TY - JOUR AU1 - Choi,, Pyuck-Pa AU2 - Kwon,, Young-Soon AU3 - Kim,, Ji-Soon AU4 - Al-Kassab,, Tala’at AB - Abstract The preparation of transmission electron microscopy (TEM) and atom probe-field ion microscopy (AP-FIM) specimens from mechanically alloyed Ti-Cu-Ni-Sn powder has been explored. Applying the focused ion beam (FIB) based in situ lift-out technique, it has been demonstrated that specimen preparation can be carried on single micrometre-sized powder particles without the use of any embedding media. Since the particles did not incorporate any micropores, as revealed by cross-sectioning, the standard procedure known for bulk samples could be simply implemented to the powder material. A sequence of rectangular cuts and annular milling was found to be a highly efficient way of forming a tip-shaped AP-FIM specimen from a square cross-section blank. A Ga level ≤1 at.% was detected if a low beam current of 10 pA was chosen for the final ion-milling stages. Implanted Ga ions were mostly confined to a zone of about 2 nm in thickness and indicated that ion-induced structural transformations were negligible. transmission electron microscopy, field ion microscopy, atom probe, focused ion beam, in-situ lift-out, powder materials Introduction Mechanical alloying (MA) by means of ball milling is a well-known method of circumventing the limitations of conventional alloying and producing novel types of materials. During ball milling, powder particles (typically between 1 and 100 μm in size) are subjected to severe plastic deformation and repeated fracture and cold-welding processes. Metastable materials such as highly supersaturated solid solutions, chemically disordered intermetallics, nanocrystalline and amorphous alloys, etc. can be prepared in this way [1,2]. Owing to their unique microstructure, mechanically alloyed powders have been widely used as feedstock for the fabrication of bulk samples showing outstanding macroscopic properties. For instance, amorphous powders have been consolidated into high strength bulk amorphous alloys, which have great potential for engineering applications [3–5]. To gain a full understanding of the properties of the compacts, it is often essential to characterize the structure and elemental distribution of the initial powder on a sub-nanometre scale. This can be done applying transmission electron microscopy (TEM) in combination with atom probe–field ion microscopy (AP-FIM). In the case of fine micrometre-sized powder, however, such analyses are often hampered by the difficult specimen preparation. While for TEM investigations thin membranes of less than 1 μm in thickness are required, AP-FIM specimens must have the shape of a fine tip having a radius of curvature smaller than 100 nm. Conventional electropolishing methods can only be applied after the incorporation of powder particles in an embedding medium, which is time consuming and does not always guarantee a high success rate. Therefore, more efficient and generally applicable specimen preparation techniques need to be developed. Focused ion beam (FIB) milling has received substantially growing attention as a sophisticated instrument for TEM [6–17] and AP-FIM specimen preparation [18–23]. FIB has been of particular interest owing to the development of the lift-out technique, in which a selected part of the specimen is cross-sectioned and lifted out. This method is of particular interest for site-specific TEM [6–12,15,17] and AP-FIM [23] analyses but it has also been explored for the preparation of TEM specimens from micrometre-sized powders [16,17]. Although the lift-out method can be used for AP-FIM specimen preparation from powders as well, there has been no such report to our knowledge. Miller et al. [23] demonstrated that an individual powder particle can be positioned on a support using an ex situ manipulator and subsequently FIB milled to an AP-FIM tip. However, it was reported that this method is rather promising for particles larger than 100 μm. In the present study, TEM specimen preparation using the FIB lift-out technique has been reproduced for a mechanically alloyed Ti-Cu-Ni-Sn powder. Furthermore, a slight modification of the lift-out technique, which is described in [23], has been implemented for the preparation of the AP-FIM specimens from single powder particles. Methods A powder mixture having a nominal composition of Ti50Cu25Ni20Sn5 was mechanically alloyed for 20 h in a high-energy planetary ball mill (AGO-2) under protective Ar atmosphere. As-milled powder samples were characterized using X-ray