TY - JOUR AU - Wei, Yuechen AB - The submersible mixer is used as the research object to study the influence of its installation position on the mixing effect. Based on CFD calculation software, the standard k- equation is used to simulate the internal flow field of the submersible mixer under different installation position conditions. The results show that the installation position is better in the diagonal than the installation position is in the same horizontal line, and the increase of viscosity of the working medium will increase the power consumed by the mixing device. TI - Effect of installation positions on the mixing performance of submersible mixers in wastewater treatment JF - Proceedings of SPIE DO - 10.1117/12.2647066 DA - 2022-09-07 UR - https://www.deepdyve.com/lp/spie/effect-of-installation-positions-on-the-mixing-performance-of-MV55CQucsI SP - 123293W EP - 123293W-4 VL - 12329 IS - DP - DeepDyve ER -