TY - JOUR AU - , AB - Table of contents Introduction    287 The radiation burden due to cardiovascular imaging in   Europe    287 Radiation risk    287 State-of-the-art technologies and their impact on radiation  dose    288 New gamma camera detectors and software dedicated to   cardiac imaging    288 Positron emission tomography systems for cardiac imaging    288 Cardiac computed tomography    290 Changed protocols, which have impact on dosimetry and  patients    290 Single photon emission computed tomography protocols and tracers    290 Positron emission tomography protocols and tracers    292 Computed tomography protocols    292 Fusion computed tomography/single photon emission computed tomography–computed tomography/positron emission tomography imaging    293 Appropriate clinical use of non-invasive cardiac imaging for  reducing global radiation exposure    293 Impact on costs    294 Conclusions    294 Introduction The radiation burden due to cardiovascular imaging in Europe Cardiovascular diseases (CVDs) are the leading cause of death in Europe (5 million deaths per year) at a cost of €196 billion in 2009.1 Imaging techniques such as computed tomography (CT), single photon emission computed tomography (SPECT), and positron emission tomography (PET) play an increasingly important role in the diagnosis of CVD. Regarding myocardial perfusion imaging, scan volume has grown rapidly worldwide over the past two decades to 15–20 million procedures annually and diffusion of technology and expertise has led to its continued adoption across the developing world.2 However, there are concerns regarding the radiation burden associated with these diagnostic modalities. During the past 10 years, numerous technologies and data acquisition protocols for low-dose imaging have become available. The implementation of these technologies is always a balance between the long-term risk associated with exposure to ionizing radiation and the short-term risk related to impaired diagnostic accuracy. Furthermore, an important aspect to keep the dose as low as possible is to choose the most appropriate test for an individual patient using the correct acquisition protocol. From a clinical point of view, this implies to select the diagnostic test that is most likely to influence and direct patient care to improve outcome. From a technical point of view, this implies knowledge on differences between protocols and applying the protocol that results in the highest image quality with the lowest radiation exposure.3 Dose reduction is a multidisciplinary effort. For this reason, this article provides a consensus of three professional associations in the field of cardiac imaging—the European Association of Cardiovascular Imaging (EACVI), the Cardiovascular Committee of European Association of Nuclear Medicine (EANM), and the European Society of Cardiovascular Radiology (ESCR)—focusing on the balance between radiation dose and diagnostic accuracy, in agreement with the European guidelines endorsed by the involved associations. Radiation risk When considering the clinical indication for diagnostic procedures that use radiation, it is important to balance the short- and mid-term risks of the diseases remaining undetected and untreated against the long-term risk associated with radiation exposure.4 While ionizing radiation applied in the context of novel imaging technologies enables anatomical, functional, and molecular characterization of the whole heart with high accuracy, it poses a potential health risk because it may damage living tissues by changing cell structure and altering DNA. Sievert (Sv) is the unit of effective radiation dose in the International System of Units. One milliSv (mSv) corresponds to 10 J of energy of radiation transferred to 1 g of living tissue. The potential damage depends on not only the amount of absorbed energy and the different types of radiation but also the susceptibility of the tissue exposed to radiation. It has been shown that high-dose radiation exposure causes adverse health effects including an increased risk of cancer induction. Much of our knowledge about the risks from high-dose radiation is based on studies of survivors of the atomic bombs at Hiroshima and Nagasaki, as well as on the experiments with fruit flies performed by Hermann Muller, which built the basis for the linear non-threshold (LNT) model.5 The LNT model states that any radiation dose—no matter how small—may cause cancer. The LNT model currently still serves as the basis for international recommendations for radiation protection. This seems reasonable, despite some uncertainties about the accurate estimation of radiation-induced cancer risk. These uncertainties arise from the fact that the calculations are mainly based on data extrapolated from very high-dose exposure and only consider radiation dose while completely neglecting dose rate.6 Following the as low as reasonably achievable (ALARA) principle, contemporary cardiovascular examinations need to be performed with a radiation dose as low as possible. Recent literature indicates a median radiation exposure of 2–8 mSv for a nuclear myocardial perfusion scintigraphy (MPS),2 2–5 mSv for a cardiac PET,7 and 0.5–7 mSv for a coronary CT angiography (CCTA) scan.8 Moreover, in the setting of exclusion of clinically relevant coronary artery disease, the latest technologies in nuclear perfusion imaging and CT angiography enable examinations of <1 mSv.9,10 Estimation of risk from low-dose radiation exposure remains exceptionally difficult, but the risks are most likely small. Prospective trials focusing on adverse events associated with radiation exposure related to diagnostic procedures are difficult to perform. Randomized prospective data will probably hardly ever be available. A very recent study by Leuraud et al.11 followed over 300 000 radiation-monitored workers up for a total of 8.22 million person-years hinted a potential positive association between protracted low-dose radiation exposure and leukaemia, thus lending support to the concept of a linear dose response at low doses. The results from the ongoing studies, such as the Epi-CT study,12 which is currently recruiting over one million children or young adults who had CT scans in nine European countries with the aim of evaluating the radiation-related risk of cancer, may provide more solid evidence. State-of-the-art technologies and their impact on radiation dose In the last 15 years, a fast technological evolution of scanners, hardware as well as software for image acquisition and reconstruction, has allowed a dramatic improvement of efficiency and quality of cardiac imaging resulting in progressive reduction of radiation doses to the patient2,7,8 which are becoming comparable to natural radiation exposure.13 This fast technological evolution may cause an imbalance between the natural life cycle of technological equipment and the need for updating to the state-of-the-art technology. We will summarize in the subsequent paragraphs the major evolutions in nuclear cardiology and cardiac CT technology, which have an impact on radiation dose reduction (Figures1 and 2). Figure 1 View largeDownload slide Bar graph illustrating the average effective radiation doses of cardiac CT applying the various radiation dose reducing algorithms. Adapted from reference.14 Figure 1 View largeDownload slide Bar graph illustrating the average effective radiation doses of cardiac CT applying the various radiation dose reducing algorithms. Adapted from reference.14 Figure 2 View largeDownload slide Recommended radiotracer doses for MPI conventional scanners (white bar) and for scanners with new softwares and/or hardwares (grey bar). Full-dose PET radiotracer is used for 2D imaging and half-dose for 3D imaging; typically, equal dose of radiotracer is administered for rest and for stress PET MPI. Estimated dose is effective dose multiplied by administered activity. Dose is calculated for rest and stress scans separately, considering a single day examination. Adapted from reference.15 Figure 2 View largeDownload slide Recommended radiotracer doses for MPI conventional scanners (white bar) and for scanners with new softwares and/or hardwares (grey bar). Full-dose PET radiotracer is used for 2D imaging and half-dose for 3D imaging; typically, equal dose of radiotracer is administered for rest and for stress PET MPI. Estimated dose is effective dose multiplied by administered activity. Dose is calculated for rest and stress scans separately, considering a single day examination. Adapted from reference.15 New gamma camera detectors and software dedicated to cardiac imaging A growing number of nuclear medicine departments