Access the full text.
Sign up today, get DeepDyve free for 14 days.
S. Perlman, B. Messing, Y. Salem, S. Porat, R. Achiron, Y. Gilboa (2017)
The added value of f‐TAPSE in the surveillance of pregnancies complicated by fetal and placental tumorsPrenatal Diagnosis, 37
N. Hamill, L. Yeo, R. Romero, S. Hassan, S. Myers, P. Mittal, J. Kusanovic, M. Balasubramaniam, T. Chaiworapongsa, E. Vaisbuch, J. Espinoza, F. Gotsch, L. Goncalves, Wesley Lee (2011)
Fetal cardiac ventricular volume, cardiac output, and ejection fraction determined with 4-dimensional ultrasound using spatiotemporal image correlation and virtual organ computer-aided analysis.American journal of obstetrics and gynecology, 205 1
H. Gardiner, L. Pasquini, J. Wolfenden, A. Barlow, Wei Li, E. Kulinskaya, M. Henein (2006)
Myocardial tissue Doppler and long axis function in the fetal heart.International journal of cardiology, 113 1
T. Mieghem, R. Hodges, E. Jaeggi, G. Ryan (2014)
Functional echocardiography in the fetus with non‐cardiac diseasePrenatal Diagnosis, 34
A. Gornall, J. Kurinczuk, J. Konje (2003)
Antenatal detection of a single umbilical artery: does it matter?Prenatal Diagnosis, 23
F. Crispi, E. Gratacós (2012)
Fetal Cardiac Function: Technical Considerations and Potential Research and Clinical ApplicationsFetal Diagnosis and Therapy, 32
Y. Mao, Bowen Zhao, Bei Wang (2016)
Z-Score Reference Ranges for Angular M-Mode Displacement at 22-40 Weeks' GestationFetal Diagnosis and Therapy, 41
(2013)
AIUM Practice Guideline for the Performance of Fetal EchocardiographyJournal of Ultrasound in Medicine, 32
T. Moore, Jonathan Cayle (1990)
The amniotic fluid index in normal human pregnancy.American journal of obstetrics and gynecology, 162 5
J. Carvalho, C. O'Sullivan, E. Shinebourne, M. Henein (2001)
Right and left ventricular long‐axis function in the fetus using angular M‐modeUltrasound in Obstetrics and Gynecology, 18
M. Koestenberger, W. Ravekes, A. Everett, H. Stueger, B. Heinzl, A. Gamillscheg, G. Cvirn, A. Boysen, A. Fandl, B. Nagel (2009)
Right ventricular function in infants, children and adolescents: reference values of the tricuspid annular plane systolic excursion (TAPSE) in 640 healthy patients and calculation of z score values.Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography, 22 6
N. Bravo-Valenzuela, A. Peixoto, L. Nardozza, A. Souza, E. Júnior (2017)
Applicability and technical aspects of two-dimensional ultrasonography for assessment of fetal heart function.Medical ultrasonography, 19 1
M. Cruz-Lemini, F. Crispi, B. Valenzuela-Alcaraz, F. Figueras, M. Sitges, Olga Gómez, Bart Bijnens, E. Gratacós (2013)
Value of annular M‐mode displacement vs tissue Doppler velocities to assess cardiac function in intrauterine growth restrictionUltrasound in Obstetrics & Gynecology, 42
D. Altman, L. Chitty (1994)
Charts of fetal size: 1. MethodologyBJOG: An International Journal of Obstetrics & Gynaecology, 101
C. Breatnach, P. Levy, A. James, O. Franklin, A. El-Khuffash (2016)
Novel Echocardiography Methods in the Functional Assessment of the Newborn HeartNeonatology, 110
A. Lee‐Tannock, K. Hay, A. Gooi, Sailesh Kumar (2019)
Longitudinal Reference Ranges for Tricuspid Annular Plane Systolic Excursion and Mitral Annular Plane Systolic Excursion in Normally Grown FetusesJournal of Ultrasound in Medicine, 39
L. Bergenzaun, H. Öhlin, P. Gudmundsson, R. Willenheimer, M. Chew (2013)
Mitral annular plane systolic excursion (MAPSE) in shock: a valuable echocardiographic parameter in intensive care patientsCardiovascular Ultrasound, 11
J. Carvalho, L. Allan, R. Chaoui, J. Copel, G. Devore, K. Hecher, W. Lee, H. Muñoz, D. Paladini, B. Tutschek, S. Yagel (2013)
ISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heartUltrasound in Obstetrics & Gynecology, 41
I. Germanakis, Spyridon Pepes, S. Sifakis, H. Gardiner (2012)
Fetal Longitudinal Myocardial Function Assessment by Anatomic M-ModeFetal Diagnosis and Therapy, 32
P. Royston, E. Wright (1998)
How to construct ‘normal ranges’ for fetal variablesUltrasound in Obstetrics and Gynecology, 11
C. Allen, R. Keller, K. Barnard, Zhiqian Gao, E. King, E. Michelfelder (2018)
Test–retest variability for quantitative two‐dimensional and Doppler measurements in the fetusEchocardiography, 36
M. Koestenberger, W. Raith, W. Ravekes (2013)