diffraction (XRD). Only a broad halo peak, characteristic of an amorphous structure, was detected. The preparation of TEM and AP-FIM specimens was conducted with a dual beam FIB instrument (FEI, Nova Nanolab 600), using 30 keV Ga+ ions. This instrument allowed the specimen to be in situ manipulated with a needle-probe and also incorporated a gas injection system for ion-beam-assisted chemical vapour deposition. Powder samples for FIB were prepared by dusting a small portion onto double-stick carbon tape adhered to a specimen holder. Ion beam currents ranging from 1 to 7 nA were used for cross-sectioning the powder particles, while ion-milling of blanks to TEM and AP-FIM specimens was conducted at currents between 10 and 500 pA. TEM investigations were performed with a Philips EM 420T at an acceleration voltage of 120 kV. FIM images were obtained at a sample temperature of about 30 K, using neon at a partial pressure of 7 × 10−3 Pa as an imaging gas. Atom probe analyses were carried out with a tomographic atom probe. Details about the setup and operation of this type of apparatus are described elsewhere [24]. A sample temperature of 30 K, a pulse frequency of 1000 Hz and a pulse voltage to base voltage ratio of 20% were found to be appropriate acquisition parameters. Results and discussion Scanning electron micrographs revealed particle sizes of a few tens of micrometres for the studied powder [compare Fig. 1(a)–(h)]. Thus, the particles were large enough to be cross-sectioned for the application of the in situ lift-out technique. In the first step, a sacrificial Pt layer (of about 2 μm in thickness) was deposited on the centre of a selected particle [see Fig. 1(a)], protecting the particle surface against Ga implantation. Deep sloped trenches were milled on the front as well as on the back side of this Pt layer [see Fig. 1(b)], leaving behind a lamella of ∼20 μm × 10 μm × 2 μm in dimension. Cross-sectioning did not reveal the presence of any micrometre-sized pores inside the powder particles [see Fig. 1(c)], which may deteriorate the mechanical stability of the specimens. The lamellae were found to exhibit sloped side walls, which has been referred to in the literature as the classic V shape and was ascribed to the redeposition of sputtered material [15,25,26]. The lift-out of the lamella was performed with a sharp needle-probe according to a standard procedure as shown in Fig. 1(d)–(h). Ion-milling of the lamella to an electron transparent membrane was not performed prior to the lift-out, as thin membranes were susceptible to bending during attachment to the needle-probe. Thinning was done after attaching the lamella to a support, as illustrated in Fig. 2(a)–(f). Rectangular ion milling patterns and successively decreasing ion beam currents ranging from 500 to 50 pA were used. The lamella was slightly tilted into the ion beam to an incidence angle of 88° (with respect to the surface normal) in order to eliminate the V shape. Ion-milling was continued until the entire membrane was thinner than 200 nm. Regions close to its upper edge were particularly thin and electron transparent. Except for the Pt layer, no crystallites could be observed within the specimen. A diffraction pattern of a region not including the Pt layer only exhibited diffused rings (compare Fig. 3). These observations were in good agreement with previous XRD investigations. Fig. 1 Open in new tabDownload slide FIB-based in situ lift-out method of a TEM lamella from a single powder particle. Fig. 1 Open in new tabDownload slide FIB-based in situ lift-out method of a TEM lamella from a single powder particle. Fig. 2 Open in new tabDownload slide (a)–(c) Attachment of a lamella to a TEM specimen support. (d)–(e) Thinning of the lamella to an electron transparent membrane. Fig. 2 Open in new tabDownload slide (a)–(c) Attachment of a lamella to a TEM specimen support. (d)–(e) Thinning of the lamella to an electron transparent membrane. Fig. 3 Open in new tabDownload slide TEM image and selected area diffraction pattern of the specimen shown in Fig. 2. Fig. 3 Open in new tabDownload slide TEM image and selected area diffraction pattern of the specimen shown in Fig. 2. The first stages of AP-FIM specimen preparation were performed analogous to the TEM specimen preparation except that a square cross section blank was lifted out of a powder particle instead of the entire lamella [see Fig. 4(a)–(b)]. The blank was attached to a W support by depositing Pt on each side of the blank/substrate interface after 90° rotation. An efficient way of forming