in Europe are now using a new generation of gamma cameras for cardiac imaging. In these so-called ‘CZT cameras’, the conventional sodium/iodine (Na/I) crystal used for the detection of gamma rays has been replaced by a cadmium–zinc–telluride (CZT) crystal. This crystal transforms directly the signal induced by gamma rays into electric impulses without the need for photodetectors. Manufacturers have taken advantage of these much thinner and more flexible CZT detectors to design the gamma cameras dedicated to cardiac imaging offering a larger surface for signal detection while focused on the heart region.16,17 The CZT gamma cameras provide a four- to seven-fold higher system sensitivity compared with Na/I-based cameras.18 This increase in signal detection efficiency has translated into a significant decrease in the dose of radiotracer required for cardiac scintigraphy. In turn, this has resulted to lower radiation exposure of patients and partly in shorter duration of acquisitions with preserved or even improved image quality and increase in the detection of coronary artery disease19 (Figure 3). Figure 3 View largeDownload slide A 60-year-old gentleman with typical angina. A single-day stress–rest low-dose protocol with 99mTc-tetrofosmin was performed, injecting 130 MBq at peak of exercise stress test and 390 MBq at rest. Stress and rest images were acquired for 6 and 5 min, respectively. CZT images reveal the presence of a reversible perfusion defect involving the inferoseptal wall, the inferior wall, the distal portion of the anteroseptal wall, and the apex. Figure 3 View largeDownload slide A 60-year-old gentleman with typical angina. A single-day stress–rest low-dose protocol with 99mTc-tetrofosmin was performed, injecting 130 MBq at peak of exercise stress test and 390 MBq at rest. Stress and rest images were acquired for 6 and 5 min, respectively. CZT images reveal the presence of a reversible perfusion defect involving the inferoseptal wall, the inferior wall, the distal portion of the anteroseptal wall, and the apex. Figure 4 View largeDownload slide Ultralow-dose coronary CTA performed in a 67-year-old female (BMI 20) with a 320-row multidetector CT scanner, using a single heartbeat acquisition technique. By combining an 80-kVp tube voltage with third-generation iterative reconstructions, a sub-mSv radiation dose was obtained (0.7 mSv) with a high diagnostic quality of the examination. Volume rendering (A) and curved planar reconstruction (B) images show the presence of a high-risk, eccentric, soft tissue lesion in the proximal right coronary artery causing a high-grade stenosis. Figure 4 View largeDownload slide Ultralow-dose coronary CTA performed in a 67-year-old female (BMI 20) with a 320-row multidetector CT scanner, using a single heartbeat acquisition technique. By combining an 80-kVp tube voltage with third-generation iterative reconstructions, a sub-mSv radiation dose was obtained (0.7 mSv) with a high diagnostic quality of the examination. Volume rendering (A) and curved planar reconstruction (B) images show the presence of a high-risk, eccentric, soft tissue lesion in the proximal right coronary artery causing a high-grade stenosis. Another significant evolution has been provided by new reconstruction algorithms. Novel iterative reconstruction methods with resolution recovery and noise reduction provide higher image contrast (with sharper defects and borders) and significantly improve image quality, particularly for low-count imaging studies from half- and quarter-dose radiotracer protocols.20 The value of the novel software is that existing scanners can be upgraded with advanced software to reduce radiation dose, a much smaller capital investment than buying a new scanner. Positron emission tomography systems for cardiac imaging Thanks to the development of more efficient crystals and electronics, cardiac PET imaging has shifted from a 2D detection mode to a 3D detection mode. Acquisition of PET images in a 3D mode increases the efficiency of signal detection by a factor of 2 and therefore requires, for similar image quality, the injection of only half of the dose of radiotracer formerly required in 2D mode.21,22 PET images require correction for tissue attenuation, which is currently provided by using maps derived from low-dose CT acquisitions. This low-dose CT-related radiation exposure adds up to that from PET. Thus, PET–CT examination will most likely benefit from current progresses in CT image reconstruction to reach lower levels of radiation exposure. This is even more important in hybrid cardiac PET/CT imaging that is used to combine PET and coronary CT angiography information on myocardial function and coronary anatomy, which will benefit even more from CT dose-saving protocols.23 The emerging digital PET detector technology based on silicon photomultipliers will allow for a further substantial reduction of injected dose and therefore decrease radiation exposure. Recently, a new generation of scanners has entered the clinical arena, integrating a magnetic resonance (MR) with a PET device into a hybrid PET/MR scanner.24,25 The preliminary results show that attenuation maps can be obtained from MR, avoiding the need for CT attenuation maps, therefore reducing the ionizing radiation to the patient.26 Cardiac computed tomography State-of-the-art cardiac CT scanners are equipped with 64 or more detector rows. Several technological advances can and should be used to acquire cardiac CT data sets at low radiation doses. Among them, fast scanner rotation with high temporal resolution has been important, as it permits prospectively electrocardiographically (ECG)-triggered image acquisition. In fact, it has been the introduction of prospective ECG triggering,27 which has paved the way for low radiation dose scanning in daily practice. Although this technique has less flexibility regarding the cardiac phase in which images are reconstructed, when compared with helical or spiral acquisition protocols with retrospective ECG gating, it results in substantially lower dose. Prospectively ECG-triggered high-pitch spiral acquisition protocols can further reduce the dose.28 All these lower dose acquisition protocols require lowering of the heart rate.29,30 The fact that modern X-ray tubes generate higher tube currents at the same potentials can also be used to reduce patient radiation exposure: low tube potentials—such as 70 or 80 kV—substantially reduce dose compared with the standard use of 100 or 120 kV, whereas high tube currents compensate for increased image noise.31 Dedicated roentgen tube filters can further reduce dose by effective shielding and modification of the X-ray spectrum. Various types of tube current modulation, to continuously adjust the tube output depending on the type and amount of tissue to be penetrated, can further reduce dose. Finally, iterative reconstruction algorithms, which improve image quality compared with the filtered back-projection techniques, allow for cardiac imaging at lower radiation exposure (Figure 4).32–34 A brief description of the main metrics used for characterization of CT radiation dose is depicted in Table1. Table 1 Description of the main metrics used for characterization of CT radiation dose Computed tomography dose index (CTDI)  Area under the radiation dose profile for a single rotation and fixed table position along the axial direction of the scanner divided by the total number of detectors for slice thickness and is expressed in coulomb/kg  CTDI100  Integrated radiation dose from acquiring a single scan over a length of 100 m  CTDIw  Average radiation dose to a cross-section of a patient’s body determined with the equation CTDIw=2/3CTDI100 at periphery+1/3CTDI100 at centre  CTDIvol  Average radiation dose over the volume scanned determined by the equation CTDIvol=CTDIw/pitch, where pitch is defined as table movement expressed in millimetres for each 360° gantry rotation, divided by the product of the number of slices and slice width. It is measured in milligray  Dose length product (DLP)  Integrated radiation dose for a complete CT examination measured in milligray×centimetres and calculated by the formula DLP=CTDIvol×length irradiated  Effective dose (ED)  Measured as the product between DLP and k, the region-specific conversion factor  Computed tomography dose index (CTDI)  Area under the radiation dose profile for a single rotation and fixed table position along the axial direction of the scanner divided by the total number of detectors for slice thickness and is expressed in coulomb/kg  CTDI100  Integrated radiation dose from acquiring a single scan over a length of 100 m  CTDIw  Average