2012 pg. 718671 Google Scholar Crossref Search ADS PubMed WorldCat 27 Shastry S , Bhat SS . Prevention of post-transfusion hepatitis by screening of antibody to hepatitis B core antigen in healthy blood donors , Mediterr J Hematol Infect Dis , 2011 , vol. 3 pg. e2011062 Google Scholar Crossref Search ADS PubMed WorldCat 28 Stramer SL , Wend U , Candotti D , et al. Nucleic acid testing to detect HBV infection in blood donors , N Engl J Med , 2011 , vol. 364 (pg. 236 - 47 ) Google Scholar Crossref Search ADS PubMed WorldCat 29 Ginocchio CC . Life beyond PCR: alternative target amplification technologies for the diagnosis of infectious diseases, part II , Clin Microbiol Newsletter , 2004 , vol. 26 (pg. 129 - 36 ) Google Scholar Crossref Search ADS WorldCat 30 Al-Soud WA , Jönsson LJ , Râdström P . Identification and characterization of immunoglobulin G in blood as a major inhibitor of diagnostic PCR , J Clin Microbiol , 2000 , vol. 38 (pg. 345 - 50 ) Google Scholar PubMed OpenURL Placeholder Text WorldCat 31 Al-Soud WA , Rådström P . Purification and characterization of PCR-inhibitory components in blood cells , J Clin Microbiol , 2001 , vol. 39 (pg. 485 - 93 ) Google Scholar Crossref Search ADS PubMed WorldCat 32 Osiowy C , Giles E . Evaluation of the INNO-LiPA HBV genotyping assay for determination of hepatitis B virus genotypes , J Clin Microbiol , 2003 , vol. 41 (pg. 5473 - 7 ) Google Scholar Crossref Search ADS PubMed WorldCat 33 Bos P , Steele AD , Peenze I , Aspinall S . Sero-positive to hepatitis B and C virus infection in refugees from Mozambique in southern Africa , East Afr Med J , 1995 , vol. 72 (pg. 113 - 5 ) Google Scholar PubMed OpenURL Placeholder Text WorldCat 34 Quddus A , Luby SP , Jamal Z , Jafar T . Prevalence of hepatitis B among Afghan refugees living in Balochistan, Pakistan , Int J Infect Dis , 2006 , vol. 10 (pg. 242 - 7 ) Google Scholar Crossref Search ADS PubMed WorldCat 35 Johnson DF , Leder K , Torresi J . Hepatitis B and C infection in international travelers , J Travel Med , 2013 , vol. 20 (pg. 194 - 202 ) Google Scholar Crossref Search ADS PubMed WorldCat 36 Zhender G , Ebranati E , Gabanelli E , et al. Spatial and temporal dynamics of hepatitis B virus D genotype in Europe and the Mediterranean basin , PLoS One , 2012 , vol. 7 pg. e7198 Google Scholar OpenURL Placeholder Text WorldCat 37 Ward JW , Byrd KK . Hepatitis B in the United States: a major health disparity affecting many foreign-born populations , Hepatology , 2012 , vol. 56 (pg. 419 - 21 ) Google Scholar Crossref Search ADS PubMed WorldCat 38 Kowdley KV , Wang CC , Welch S , et al. Prevalence of chronic hepatitis B among foreign-born persons living in the United States by country of origin , Hepatology , 2012 , vol. 56 (pg. 422 - 33 ) Google Scholar Crossref Search ADS PubMed WorldCat 39 Dittmar JH , Brothers A . Hygroscopicity of sugars and sugar mixtures , Ind Eng Chem , 1935 , vol. 27 (pg. 333 - 5 ) Google Scholar Crossref Search ADS WorldCat 40 Ohrem HL , Schornick E , Kalivoda A , et al. Why is mannitol becoming more and more popular as a pharmaceutical excipient in solid dosage forms? , Pharm Dev Technol , 2014 , vol. 19 (pg. 257 - 62 ) Google Scholar Crossref Search ADS PubMed WorldCat 41 Corless CE , Guiver M , Borrow R , et al. Contamination and sensitivity issues with a real-time universal 16S rRNA PCR , J Clin Microbiol , 2000 , vol. 38 (pg. 1747 - 52 ) Google Scholar PubMed OpenURL Placeholder Text WorldCat 42 Meier A , Persing D , Finken M , et al. Elimination of contaminating DNA within polymerase chain reaction reagents: implication for a general approach to detection of uncultured pathogens , J Clin Microbiol , 1993 , vol. 31 (pg. 646 - 52 ) Google Scholar PubMed OpenURL Placeholder Text WorldCat Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US. TI - Rapid Detection of Hepatitis B Virus in Blood Plasma by a Specific and Sensitive Loop-Mediated Isothermal Amplification Assay JF - Clinical Infectious Diseases DO - 10.1093/cid/ciu210 DA - 2014-07-01 UR - https://www.deepdyve.com/lp/oxford-university-press/rapid-detection-of-hepatitis-b-virus-in-blood-plasma-by-a-specific-and-QdVC0RM4LE SP - 16 EP - 23 VL - 59 IS - 1 DP - DeepDyve ER -