an AP-FIM specimen from the blank was found to be a sequence of rectangular and annular milling patterns. First, a thin post of ∼1 μm in width was prepared from the upper half of the blank [compare Fig. 4(c)–(f)]. Subsequently, the post was sharpened to a fine tip by annular ion-milling, where the inner and outer radius of the milling pattern was gradually decreased. Using this ion-milling sequence, machining of the entire blank was avoided and specimen preparation time was shortened. Protrusions resulting from undercutting the shank of the tip were usually small in dimension and could be easily removed in a separate step [compare Fig. 4(e) and (f)]. Fig. 4 Open in new tabDownload slide In situ lift-out of a cross-section blank from a single powder particle for AP-FIM specimen preparation. (a)–(c) Attachment of a blank positioned to a tungsten support. (c)–(f) Sharpening of the blank to a AP-FIM specimen using a sequence of rectangular and annular ion-milling patterns. Fig. 4 Open in new tabDownload slide In situ lift-out of a cross-section blank from a single powder particle for AP-FIM specimen preparation. (a)–(c) Attachment of a blank positioned to a tungsten support. (c)–(f) Sharpening of the blank to a AP-FIM specimen using a sequence of rectangular and annular ion-milling patterns. Specimens prepared in the above-described way exhibited substantially higher mechanical stability than specimens prepared by annular milling of the entire blank, as the latter often ruptured at the blank/substrate interface. Filling the annular gap between tip and remaining blank with Pt may be considered as a method of further enhancing the mechanical stability of the specimen. The elemental maps detected by atom probe show homogeneous distributions [see Fig. 5(a)] within the amorphous Ti-Cu-Ni-Sn alloy. Neither clusters nor any other kinds of chemical heterogeneities can be seen. This observation can be quantitatively confirmed by statistical χ2 tests [compare Fig. 5(b)]. The measured concentration frequency distributions do not significantly differ from binomial distributions and χ2 values do not exceed critical χa2 values corresponding to a significance level of 95%. It should be mentioned that the detected composition value exhibits a deviation from the nominal composition. While the low Ti concentration may be attributed to a compositional shift due to the sticking of powder particles to the milling tools during ball milling, the increased Ni and decreased Cu concentration values are probably artifacts of atom probe analysis. Cu exhibits a lower evaporation field strength than Ni [27]. Therefore, Cu atoms are expected to be preferentially field-evaporated and to be detected with a reduced concentration. Fig. 5 Open in new tabDownload slide (a) Elemental distribution maps as detected by a tomographic atom probe. (b) Measured concentration frequency distributions in comparison with binomial distributions. Fig. 5 Open in new tabDownload slide (a) Elemental distribution maps as detected by a tomographic atom probe. (b) Measured concentration frequency distributions in comparison with binomial distributions. One of the major concerns of FIB milling for TEM and AP-FIM specimen preparation has been the implantation of Ga ions, which induces lattice defects and can lead to the formation of an amorphous surface phase for high ion doses [15]. Therefore, special care must be taken that specimens are exposed to the lowest possible ion dose during imaging and ion-milling. In these studies, the beam current was reduced from 50 to 10 pA for a tip radius smaller than 200 nm. The mass spectrum and of a specimen sharpened to about 100 nm radius of curvature reveals only a small number of singly charged detected Ga ions [see Fig. 6(a)], where the total Ga content is about 0.5 at.%. Assuming that annular milling of a tip with a low shank angle occurs at a Ga incidence nearly parallel to the tip surface, this value is comparable to the estimated level of 0.7 at.% for Ga+ ions implanted into a 100 nm thick TEM specimen of Si at 30 keV and an incident angle of 87.5° [26]. Figure 6(b) shows the corresponding distribution map of the detected Ga ions. The initial Ga concentration is slightly elevated to ∼1 at.% and decreases to a value of 0.3 at.