radiation dose to a cross-section of a patient’s body determined with the equation CTDIw=2/3CTDI100 at periphery+1/3CTDI100 at centre  CTDIvol  Average radiation dose over the volume scanned determined by the equation CTDIvol=CTDIw/pitch, where pitch is defined as table movement expressed in millimetres for each 360° gantry rotation, divided by the product of the number of slices and slice width. It is measured in milligray  Dose length product (DLP)  Integrated radiation dose for a complete CT examination measured in milligray×centimetres and calculated by the formula DLP=CTDIvol×length irradiated  Effective dose (ED)  Measured as the product between DLP and k, the region-specific conversion factor  Changed protocols, which have impact on dosimetry and patients Appropriate selection of radiotracer and acquisition protocols is critical in reducing patient radiation dose. All these variables must be considered while keeping in mind that diagnostic accuracy of the imaging test should be maintained (Table 2). As a good clinical practice, the overall radiation dose to the patient resulting from the given imaging procedure should be clearly indicated in the clinical report as recommended by current international procedures.3 Table 2 Practical ways to reduce radiation exposure Before the test  Consider implementing new imaging technologies allowing for radiation exposure  Select the optimal test for the individual patient and situation, guided by clinical guidelines and appropriateness criteria  Check for recently performed cardiac evaluations to avoid duplicate testing  If the clinical question is not clear or the test ordered is not the most appropriate test, discuss with the referring physician (consider a multidisciplinary approach)  Plan a personalized imaging protocol according to age, weight, and estimated prevalence of CAD  Avoid repeating examinations as a routine for unselected patients  At the time of the test  Myocardial scintigraphy: check the possibility to perform stress-only acquisition  After the test  (These recommendations do not reduce radiation exposure, but make others aware for potential future radiation exposure)  Report dose of radiotracers and total radiation exposure  Provide easy access to imaging and reports  Monitor trends in radiation exposure at your laboratory and compare with other laboratories  Before the test  Consider implementing new imaging technologies allowing for radiation exposure  Select the optimal test for the individual patient and situation, guided by clinical guidelines and appropriateness criteria  Check for recently performed cardiac evaluations to avoid duplicate testing  If the clinical question is not clear or the test ordered is not the most appropriate test, discuss with the referring physician (consider a multidisciplinary approach)  Plan a personalized imaging protocol according to age, weight, and estimated prevalence of CAD  Avoid repeating examinations as a routine for unselected patients  At the time of the test  Myocardial scintigraphy: check the possibility to perform stress-only acquisition  After the test  (These recommendations do not reduce radiation exposure, but make others aware for potential future radiation exposure)  Report dose of radiotracers and total radiation exposure  Provide easy access to imaging and reports  Monitor trends in radiation exposure at your laboratory and compare with other laboratories  Single photon emission computed tomography protocols and tracers Currently, it is not possible to issue precise recommendations regarding the doses of radiotracers for SPECT myocardial perfusion imaging (MPI) due to the lack of strong evidence linking a better performance of the test to specific injected doses. The dose of radiotracer to be administered is a compromise between image quality and radiation exposure and depends on patient characteristics (e.g. body weight), choice of radiopharmaceutical (99mTc compounds or 201Tl chloride),35 acquisition protocol (1 day or 2 days protocols, imaging time, pixel size, and gated acquisition), and the type of equipment (multiple head scintillation camera or a camera based on CZT detectors). For example, a weight- or body mass index (BMI)-based adjusted SPECT radiotracer dose may be better than a fixed dose to balance low radiation (58% radiation dose reduction) with optimal image quality.36 99mTc agents are to be preferred over 201Tl because of their shorter half-life, significantly lower effective dose, and superior image quality. Based on the current models for the calculation of absorbed effective doses,37 for 99mTc-labelled tracers, the effective dose for a full stress–rest protocol with 1000 MBq is approximately of 6–7 mSv.6 For a stress–rest protocol using 111 MBq of 201Tl (74 MBq for stress and 37 MBq at rest), the effective dose (∼11 mSv) is increased of almost a factor of 2. Stress-first enabling stress-only MPI using 99mTc tracers can significantly reduce the radiation dose compared with standard dose rest–stress MPI protocols. If the stress MPI results are normal, the rest scan can be omitted, with significant savings in cost, time, and radiotracer exposure to the patient (35% dose reduction) and to the laboratory staff (40% dose reduction).38 Prone imaging can be used as an alternative strategy for troubleshooting attenuation-dependent inferior wall perfusion defects. The attenuation correction CT scan results in an additional dose of 0.5–1.0 mSv. However, attenuation correction using radionuclide or CT-based transmission scans may reduce the need for rest MPI imaging in a significant percentage of patients, thus limiting the overall radiation dose.39,40 In patients with increasing body weight, such as in obesity or body habitus in women, the image quality may be limited, reducing the possibility to perform routinely stress-only protocol. The technology of the gamma cameras is another variable that may help reducing the radiation dose. Low radiotracer dose protocols (half-dose or less than half-dose) using novel scanners, collimators, or software are increasingly utilized. Camera systems based on new technologies (e.g. CZT cameras) have improved count sensitivity for the detection of gamma rays. The increased sensitivity enables shorter image acquisition duration.12,41–44 Nevertheless, in light of the ALARA principle, this improved sensitivity should preferentially be used to reduce the amount of injected dose preserving the image quality.45 Effective doses below 2 mSv can be achieved by administering low-dose 99mTc tracers (lower than 148 MBq) and combining stress-only protocols with new scanner technologies. Taken together, there are plenty of opportunities to reduce patient radiation burden without major impact on image quality and thereby maintaining diagnostic accuracy.38,41–43,45 Efforts should be directed towards reducing radiation exposure by taking advantage of the recent development in SPECT technology. The key points include main steps to set-up a nuclear cardiology protocol to minimize the radiation exposure. Best practice  Dose (mSv)  Prefer radiotracers with low radiation exposure 99mTc (stress/rest protocol, 4 mCi/12 mCi, respectively)  2–8  Check the possibility to perform stress-only acquisition (4 mCi)  ≤2  Use weight-based radiotracer doses    Appropriate use of attenuation correction  0.5–1  Avoid 201Tl (stress/rest protocol)  >8  Avoid dual isotope imaging  >8  Best practice  Dose (mSv)  Prefer radiotracers with low radiation exposure 99mTc (stress/rest protocol, 4 mCi/12 mCi, respectively)  2–8  Check the possibility to perform stress-only acquisition (4 mCi)  ≤2  Use weight-based radiotracer doses    Appropriate use of attenuation correction  0.5–1  Avoid 201Tl (stress/rest protocol)  >8  Avoid dual isotope imaging  >8  Positron emission tomography protocols and tracers Estimated whole-body effective radiation dose is directly related to the half-life of the radiotracer and dose of radiotracer administered. In general, PET myocardial perfusion tracers have the advantage of their short to very short half-lives. For the evaluation of myocardial perfusion 82Rb and 13N-ammonia, the most commonly utilized tracers for clinical imaging provide high image quality and low radiation exposure. Positron emission tomography protocols allow for quantitation of absolute myocardial blood flow (MBF) in mL/min/g, and MBF reserve providing additional relevant information in different patient populations46–50 and for selected clinical conditions (balanced myocardial ischaemia and microvascular disease).17 O-water is the gold standard radiotracer for the measurement of MBF with PET and provides parametric quantitative representation of MBF with low radiation exposure. A complete stress–rest study can be performed with a total radiation exposure of 2–4 mSv for 13N-ammonia, 3–5 mSv for 82Rb and 1–2 mSv for 15O-water. New 18F-labelled PET radiotracers for MPI are currently under evaluation and can be used with exercise stress testing because of their longer half-life and longer retention times.51 The use of 13N-ammonia and 15O-water requires an on-site cyclotron for the synthesis of radiotracer. 