Importance of quantifiable right heart systolic function evaluation using tricuspid annular plane systolic excursion (TAPSE) in fetuses and neonatesUltrasound in Obstetrics & Gynecology, 42
Luís Gonçalves, Wesley Lee, Jimmy Espinoza, Roberto Romero (2006)
How do we do it? Practical advice on imaging‐based techniques and investigationsUltrasound in Obstetrics & Gynecology, 27
H. Gardiner, L. Pasquini, J. Wolfenden, E. Kulinskaya, W. Li, M. Henein (2005)
Increased periconceptual maternal glycated haemoglobin in diabetic mothers reduces fetal long axis cardiac functionHeart, 92
C. Zanardini, F. D’Antonio, B. Hvingel, Å. Vårtun, F. Prefumo, M. Flacco, L. Manzoli, G. Acharya (2019)
Agreement between anatomical M‐mode and tissue Doppler imaging in the assessment of fetal atrioventricular annular plane displacement in uncomplicated pregnancies: A prospective longitudinal studyJournal of Obstetrics and Gynaecology Research, 45
W. Martins, C. Nastri (2014)
Interpreting reproducibility results for ultrasound measurementsUltrasound in Obstetrics & Gynecology, 43
J. Ortiz, F. Crispi, R. Yamamoto, N. Masoller, M. Cruz-Lemini, O. Gómez, M. Bennasar, S. Lobmaier, E. Eixarch, Josep Martínez, E. Gratacós (2015)
Longitudinal annular displacement by M‐mode (MAPSE and TAPSE) in twin‐to‐twin transfusion syndrome before and after laser surgeryPrenatal Diagnosis, 35
L. Degos, J. Dausset (1974)
HISTOCOMPATIBILITY DETERMINANTS IN MULTIPLE SCLEROSISThe Lancet, 303
Rev Esp Cardiol, 63
B. Messing, Y. Gilboa, M. Lipschuetz, D. Valsky, S. Cohen, S. Yagel (2013)
Fetal tricuspid annular plane systolic excursion (f‐TAPSE): evaluation of fetal right heart systolic function with conventional M‐mode ultrasound and spatiotemporal image correlation (STIC) M‐modeUltrasound in Obstetrics & Gynecology, 42
Marta Pinedo, Eduardo Villacorta, C. Tapia, Roman Arnold, Javier López, A. Revilla, Itziar Gómez, E. Fulquet, J. Román (2010)
Variabilidad inter e intraobservador en la valoración ecocardiográfica de la función del ventrículo derechoRevista Espanola De Cardiologia, 63
Tian-gang Li, F. Nie, Zhen-dong Li, Yanfang Wang, Qi Li (2019)
Evaluation of right ventricular function in fetuses with isolated single umbilical artery using spatiotemporal image correlation M-modeCardiovascular Ultrasound, 17
F. Hadlock, F. Hadlock, R. Harrist, R. Harrist, R. Sharman, R. Sharman, R. Deter, R. Deter, Seung-Ku Park, Seung-Ku Park (1985)
Estimation of fetal weight with the use of head, body, and femur measurements--a prospective study.American journal of obstetrics and gynecology, 151 3
AbstractObjectivesThis study aimed to establish reference ranges for fetal mitral, tricuspid, and interventricular septum annular plane systolic excursions (MAPSE, TAPSE, and SAPSE) in normal pregnant women between 20 and 36 + 6 weeks of gestation.MethodsThis prospective and cross-sectional study included 360 low-risk singleton pregnancies between 20 and 36 + 6 weeks of gestation. MAPSE, TAPSE, and SAPSE were measured by M-mode in real time in an apical or basal four-chamber view through placing the cursor at the atrioventricular junction, marked by the valve rings at the tricuspid, mitral, and basal septum, respectively. A regression analysis was done to determine the appropriate polynomial equation model for both measurements and standard deviation (SD) values in relation to gestational age (GA). The intra- and inter-observer reproducibility was evaluated using the concordance correlation coefficient (CCC) and limits of agreement (LoA).ResultsThere was a significant positive correlation between MAPSE (r=0.705, p<0.0001), TAPSE (r=0.804, p<0.0001), and SAPSE (r=0.690, p<0.0001) and GA. The mean of each parameter ranged as follows: 2.87–5.56 mm, MAPSE; 3.98–8.07 mm, TAPSE; and 2.34–4.21 mm, SAPSE. Poor/moderate intra- and inter-observer reliability (CCC between 0.70 and 0.90) and poor/moderate agreement of all the tested parameters were evaluated (LoA between 10 and 50%).ConclusionsReference values were established for the fetal MAPSE, TAPSE, and SAPSE between 20 and 36 + 6 weeks of gestation in low-risk pregnant women. These parameters showed poor/moderate reproducibility.
Journal of Perinatal Medicine – de Gruyter
Published: Jul 28, 2020
Keywords: fetal heart; MAPSE; M-mode; reference ranges; SAPSE; TAPSE
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.