%. The thickness of the Ga rich surface region is about 2 nm. Taking into consideration that the first few atomic layers are field evaporated prior to atom probe analysis, the detected thickness of the Ga rich zone is in reasonable agreement with TRIM simulation results. As reported in [15], the longitudinal range of 30 keV Ga+ ions in Ti amounts to 6.3 nm at an incidence angle of 88°. Fig. 6 Open in new tabDownload slide (a) Detected mass spectrum (partly shown). (b) Corresponding Ga distribution map. Fig. 6 Open in new tabDownload slide (a) Detected mass spectrum (partly shown). (b) Corresponding Ga distribution map. The total content of detected Ga (0.5 at.%) is significantly lower than an implantation level of ∼2 at.% Ga, below which neither the crystallographic or chemical structure of Cu/Co multilayers was found to be affected [20]. Hence, the chemical homogeneity detected for the amorphous Ti-Cu-Ni-Sn alloy clearly results from the ball milling process and not from Ga implantation. Figure 7 shows the FIM image of a specimen taken at a voltage of 14 kV after field evaporation of the Ga rich surface layer. A disordered arrangement of spots is seen over the whole imaged area, which is characteristic of an amorphous structure and is in agreement with XRD and TEM results. Fig. 7 Open in new tabDownload slide FIM image of a specimen prepared by FIB milling. Fig. 7 Open in new tabDownload slide FIM image of a specimen prepared by FIB milling. Concluding remarks The present studies have shown that high-quality TEM and AP-FIM specimens can be prepared from mechanically alloyed powder materials applying FIB and the in situ lift-out technique. One of the major advantages of this method is that no embedding medium is required and specimens can be prepared from single powder particles. The lack of any micrometre-sized pores inside the powder particles facilitates the specimen preparation. The results of this work are strongly encouraging for a systematic characterization of a variety of mechanically alloyed powder materials using TEM and AP-FIM. This work was supported by the 2006 Research Fund of the University of Ulsan. References 1 Suryanarayana C . Mechanical alloying and milling , Progr. Mater. Sci. , 2001 , vol. 46 (pg. 1 - 184 ) Google Scholar Crossref Search ADS WorldCat 2 Zhang D L . Processing of advanced materials using high-energy mechanical milling , Progr. Mater. Sci. , 2004 , vol. 49 (pg. 537 - 560 ) Google Scholar Crossref Search ADS WorldCat 3 Kawamura Y , Kato H , Inoue A , Masumoto T . Full strength compacts by extrusion of glassy metal powder at the supercooled liquid state , Appl. Phys. Lett. , 1995 , vol. 67 (pg. 2008 - 2010 ) Google Scholar Crossref Search ADS WorldCat 4 Lee M H , Bae D H , Kim W T , Kim D H , Rozhkova E , Wheelock P B , Sordelet D J . Synthesis of Ni-based bulk amorphous alloys by warm extrusion of amorphous powders , J. Non-Cryst. Solids , 2003 , vol. 315 (pg. 89 - 96 ) Google Scholar Crossref Search ADS WorldCat 5 Kim H J , Lee J K , Shin S Y , Jeong H G , Kim D H , Bae J C . Cu-based bulk amorphous alloys prepared by consolidation of amorphous powders in the supercooled liquid region , Intermetallics , 2004 , vol. 12 (pg. 1109 - 1113 ) Google Scholar Crossref Search ADS WorldCat 6 Overwijk M H F , Van Den Heuvel F C , Bulle-Lieuwma C W T . Novel scheme for the preparation of transmission electron microscopy specimens with a focused ion beam , J. Vac. Sci. Technol. B , 1993 , vol. 11 6 (pg. 2021 - 2024 ) Google Scholar Crossref Search ADS WorldCat 7 Stevie F A , Shane T C , Kahora P M , Hull R , Bahnck D , Kannan V C , David E . Applications of focused ion beams in microelectronics production, design and development , Surf. Interface Anal. , 1995 , vol. 23 (pg. 61 - 68 ) Google Scholar Crossref Search ADS WorldCat 8 Giannuzzi L A , Drown J L , Brown S R , Irwin R B , Stevie F A . Focused ion beam milling and micromanipulation lift-out for site specific cross-section TEM specimen , Preparation. Mater. Res. Soc. Symp. Proc. , 1997 , vol. 480 (pg. 19 - 27 ) Google Scholar Crossref Search ADS WorldCat 9 Giannuzzi L A , Drown J L , Brown S R , Irwin R B , Stevie F A . Applications of the FIB lift-out technique for TEM specimen preparation , Microsc. Res. Tech. , 1998 , vol. 41 (pg. 285 - 290 ) Google Scholar Crossref Search ADS PubMed WorldCat 10 Giannuzzi L A , Stevie F A . A review of focused ion beam milling techniques for TEM specimen preparation , Micron , 1999 , vol. 30 (pg. 197 - 204 ) Google Scholar Crossref Search ADS WorldCat 11 Stevie F A , Vartuli C B , Giannuzzi L A , Shofner T L , Brown S R , Rossie B , Hillion F , Millis R H , Antoneel M , Irwin R B , Purcell B M . Application of focused ion beam lift-out specimen preparation to TEM, SEM, STEM, AES and SIMS analysis , Surf. Interface Anal. , 2001 , vol. 31 (pg. 345 - 351 ) Google Scholar