82Rb can be produced in a generator, which is relatively cheap even if the monthly costs of precursor are high requiring high patient throughput to be cost-effective. As for SPECT, a weight- or BMI-based adjusted PET radiotracer dose is recommended to reduce radiation dose and preserve optimal image quality. Moreover, as recently demonstrated by Danad et al.,52 further reduction of radiation exposure can be achieved by a stress-only protocol. The use of a quantitative cut-off for absolute hyperaemic myocardial blood flow may provide even a superior accuracy for diagnosing haemodynamically significant coronary artery disease (CAD) when compared with quantification of flow reserve that requires rest/stress protocol. For evaluation of myocardial viability, the typical protocol includes a PET perfusion study and a PET metabolic study using 18F-fluorodeoxyglucose (18 F-FDG). A strategy to reduce radiation exposure is the use of 18F-FDG without PET MPI, as preserved uptake of FDG can be regarded as a sign of viability.53 A typical 18 F-FDG cardiac study results in ∼3–5 mSv. In PET/CT scanners, accurate attenuation correction of cardiac PET image is provided by CT, with a small increase in radiation dose. Using a single CT scan for attenuation correction of multiple PET acquisitions can further reduce the global dose.54 Recent developments in PET technology (e.g. 3D detection mode and silicon photomultipliers) may allow to further reduce the injected dose and hence the radiation exposure. The key points include main steps to set-up a cardiac PET protocol to minimize the radiation exposure. Best practice  Dose  Check the possibility to perform stress-only acquisition (99mTc tracers, 4 mCi)  50% dose reduction  Use weight-based radiotracer doses    Appropriate use of attenuation correction  0 5–1 mSv  Avoid dual isotope imaging of viability when possible (FDG only, 10 mCi)  3–5 mSv  Know the radiation dose associated with each radiotracer in a typical perfusion study    13N-ammonia (10 mCi) (stress or rest)  2 mSv  15O-water (24 mCi) (stress or rest)  1.5 mSv  82Rubidium (20 mCi) (stress or rest)  2.5 mSv  Best practice  Dose  Check the possibility to perform stress-only acquisition (99mTc tracers, 4 mCi)  50% dose reduction  Use weight-based radiotracer doses    Appropriate use of attenuation correction  0 5–1 mSv  Avoid dual isotope imaging of viability when possible (FDG only, 10 mCi)  3–5 mSv  Know the radiation dose associated with each radiotracer in a typical perfusion study    13N-ammonia (10 mCi) (stress or rest)  2 mSv  15O-water (24 mCi) (stress or rest)  1.5 mSv  82Rubidium (20 mCi) (stress or rest)  2.5 mSv  Computed tomography protocols Until approximately 2006, most coronary CT angiograms were acquired using a retrospectively ECG-gated spiral scan mode. The principle of this scan mode is the continuous table movement and data acquisition over several cardiac cycles, after which cardiac phase-consistent projections are combined using a recorded rhythm trace to reconstruct the images. For image reconstruction, the desired phase of the cardiac cycle is specified and only X-ray data acquired during this phase is used for image reconstruction while the remaining data are often discarded. If desired, multiple reconstructions at various time points of the cardiac cycle can be obtained. This allows for selecting the phase with least motion artefacts and, within limits, permits to correct for arrhythmias and other artefacts. The major drawback of this protocol is the high radiation exposure caused by temporal and spatial oversampling. Modifications have been designed to reduce overall radiation exposure. ECG-triggered X-ray tube current modulation is an algorithm that can reduce the tube output during the phases that are less likely to be used for the reconstruction. This approach is effective in terms of radiation dose reduction and should be considered as a standard practice with retrospectively gated spiral CT protocols. In patients with stable and low heart rates (usually below 65 b.p.m.), prospectively ECG-triggered axial scan protocols, also known as ‘sequential’ or ‘step-and-shoot’ protocols, have largely replaced spiral protocols. The advantage of the axial scan protocol is that exposure only occurs during the phase that is intended for reconstruction, minimizing the overall radiation exposure. Also the z-axis oversampling is less using axial scan protocols. The drawback is that it relies on a regular and relatively low heart rate. Depending on the system, no alternative cardiac phases may be available in the case of suboptimal image quality. More recent systems operate axial scan protocols that allow for prolonged sampling and reconstruction of additional phases (also known as ‘padding’) and are also equipped with arrhythmia detection and handling algorithms. In the event of an irregular heartbeat, the acquisition at a given location is interrupted and/or repeated. An additional strategy to reduce the radiation exposure is based on reduction of scan time. Wide detector array scanners (256–320 rows) and second- and third-generation dual-source CT scanners with high-pitch spiral scan protocols allow for complete coverage of the heart in a single gantry rotation. Single-beat acquisition avoids ‘step’ or ‘misalignment’ artefacts seen on image acquisition during multiple heartbeats and is generally associated with a lower radiation exposure. Radiation exposure is very low due to the lack of oversampling. The prospectively ECG-triggered high-pitch spiral protocol on dual-source scanners results in substantially lower doses but requires a slow and regular heart rhythm.55,56 Absorbed doses from CT coronary angiography (CTCA) depend on the system and imaging protocol used and can be estimated between 2 and 5 mSv using commonly available single-source 64-slice CT scanners with a prospectively ECG-triggered step-and-shoot acquisition protocol.57,58 In suitable patients, the acquisition protocols allowed by the newest CT hardwares and softwares enable even lower absorbed doses <1 mSv.9,28 Finally, if the lowering of tube voltage is a very effective radiation dose-saving strategy in CCTA due to the correlation between effective dose and the square of tube voltage, this is not possible for calcium score. Indeed, the change of scan parameter can influence the CAC value, and therefore, in this setting, only tube current optimization can be performed. The key points include main steps to set-up a CT protocol to minimize the radiation exposure. Perform scan length optimization  Perform a topogram before the contrast-enhanced scan to minimize scan length and overall ED  Set-up tube voltage and tube current  Consider a trade-off between higher image noise and lower contrast resolution  For clinical practice: tube voltage of 100 and 120 kVp for patients with BMI <30 and >30 kg/m2, respectively  Choice of ECG triggering  High heart rate: retrospective ECG triggering with tube current modulation  Low heart rate: prospective ECG-triggering  Last-generation scanner: single-beat acquisition  Perform scan length optimization  Perform a topogram before the contrast-enhanced scan to minimize scan length and overall ED  Set-up tube voltage and tube current  Consider a trade-off between higher image noise and lower contrast resolution  For clinical practice: tube voltage of 100 and 120 kVp for patients with BMI <30 and >30 kg/m2, respectively  Choice of ECG triggering  High heart rate: retrospective ECG triggering with tube current modulation  Low heart rate: prospective ECG-triggering  Last-generation scanner: single-beat acquisition  Fusion computed tomography/single photon emission computed tomography–computed tomography/positron emission tomography imaging ‘Fusion’ or ‘hybrid’ imaging describes the integration of complementary imaging modalities to improve yield, accuracy, clinical, and prognostic impact of single imaging modalities. Early studies dating back nearly a decade have reported radiation doses from hybrid CT/SPECT imaging in the range of 15–25 mSv59 and in the range of 9–15 mSv for hybrid CT/PET imaging.23 Due to the added radiation exposure, sensible and careful patient selection for hybrid imaging procedures remains crucial. Even if large trials have yet to be conducted, it seems reasonable to address to hybrid imaging studies for those patients in whom perfusion defect allocation and assessment of the haemodynamic significance of individual lesions will play a determining role for further treatment and particularly for guiding revascularization procedures.60,61 A potential strategy to reduce the added radiation exposure is to perform sequential imaging studies, where CTCA is used as a gatekeeper for SPECT or PET imaging.62 As previously described, a number of extremely effective strategies and protocols are now available for reducing radiation exposure of both radionuclide imaging and CTCA. When all the aforementioned dose reduction strategies are exploited, full and comprehensive hybrid imaging studies may be obtained at a cumulative radiation dose as low as 4 mSv.63 At such doses, hybrid imaging can be considered in wider patient populations with a very acceptable safety profile. Appropriate clinical use of non-invasive cardiac imaging for reducing global radiation exposure Nuclear and CT imaging are included in the management flow charts of patients with different cardiovascular diseases providing unique or alternative information when compared with other imaging modalities. Current international guidelines and recommendations include nuclear cardiology techniques and cardiac CT as appropriate modalities for different clinical scenarios (see Supplementary material online, S1). Nevertheless, selection of functional cardiovascular imaging by nuclear modalities and anatomical imaging by CT depends on multiple factors including the clinical question, the age of the patient, the estimated pre-test probability of the disease, costs, availability and local expertise for each imaging technology, physician preferences, and patient convenience.64 Some of these factors determine the overall radiation exposure that the patient will receive and, following the most recent clinical guidelines from the European Society of Cardiology (ESC) can be favourably modified taking into account the ALARA principle. However, as underlined in a recent joint position document on three main different associations of the ESC: ‘All other considerations being equal, it is not recommended to perform tests involving ionizing radiation when the desired information can be obtained with a non-ionizing test with comparable accuracy. If you perform a test that utilizes ionizing radiation, choose the one with the lowest dose and be aware of the many factors modulating dose’.3 In the current ESC guidelines on stable CAD,64 stress echocardiography, stress MRI, and stress MPS have the same level of recommendation for diagnosis and are considered as equally valid alternatives and should be taken into account to reduce radiation exposure. However, it should also be considered that imaging tests may carry risks not only related with radiations such as those associated with stressors, contrast agents, or other energy sources. For example, the induction of DNA double-strand breaks has been described after exposure to non-ionizing radiation from cardiac MR scanning65,66 even if its impact on long-term risk is not clear and has not yet been sufficiently explored. The knowledge of all advantages and pitfalls for each imaging technique should be well known to select the best one for each patient. A brief description of the role of nuclear diagnostic imaging in several clinical scenarios, as indicated in the current ESC guidelines and recommendations, is summarized in Supplementary material online, S1.67–77 Impact on costs Total expenditures related to advanced imaging show an increasing trend in Europe, raising concerns among health care providers.78 As a consequence, evaluation of diagnostic tests is shifting to an assessment of their effect on clinical outcomes in relation to treatment and in particular cost-effectiveness rather than on their diagnostic accuracy alone. Although most of the publications using non-invasive testing indicate cost-effectiveness over strategies without non-invasive tests, the overall published data are conflicting, particularly regarding the question which non-invasive strategy is the most cost-effective. Moreover, the definition of effectiveness often includes diagnostic accuracy or downstream utilization of resources and rarely more relevant endpoints such as efficacy on clinical outcome. In addition, the definition of costs generally does not include those related with missed/over diagnosis or with the risks potentially associated with the procedure. There are no studies available on the cost-effectiveness of radiation dose reduction strategies. Due to the present uncertainty of the risks associated with low radiation doses, the results of long follow-up studies assessing the impact on health and related costs are essential. However, lower dosages of the specific and most often expensive radiopharmaceuticals will most likely result in lower costs even if this assumption is dependent on local and national differences. In contrast with nuclear cardiology procedures, it is more difficult to predict the effects on costs in relation to a reduction in radiation dose with CT-driven protocols. Conclusions The increasing awareness of procedure-associated radiation has triggered the introduction of novel imaging protocols, and the development of new imaging technologies aiming at lowering radiation dose with further optimization of image quality. The state-of-the-art nuclear cardiology and cardiac CT imaging require embracing best practices for appropriate patient selection, patient-centred imaging protocols, use of novel protocols for traditional scanners, and adoption of laboratory practices to reduce lifetime radiation exposure for patients and staff members. This strategy requires a close collaboration between the three main European Societies (EACVI, EANM, and ESCR) to disseminate and educate the different myocardial imaging professionals as well as the referring clinical cardiologists. Supplementary material Supplementary material is available at European Heart Journal online. Acknowledgements All the authors would like to thank Rozemarijn Vliegenthart for her substantial help in the revision of the manuscript. Conflict of interest: none declared. References 1 WHO. Cardiovascular Diseases (CVDs) . Fact sheet no. 317. Geneva, Switzerland: World Health Organization; 2015. 2 Einstein AJ, Pascual TN, Mercuri M, Karthikeyan G, Vitola JV, Mahmarian JJ, Better N, Bouyoucef SE, Hee-Seung Bom H, Lele V, Magboo VP, Alexánderson E, Allam AH, Al-Mallah MH, Flotats A, Jerome S, Kaufmann PA, Luxenburg O, Shaw LJ, Underwood SR, Rehani MM, Kashyap R, Paez D, Dondi M; INCAPS Investigators Group. Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS). Eur Heart J  2015; 36: 1689– 1696. Google Scholar CrossRef Search ADS PubMed  3 Picano E, Vañó E, Rehani MM, Cuocolo A, Mont L, Bodi V, Bar O, Maccia C, Pierard L, Sicari R, Plein S, Mahrholdt H, Lancellotti P, Knuuti J, Heidbuchel H, Di Mario C, Badano LP. The appropriate and justified use of medical radiation in cardiovascular imaging: a position document of the ESC Associations of Cardiovascular Imaging, Percutaneous Cardiovascular Interventions and Electrophysiology. Eur Heart J  2014; 35: 665– 672. Google Scholar CrossRef Search ADS PubMed  4 Knuuti J, Bengel F, Bax JJ, Kaufmann PA, Le Guludec D, Perrone Filardi P, Marcassa C, Ajmone Marsan N, Achenbach S, Kitsiou A, Flotats A, Eeckhout E, Minn H, Hesse B. Risks and benefits of cardiac imaging: an analysis of risks related to imaging for coronary artery disease. Eur Heart J  2014; 35: 633– 638. Google Scholar CrossRef Search ADS PubMed  5 Muller HJ. Nobel Prize Lecture. http://www.nobelprize.org/nobel_prizes/medicine/laureates/1946/muller-lecture.html (2 February 2016). 6 ICRP. Low-dose extrapolation of radiation-related cancer risk. ICRP Publication 99. Ann ICRP  2005; 35: 1– 140. 