Crossref Search ADS WorldCat 12 Ishitani T , Umemura K , Ohnishi T , Yaguchi T . Improvements in performance of focused ion beam cross-sectioning: aspects of ion-sample interaction , J. Electron Microsc. , 2004 , vol. 53 (pg. 443 - 449 ) Google Scholar Crossref Search ADS WorldCat 13 Kamino T , Yaguchi T , Kuroda Y , Ohnishi T , Ishitani T , Miyahara Y , Horita Z . Evaluation of TEM samples of an Mg-Al alloy prepared using FIB milling at the operating voltages of 10 kV and 40 kV , J. Electron Microsc. , 2004 , vol. 53 (pg. 459 - 463 ) Google Scholar Crossref Search ADS WorldCat 14 Langrod R M , Clinton C . In situ lift-out using a FIB-SEM system , Micron , 2004 , vol. 35 (pg. 607 - 611 ) Google Scholar Crossref Search ADS PubMed WorldCat 15 Giannuzzi L A , Stevie F A . , Introduction to Focused Ion Beams , 2005 New York Springer Google Scholar Google Preview OpenURL Placeholder Text WorldCat COPAC 16 Prenitzer B I , Giannuzzi L A , Newman K , Brown S R , Irwin R B , Shofner T L , Stevie F A . Transmission electron microscope specimen preparation of Zn powders using the focused ion beam lift-out technique , Metall. Mater. Trans. A , 1998 , vol. 29 (pg. 2399 - 2406 ) Google Scholar Crossref Search ADS WorldCat 17 Lomness J K , Giannuzzi L A , Hampton M D . Site-specific transmission electron microscope characterization of micrometer-sized particles using the focused ion beam lift-out technique , Microsc. Microanal. , 2001 , vol. 7 (pg. 418 - 423 ) Google Scholar Crossref Search ADS PubMed WorldCat 18 Larson D J , Foord D T , Petford-Long A K , Anthony T C , Rozdilsky I M , Cerezo A , Smith G W D . Focused ion-beam milling for field-ion specimen preparation:: preliminary investigations , Ultramicroscopy , 1998 , vol. 75 (pg. 147 - 159 ) Google Scholar Crossref Search ADS WorldCat 19 Larson D J , Foord D T , Petford-Long A K , Liew H , Blamire M G , Cerezo A , Smith G W D . Field-ion specimen preparation using focused ion-beam milling , Ultramicroscopy , 1999 , vol. 79 (pg. 287 - 293 ) Google Scholar Crossref Search ADS WorldCat 20 Larson D J , Foord D T , Petford-Long A K , Cerezo A , Smith G W D . Focused ion-beam specimen preparation for atom probe field-ion microscopy characterization of multilayer film structures , Nanotechnology , 1999 , vol. 10 (pg. 45 - 50 ) Google Scholar Crossref Search ADS WorldCat 21 Larson D J , Wisman B D , Villieux R J , Martens R L , Gribb T T , Erskine H F , Kelly T F , Tabat N . Advances in atom probe specimen fabrication from planar multilayer thin film structures , Microsc. Microanal. , 2001 , vol. 7 (pg. 24 - 31 ) Google Scholar PubMed OpenURL Placeholder Text WorldCat 22 Thompson G B , Miller M K , Fraser H L . Some aspects of atom probe specimen preparation and analysis of thin film materials , Ultramicroscopy , 2004 , vol. 100 (pg. 25 - 34 ) Google Scholar Crossref Search ADS PubMed WorldCat 23 Miller M K , Russell K F , Thompson G B . Strategies for fabricating atom probe specimens with a dual beam FIB , Ultramicroscopy , 2005 , vol. 102 (pg. 287 - 298 ) Google Scholar Crossref Search ADS PubMed WorldCat 24 Blavette D , Deconihout B , Bostel A , Sarrau J , Bouet M , Menand A . The tomographic atom probe: a quantitative three-dimensional nanoanalytical instrument on an atomic scale , Rev. Sci. Instr. , 1993 , vol. 64 (pg. 2911 - 2919 ) Google Scholar Crossref Search ADS WorldCat 25 Yamaguchi H , Shimase A , Haraaichi S , Miyauchi T . Characteristics of silicon removal by fine gallium ion beam , J. Vac. Sci. Technol. B , 1985 , vol. 3 (pg. 71 - 74 ) Google Scholar Crossref Search ADS WorldCat 26 Ishitani T , Tsuboi H , Yaguchi T , Koike H . Transmission electron microscope sample preparation using a focused ion beam , J. Electron. Microsc. , 1994 , vol. 43 (pg. 322 - 326 ) OpenURL Placeholder Text WorldCat 27 Miller M K , Cerezo A , Hetherington M G , Smith G D W . , Atom Probe Field Ion Microscope , 1996 Clarendon Press, Oxford Google Scholar Google Preview OpenURL Placeholder Text WorldCat COPAC © The Author 2007. Published by Oxford University Press on behalf of Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oxfordjournals.org Oxford University Press TI - Transmission electron microscopy and atom probe specimen preparation from mechanically alloyed powder using the focused ion-beam lift-out technique JF - Journal of Electron Microscopy DO - 10.1093/jmicro/dfm003 DA - 2007-04-01 UR - https://www.deepdyve.com/lp/oxford-university-press/transmission-electron-microscopy-and-atom-probe-specimen-preparation-INo18F1hkX SP - 43 EP - 49 VL - 56 IS - 2 DP - DeepDyve ER -