7 Lindner O, Pascual TN, Mercuri M, Acampa W, Burchert W, Flotats A, Kaufmann PA, Kitsiou A, Knuuti J, Underwood SR, Vitola JV, Mahmarian JJ, Karthikeyan G, Better N, Rehani MM, Kashyap R, Dondi M, Paez D, Einstein AJ; INCAPS Investigators Group. Nuclear cardiology practice and associated radiation doses in Europe: results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries. Eur J Nucl Med Mol Imaging  2016; 43: 718– 728. Google Scholar CrossRef Search ADS PubMed  8 Einstein AJ, Berman DS, Min JK, Hendel RC, Gerber TC, Carr JJ, Cerqueira MD, Cullom SJ, DeKemp R, Dickert NW, Dorbala S, Fazel R, Garcia EV, Gibbons RJ, Halliburton SS, Hausleiter J, Heller GV, Jerome S, Lesser JR, Raff GL, Tilkemeier P, Williams KA, Shaw LJ. Patient-centered imaging: shared decision making for cardiac imaging procedures with exposure to ionizing radiation. J Am Coll Cardiol  2014; 63: 1480– 1489. Google Scholar CrossRef Search ADS PubMed  9 Fuchs TA, Stehli J, Bull S, Dougoud S, Clerc OF, Herzog BA, Buechel RR, Gaemperli O, Kaufmann PA. Coronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination. Eur Heart J  2014; 35: 1131– 1136. Google Scholar CrossRef Search ADS PubMed  10 Einstein AJ, Blankstein R, Andrews H, Fish M, Padgett R, Hayes SW, Friedman JD, Qureshi M, Rakotoarivelo H, Slomka P, Nakazato R, Bokhari S, Di Carli M, Berman DS. Comparison of image quality, myocardial perfusion, and left ventricular function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: the MILLISIEVERT study. J Nucl Med  2014; 55: 1430– 1437. Google Scholar CrossRef Search ADS PubMed  11 Leuraud K, Richardson DB, Cardis E, Daniels RD, Gillies M, O’Hagan JA, Hamra GB, Haylock R, Laurier D, Moissonnier M, Schubauer-Berigan MK, Thierry-Chef I, Kesminiene A. Ionising radiation and risk of death from leukaemia and lymphoma in radiation-monitored workers (INWORKS): an international cohort study. Lancet Haematol  2015; 2: e276– e281. Google Scholar CrossRef Search ADS PubMed  12 Bosch de Basea M, Pearce MS, Kesminiene A, Bernier MO, Dabin J, Engels H, Hauptmann M, Krille L, Meulepas JM, Struelens L, Baatout S, Kaijser M, Maccia C, Jahnen A, Thierry-Chef I, Blettner M, Johansen C, Kjaerheim K, Nordenskjöld A, Olerud H, Salotti JA, Andersen TV, Vrijheid M, Cardis E. EPI-CT: design, challenges and epidemiological methods of an international study on cancer risk after paediatric and young adult CT. J Radiol Prot  2015; 35: 611– 628. Google Scholar CrossRef Search ADS PubMed  13 Shahbazi-Gahrouei D, Gholami M, Setayandeh S. A review on natural background radiation. Adv Biom Res  2013; 2: 65– 67. Google Scholar CrossRef Search ADS   14 Alkadhi H, Leschka S. Radiation dose of cardiac computed tomography—what has been achieved and what needs to be done. Eur Radiol  2011; 21: 505– 509. Google Scholar CrossRef Search ADS PubMed  15 Dorbala S, Blankstein R, Skali H, Park MA, Fantony J, Mauceri C, Semer J, Moore SC, Di Carli MF. Approaches to reducing radiation dose from radionuclide myocardial perfusion imaging. J Nucl Med  2015; 56: 592– 599. Google Scholar CrossRef Search ADS PubMed  16 Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S, Berman DS. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging  2008; 1: 156– 163. Google Scholar CrossRef Search ADS PubMed  17 Bocher M, Blevis IM, Tsukerman L, Shrem Y, Kovalski G, Volokh L. A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. Eur J Nucl Med Mol Imaging  2010; 37: 1887– 1902. Google Scholar CrossRef Search ADS PubMed  18 Imbert L, Poussier S, Franken PR, Songy B, Verger A, Morel O, Wolf D, Noel A, Karcher G, Marie PY. Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images. J Nucl Med  2012; 53: 1897– 1903. Google Scholar CrossRef Search ADS PubMed  19 Gimelli A, Bottai M, Giorgetti A, Genovesi D, Kusch A, Ripoli A, Marzullo P. Comparison between ultrafast and standard single-photon emission CT in patients with coronary artery disease: a pilot study. Circ Cardiovasc Imaging  2011; 4: 51– 58. Google Scholar CrossRef Search ADS PubMed  20 DePuey EG. Advances in SPECT camera software and hardware: currently available and new on the horizon. J Nucl Cardiol  2012; 19: 551– 581. Google Scholar CrossRef Search ADS PubMed  21 Schepis T, Gaemperli O, Treyer V, Valenta I, Burger C, Koepfli P, Namdar M, Adachi I, Alkadhi H, Kaufmann PA. Absolute quantification of myocardial blood flow with 13N-ammonia and 3-dimensional PET. J Nucl Med  2007; 48: 1783– 1789. Google Scholar CrossRef Search ADS PubMed  22 Knesaurek K, Machac J, Krynyckyi BR, Almeida OD. Comparison of 2-dimensional and 3-dimensional 82Rb myocardial perfusion PET imaging. J Nucl Med  2003; 44: 1350– 1356. Google Scholar PubMed  23 Flotats A, Knuuti J, Gutberlet M, Marcassa C, Bengel FM, Kaufmann PA, Rees MR, Hesse B; Cardiovascular Committee of the EANM, the ESCR and the ECNC. Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC). Eur J Nucl Med Mol Imaging  2011; 38: 201– 212. Google Scholar CrossRef Search ADS PubMed  24 Rischpler C, Nekolla SG, Dregely I, Schwaiger M. Hybrid PET/MR imaging of the heart: potential, initial experiences, and future prospects. J Nucl Med  2013; 54: 402– 415. Google Scholar CrossRef Search ADS PubMed  25 Kaufmann PA. Cardiac PET/MR: Big footprint-small step? J Nucl Cardiol  2015; 22: 225– 226. Google Scholar CrossRef Search ADS PubMed  26 Vontobel J, Liga R, Possner M, Clerc OF, Mikulicic F, Veit-Haibach P, Ter Voert EE, Fuchs TA, Stehli J, Pazhenkottil AP, Benz DC, Gräni C, Gaemperli O, Herzog B, Buechel RR, Kaufmann PA. MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction. Eur J Nucl Med Mol Imaging  2015; 42: 1574– 1580. Google Scholar CrossRef Search ADS PubMed  27 Husmann L, Valenta I, Gaemperli O, Adda O, Treyer V, Wyss CA, Veit-Haibach P, Tatsugami F, von Schulthess GK, Kaufmann PA. Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J  2008; 29: 191– 197. Google Scholar CrossRef Search ADS PubMed  28 Achenbach S, Marwan M, Ropers D, Schepis T, Pflederer T, Anders K, Kuettner A, Daniel WG, Uder M, Lell MM. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J  2010; 31: 340– 346. Google Scholar CrossRef Search ADS PubMed  29 Hausleiter J, Meyer TS, Martuscelli E, Spagnolo P, Yamamoto H, Carrascosa P, Anger T, Lehmkuhl L, Alkadhi H, Martinoff S, Hadamitzky M, Hein F, Bischoff B, Kuse M, Schömig A, Achenbach S. Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study. JACC Cardiovasc Imaging  2012; 5: 484– 493. Google Scholar CrossRef Search ADS PubMed  30 Deseive S, Pugliese F, Meave A, Alexanderson E, Martinoff S, Hadamitzky M, Massberg S, Hausleiter J. Image quality and radiation dose of a prospectively electrocardiography-triggered high-pitch data acquisition strategy for coronary CT angiography: the multicenter, randomized PROTECTION IV study. J Cardiovasc Comput Tomogr  2015; 9: 278– 285. Google Scholar CrossRef Search ADS PubMed  31 Hell MM, Bittner D, Schuhbaeck A, Muschiol G, Brand M, Lell M, Uder M, Achenbach S, Marwan M. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction. J Cardiovasc Comput Tomogr  2014; 8: 418– 425. Google Scholar CrossRef Search ADS PubMed  32 Yin WH, Lu B, Li N, Han L, Hou ZH, Wu RZ, Wu YJ, Niu HX, Jiang SL, Krazinski AW, Ebersberger U, Meinel FG, Schoepf UJ. Iterative reconstruction to preserve image quality and diagnostic accuracy at reduced radiation dose in coronary CT angiography: an intraindividual comparison. JACC Cardiovasc Imaging  2013; 6: 1239– 1249. Google Scholar CrossRef Search ADS PubMed  33 Deseive S, Chen MY, Korosoglou G, Leipsic J, Martuscelli E, Carrascosa P, Mirsadraee S, White C, Hadamitzky M, Martinoff S, Menges AL, Bischoff B, Massberg S, Hausleiter J. Prospective randomized trial on radiation dose estimates of CT angiography applying iterative image reconstruction: the PROTECTION V study. JACC Cardiovasc Imaging  2015; 8: 888– 896. Google Scholar CrossRef Search ADS PubMed  34 Benz DC, Gräni C, Hirt Moch B, Mikulicic F, Vontobel J, Fuchs TA, Stehli J, Clerc OF, Possner M, Pazhenkottil AP, Gaemperli O, Buechel RR, Kaufmann PA. Minimized Radiation and contrast agent exposure for coronary computed tomography angiography: first clinical experience on a latest generation 256-slice scanner. Acad Radiol  2016; 23: 1008– 1014. Google Scholar CrossRef Search ADS PubMed  35 Verberne HJ, Acampa W, Anagnostopoulos C, Ballinger J, Bengel F, De Bondt P, Buechel RR, Cuocolo A, van Eck-Smit BL, Flotats A, Hacker M, Hindorf C, Kaufmann PA, Lindner O, Ljungberg M, Lonsdale M, Manrique A, Minarik D, Scholte AJ, Slart RH, Trägårdh E, de Wit TC, Hesse B; European Association of Nuclear Medicine (EANM). EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging  2015; 42: 1929– 1940. Google Scholar CrossRef Search ADS PubMed  36 Marcassa C, Zoccarato O, Calza P, Campini R. Temporal evolution of administered activity in cardiac gated SPECT and patients’ effective dose: analysis of an historical series. Eur J Nucl Med Mol Imaging  2013; 40: 325– 330. Google Scholar CrossRef Search ADS PubMed  37 Andersson M, Johansson L, Minarik D, Leide-Svegborn S, Mattsson S. Effective dose to adult patients from 338 radiopharmaceuticals estimated using ICRP biokinetic data, ICRP/ICRU computational reference phantoms and ICRP 2007 tissue weighting factors. EJNMMI Phys  2014; 1: 9. Google Scholar CrossRef Search ADS PubMed  38 Duvall WL, Guma KA, Kamen J, Croft LB, Parides M, George T, Henzlova MJ. Reduction in occupational and patient radiation exposure from myocardial perfusion imaging: impact of stress-only imaging and high-efficiency SPECT camera technology. J Nucl Med  2013; 54: 1251– 1257. Google Scholar CrossRef Search ADS PubMed  39 Gibson PB, Demus D, Noto R, Hudson W, Johnson LL. Low event rate for stress only perfusion imaging in patients evaluated for chest pain. J Am Coll Cardiol  2002; 39: 999– 1004. Google Scholar CrossRef Search ADS PubMed  40 Shaw LJ, Mieres JH, Hendel RH, Boden WE, Gulati M, Veledar E, Hachamovitch R, Arrighi JA, Merz CN, Gibbons RJ, Wenger NK, Heller GV; WOMEN Trial Investigators. Comparative effectiveness of exercise electrocardiography with or without myocardial perfusion single photon emission computed tomography in women with suspected coronary artery disease: results from the What Is the Optimal Method for Ischemia Evaluation in Women (WOMEN) trial. Circulation  2011; 124: 1239– 1249. Google Scholar CrossRef Search ADS PubMed  41 Duvall WL, Croft LB, Ginsberg ES, Einstein AJ, Guma KA, George T, Henzlova MJ. Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera. J Nucl Cardio  2011; 18: 847– 857. Google Scholar CrossRef Search ADS   42 Herzog BA, Buechel RR, Katz R, Brueckner M, Husmann L, Burger IA, Wolfrum M, Nkoulou RN, Valenta I, Ghadri JR, Treyer V, Kaufmann PA. Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction. J Nucl Med  2010; 51: 46– 51. Google Scholar CrossRef Search ADS PubMed  43 Nkoulou R, Pazhenkottil AP, Kuest SM, Ghadri JR, Wolfrum M, Husmann L, Fiechter M, Buechel RR, Herzog BA, Koepfli P, Burger C, Gaemperli O, Kaufmann PA. Semiconductor detectors allow low-dose-low-dose 1-day SPECT myocardial perfusion imaging. J Nucl Med  2011; 52: 1204– 1209. Google Scholar CrossRef Search ADS PubMed  44 Oddstig J, Hedeer F, Jogi J, Carlsson M, Hindorf C, Engblom H. Reduced administered activity, reduced acquisition time, and preserved image quality for the new CZT camera. J Nucl Cardiol  2013; 20: 38– 44. Google Scholar CrossRef Search ADS PubMed  45 Acampa W, Buechel RR, Gimelli A. Low dose in nuclear cardiology: state of the art in the era of new cadmium-zinc-telluride cameras. Eur Heart J Cardiovasc Imaging  2016; 17: 591– 595. Google Scholar CrossRef Search ADS PubMed  46 Neglia D, Michelassi C, Trivieri MG, Sambuceti G, Giorgetti A, Pratali L, Gallopin M, Salvadori P, Sorace O, Carpeggiani C, Poddighe R, L’Abbate A, Parodi O. Prognostic role of myocardial blood flow impairment in idiopathic left ventricular dysfunction. Circulation  2002; 105: 186– 193. Google Scholar CrossRef Search ADS PubMed  47 Cecchi F, Olivotto I, Gistri R, Lorenzoni R, Chiriatti G, Camici PG. Coronary microvascular dysfunction and prognosis in hypertrophic cardiomyopathy. N Engl J Med  2003; 349: 1027– 1035. Google Scholar CrossRef Search ADS PubMed  48 Schindler TH, Schelbert HR, Quercioli A, Dilsizian V. Cardiac PET imaging for the detection and monitoring of coronary artery disease and microvascular health. JACC Cardiovasc Imaging  2010; 3: 623– 640. Google Scholar CrossRef Search ADS PubMed  49 Murthy VL, Naya M, Foster CR, Hainer J, Gaber M, Di Carli G, Blankstein R, Dorbala S, Sitek A, Pencina MJ, Di Carli MF. Improved cardiac risk assessment with noninvasive measures of coronary flow reserve. Circulation  2011; 124: 2215– 2224. Google Scholar CrossRef Search ADS PubMed  50 Murthy VL, Naya M, Foster CR, Gaber M, Hainer J, Klein J, Dorbala S, Blankstein R, Di Carli MF. Association between coronary vascular dysfunction and cardiac mortality in patients with and without diabetes mellitus. Circulation  2012; 126: 1858– 1868. Google Scholar CrossRef Search ADS PubMed  51 Berman DS, Maddahi J, Tamarappoo BK, Czernin J, Taillefer R, Udelson JE, Gibson CM, Devine M, Lazewatsky J, Bhat G, Washburn D. Phase II safety and clinical comparison with single-photon emission computed tomography myocardial perfusion imaging for detection of coronary artery disease: flurpiridaz F 18 positron emission tomography. J Am Coll Cardiol  2013; 61: 469– 477. Google Scholar CrossRef Search ADS PubMed  52 Danad I, Uusitalo V, Kero T, Saraste A, Raijmakers PG, Lammertsma AA, Heymans MW, Kajander SA, Pietilä M, James S, Sörensen J, Knaapen P, Knuuti J. Quantitative assessment of myocardial perfusion in the detection of significant coronary artery disease: cutoff values and diagnostic accuracy of quantitative [(15)O]H2O PET imaging. J Am Coll Cardiol  2014; 64: 1464– 1475. Google Scholar CrossRef Search ADS PubMed  53 Gerber BL, Ordoubadi FF, Wijns W, Vanoverschelde JL, Knuuti MJ, Janier M, Melon P, Blanksma PK, Bol A, Bax JJ, Melin JA, Camici PG. Positron emission tomography using (18)F-fluoro-deoxyglucose and euglycaemic hyperinsulinaemic glucose clamp: optimal criteria for the prediction of recovery of post-ischaemic left ventricular dysfunction. Results from the European community concerted action multicenter study on use of (18)F-fluoro-deoxyglucose positron emission tomography for the detection of myocardial viability. Eur Heart J  2001; 22: 1691– 1701. Google Scholar CrossRef Search ADS PubMed  54 Gould KL, Pan T, Loghin C, Johnson NP, Sdringola S. Reducing radiation dose in rest-stress cardiac PET/CT by single poststress cine CT for attenuation correction: quantitative validation. J Nucl Med  2008; 49: 738– 745. Google Scholar CrossRef Search ADS PubMed  55 Nieman K, Coenen A, Dijkshoorn ML. Computed tomography. In: K Nieman, O Gamperli, P Lancellotti, S Plein, eds. Advanced Cardiac Imaging . Cambridge: Woodhead Publishing; 2015. p 97– 103. Google Scholar CrossRef Search ADS   56 Halliburton SS, Abbara S, Chen MY, Gentry R, Mahesh M, Raff GL, Shaw LJ, Hausleiter J; Society of Cardiovascular Computed Tomography. SCCT guidelines on radiation dose and dose optimization strategies in cardiovascular CT. J Cardiovasc Computed Tomogr  2011; 4: 198– 202. Google Scholar CrossRef Search ADS   57 Buechel RR, Husmann L, Herzog BA, Pazhenkottil AP, Nkoulou R, Ghadri JR, Treyer V, von Schulthess P, Kaufmann PA. Low-dose computed tomography coronary angiography with prospective electrocardiogram triggering: feasibility in a large population. J Am Coll Cardiol  2011; 57: 332– 336. Google Scholar CrossRef Search ADS PubMed  58 Maruyama T, Takada M, Hasuike T, Yoshikawa A, Namimatsu E, Yoshizumi T. Radiation dose reduction and coronary assessability of prospective electrocardiogram-gated computed tomography coronary angiography: comparison with retrospective electrocardiogram-gated helical scan. J Am Coll Cardiol  2008; 52: 1450– 1455. Google Scholar CrossRef Search ADS PubMed  59 Gaemperli O, Schepis T, Valenta I, Husmann L, Scheffel H, Duerst V, Eberli FR, Luscher TF, Alkadhi H, Kaufmann PA. Cardiac image fusion from stand-alone SPECT and CT: clinical experience. J Nucl Med  2007; 48: 696– 703. Google Scholar CrossRef Search ADS PubMed  60 Liga R, Vontobel J, Rovai D, Marinelli M, Caselli C, Pietila M, Teresinska A, Aguadé-Bruix S, Pizzi MN, Todiere G, Gimelli A, Chiappino D, Marraccini P, Schroeder S, Drosch T, Poddighe R, Casolo G, Anagnostopoulos C, Pugliese F, Rouzet F, Le Guludec D, Cappelli F, Valente S, Gensini GF, Zawaideh C, Capitanio S, Sambuceti G, Marsico F, Filardi PP, Fernández-Golfín C, Rincón LM, Graner FP, de Graaf MA, Stehli J, Reyes E, Nkomo S, Mäki M, Lorenzoni V, Turchetti G, Carpeggiani C, Puzzuoli S, Mangione M, Marcheschi P, Giannessi D, Nekolla S, Lombardi M, Sicari R, Scholte AJ, Zamorano JL, Underwood SR, Knuuti J, Kaufmann PA, Neglia D, Gaemperli O; EVINCI Study Investigators. Multicentre multi-device hybrid imaging study of coronary artery disease: results from the EValuation of INtegrated Cardiac Imaging for the Detection and Characterization of Ischaemic Heart Disease (EVINCI) hybrid imaging population. Eur Heart J Cardiovasc Imaging  2016; 17: 951– 960. Google Scholar CrossRef Search ADS PubMed  61 Benz DC, Templin C, Kaufmann PA, Buechel RR. Ultra-low-dose hybrid single photon emission computed tomography and coronary computed tomography angiography: A comprehensive and non-invasive diagnostic workup of suspected coronary artery disease. Eur Heart J  2015; 36: 3345– 3348. Google Scholar CrossRef Search ADS PubMed  62 Gaemperli O, Bengel FM, Kaufmann PA. Cardiac hybrid imaging. Eur Heart J  2011; 32: 2100– 2108. Google Scholar CrossRef Search ADS PubMed  63 Depuey EG, Mahmarian JJ, Miller TD, Einstein AJ, Hansen CL, Holly TA, Miller EJ, Polk DM, Samuel Wann L. Patient-centered imaging. J Nucl Cardiol  2012; 19: 185– 215. Google Scholar CrossRef Search ADS PubMed  64 Task Force Members, Montalescot G, Sechtem U, Achenbach S, Andreotti F, Arden C, Budaj A, Bugiardini R, Crea F, Cuisset T, Di Mario C, Ferreira JR, Gersh BJ, Gitt AK, Hulot JS, Marx N, Opie LH, Pfisterer M, Prescott E, Ruschitzka F, Sabaté M, Senior R, Taggart DP, van der WEE, Vrints CJ ESC Committee for Practice Guidelines Zamorano JL, Achenbach S, Baumgartner H, Bax JJ, Bueno H, Dean V, Deaton C, Erol C, Fagard R, Ferrari R, Hasdai D, Hoes AW, Kirchhof P, Knuuti J, Kolh P, Lancellotti P, Linhart A, Nihoyannopoulos P, Piepoli MF, Ponikowski P, Sirnes PA, Tamargo JL, Tendera M, Torbicki A, Wijns W, Windecker S; Document Reviewers, Knuuti J, Valgimigli M, Bueno H, Claeys MJ, Donner-Banzhoff N, Erol C, Frank H, Funck-Brentano C, Gaemperli O, Gonzalez-Juanatey JR, Hamilos M, Hasdai D, Husted S, James SK, Kervinen K, Kolh P, Kristensen SD, Lancellotti P, Maggioni AP, Piepoli MF, Pries AR, Romeo F, Rydén L, Simoons ML, Sirnes PA, Steg PG, Timmis A, Wijns W, Windecker S, Yildirir A, Zamorano JL. 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J  2013; 34: 2949– 3003. Google Scholar CrossRef Search ADS PubMed  65 Fiechter M, Stehli J, Fuchs TA, Dougoud S, Gaemperli O, Kaufmann PA. Impact of cardiac magnetic resonance imaging on human lymphocyte DNA integrity. Eur Heart J  2013; 34: 2340– 2345. Google Scholar CrossRef Search ADS PubMed  66 Lancellotti P, Nchimi A, Delierneux C, Hego A, Gosset C, Gothot A, Jean-Flory Tshibanda L, Oury C. Biological effects of cardiac magnetic resonance on human blood cells. Circ Cardiovasc Imaging  2015; 8: e003697. Google Scholar CrossRef Search ADS PubMed  67 Gimelli A, Lancellotti P, Badano LP, Lombardi M, Gerber B, Plein S, Neglia D, Edvardsen T, Kitsiou A, Scholte AJ, Schröder S, Cosyns B, Gargiulo P, Zamorano JL, Perrone-Filardi P. Non-invasive cardiac imaging evaluation of patients with chronic systolic heart failure: a report from the European Association of Cardiovascular Imaging (EACVI). Eur Heart J  2014; 35: 3417– 3425. Google Scholar CrossRef Search ADS PubMed  68 Garbi M, Edvardsen T, Bax J, Petersen SE, McDonagh T, Filippatos G, Lancellotti P; Reviewer Panel. EACVI appropriateness criteria for the use of cardiovascular imaging in heart failure derived from European National Imaging Societies voting. Eur Heart J Cardiovasc Imaging  2016; 17: 711– 721. Google Scholar CrossRef Search ADS PubMed  69 Habib G, Lancellotti P, Antunes MJ, Bongiorni MG, Casalta JP, Del Zotti F, Dulgheru R, El Khoury G, Erba PA, Iung B, Miro JM, Mulder BJ, Plonska-Gosciniak E, Price S, Roos-Hesselink J, Snygg-Martin U, Thuny F, Tornos Mas P, Vilacosta I, Zamorano JL; Document Reviewers, Erol Ç, Nihoyannopoulos P, Aboyans V, Agewall S, Athanassopoulos G, Aytekin S, Benzer W, Bueno H, Broekhuizen L, Carerj S, Cosyns B, De Backer J, De Bonis M, Dimopoulos K, Donal E, Drexel H, Flachskampf FA, Hall R, Halvorsen S, Hoen B, Kirchhof P, Lainscak M, Leite-Moreira AF, Lip GY, Mestres CA, Piepoli MF, Punjabi PP, Rapezzi C, Rosenhek R, Siebens K, Tamargo J, Walker DM. 2015 ESC guidelines for the management of infective endocarditis: the task force for the management of infective endocarditis of the European Society of Cardiology (ESC). Endorsed by: European Association for Cardio-Thoracic Surgery (EACTS), the European Association of Nuclear Medicine (EANM). Eur Heart J  2015; 36: 3075– 3128. Google Scholar CrossRef Search ADS PubMed  70 Karunanithi S, Sharma P, Bal C, Kumar R. (18)F-FDG PET/CT for diagnosis and treatment response evaluation in large vessel vasculitis. Eur J Nucl Med Mol Imaging  2014; 41: 586– 587. Google Scholar CrossRef Search ADS PubMed  71 Piepoli MF, Hoes AW, Agewall S, Albus C, Brotons C, Catapano AL, Cooney MT, Corrà U, Cosyns B, Deaton C, Graham I, Hall MS, Hobbs FD, Løchen ML, Löllgen H, Marques-Vidal P, Perk J, Prescott E, Redon J, Richter DJ, Sattar N, Smulders Y, Tiberi M, van der Worp HB, van Dis I, Verschuren WM; Authors/Task Force Members. 2016 European guidelines on cardiovascular disease prevention in clinical practice: the sixth Joint Task Force of the European Society of Cardiology and Other Societies on Cardiovascular Disease Prevention in Clinical Practice (constituted by representatives of 10 societies and by invited experts) developed with the special contribution of the European Association for Cardiovascular Prevention & Rehabilitation (EACPR). Eur Heart J  2016; 37: 2315– 2381. Google Scholar CrossRef Search ADS PubMed  72 Chest pain of recent onset: assessment and diagnosis. https://www.nice.org.uk/guidance/CG9 (5 November 2016). 73 Al-Mallah MH, Aljizeeri A, Villines TC, Srichai MB, Alsaileek A. Cardiac computed tomography in current cardiology guidelines. J Cardiovasc Comput Tomogr  2015; 9: 514– 523. Google Scholar CrossRef Search ADS PubMed  74 Roffi M, Patrono C, Collet JP, Mueller C, Valgimigli M, Andreotti F, Bax JJ, Borger MA, Brotons C, Chew DP, Gencer B, Hasenfuss G, Kjeldsen K, Lancellotti P, Landmesser U, Mehilli J, Mukherjee D, Storey RF, Windecker S, Baumgartner H, Gaemperli O, Achenbach S, Agewall S, Badimon L, Baigent C, Bueno H, Bugiardini R, Carerj S, Casselman F, Cuisset T, Erol Ç, Fitzsimons D, Halle M, Hamm C, Hildick-Smith D, Huber K, Iliodromitis E, James S, Lewis BS, Lip GY, Piepoli MF, Richter D, Rosemann T, Sechtem U, Steg PG, Vrints C, Luis Zamorano J. 2015 ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: task force for the management of acute coronary syndromes in patients presenting without persistent ST segment elevation of the European Society of Cardiology (ESC). Eur Heart J  2016; 37: 267– 315. Google Scholar CrossRef Search ADS PubMed  75 Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Baron-Esquivias G, Baumgartner H, Borger MA, Carrel TP, De Bonis M, Evangelista A, Falk V, Iung B, Lancellotti P, Pierard L, Price S, Schafers H-J, Schuler G, Stepinska J, Swedberg K, Takkenberg J, Von Oppell UO, Windecker S, Zamorano JL, Zembala M, Bax JJ, Baumgartner H, Ceconi C, Dean V, Deaton C, Fagard R, Funck-Brentano C, Hasdai D, Hoes A, Kirchhof P, Knuuti J, Kolh P, McDonagh T, Moulin C, Popescu BA, Reiner Z, Sechtem U, Sirnes PA, Tendera M, Torbicki A, Vahanian A, Windecker S, Popescu BA, Von Segesser L, Badano LP, Bunc M, Claeys MJ, Drinkovic N, Filippatos G, Habib G, Kappetein AP, Kassab R, Lip GYH, Moat N, Nickenig G, Otto CM, Pepper J, Piazza N, Pieper PG, Rosenhek R, Shuka N, Schwammenthal E, Schwitter J, Mas PT, Trindade PT, Walther T. Joint task force on the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Guidelines on the management of valvular heart disease (version 2012). Eur Heart J  2012; 33: 2451– 2496. Google Scholar CrossRef Search ADS PubMed  76 Camm AJ, Lip GY, De Caterina R, Savelieva I, Atar D, Hohnloser SH, Hindricks G, Kirchhof P; ESC Committee for Practice Guidelines (CPG). Guidelines 2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation. Developed with the special contribution of the European Heart Rhythm Association. Eur Heart J  2012; 33: 2719– 2727. Google Scholar CrossRef Search ADS PubMed  77 Adler Y, Charron P, Imazio M, Badano L, Barón-Esquivias G, Bogaert J, Brucato A, Gueret P, Klingel K, Lionis C, Maisch B, Mayosi B, Pavie A, Ristić AD, Sabaté Tenas M, Seferovic P, Swedberg K, Tomkowski W, Achenbach S, Agewall S, Al-Attar N, Angel Ferrer J, Arad M, Asteggiano R, Bueno H, Caforio AL, Carerj S, Ceconi C, Evangelista A, Flachskampf F, Giannakoulas G, Gielen S, Habib G, Kolh P, Lambrinou E, Lancellotti P, Lazaros G, Linhart A, Meurin P, Nieman K, Piepoli MF, Price S, Roos-Hesselink J, Roubille F, Ruschitzka F, Sagristà Sauleda J, Sousa-Uva M, Uwe Voigt J, Luis Zamorano J; European Society of Cardiology (ESC). 2015 ESC Guidelines for the diagnosis and management of pericardial diseases: the task force for the diagnosis and management of pericardial diseases of the European Society of Cardiology (ESC) endorsed by: the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J  2015; 36: 2921– 2964. Google Scholar CrossRef Search ADS PubMed  78 Medicare Part B imaging services: rapid spending growth and shift to physician offices indicate need for CMS to consider additional management practices. Washington, DC: Government Accountability Office. 2008. http://www.gao.gov/new.items/d08452.pdf (accessed 19 February 2016). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com. TI - Strategies for radiation dose reduction in nuclear cardiology and cardiac computed tomography imaging: a report from the European Association of Cardiovascular Imaging (EACVI), the Cardiovascular Committee of European Association of Nuclear Medicine (EANM), and the European Society of Cardiovascular Radiology (ESCR) JF - European Heart Journal DO - 10.1093/eurheartj/ehx582 DA - 2017-10-20 UR - https://www.deepdyve.com/lp/oxford-university-press/strategies-for-radiation-dose-reduction-in-nuclear-cardiology-and-1soYkmFQOr SP - 286 EP - 296 VL - 39 IS - 4 DP - DeepDyve ER -