Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Reference ranges for the fetal mitral, tricuspid, and interventricular septum annular plane systolic excursions (mitral annular plane systolic excursion, tricuspid annular plane systolic excursion, and septum annular plane systolic excursion) between 20 and 36 + 6 weeks of gestation

Reference ranges for the fetal mitral, tricuspid, and interventricular septum annular plane... AbstractObjectivesThis study aimed to establish reference ranges for fetal mitral, tricuspid, and interventricular septum annular plane systolic excursions (MAPSE, TAPSE, and SAPSE) in normal pregnant women between 20 and 36 + 6 weeks of gestation.MethodsThis prospective and cross-sectional study included 360 low-risk singleton pregnancies between 20 and 36 + 6 weeks of gestation. MAPSE, TAPSE, and SAPSE were measured by M-mode in real time in an apical or basal four-chamber view through placing the cursor at the atrioventricular junction, marked by the valve rings at the tricuspid, mitral, and basal septum, respectively. A regression analysis was done to determine the appropriate polynomial equation model for both measurements and standard deviation (SD) values in relation to gestational age (GA). The intra- and inter-observer reproducibility was evaluated using the concordance correlation coefficient (CCC) and limits of agreement (LoA).ResultsThere was a significant positive correlation between MAPSE (r=0.705, p<0.0001), TAPSE (r=0.804, p<0.0001), and SAPSE (r=0.690, p<0.0001) and GA. The mean of each parameter ranged as follows: 2.87–5.56 mm, MAPSE; 3.98–8.07 mm, TAPSE; and 2.34–4.21 mm, SAPSE. Poor/moderate intra- and inter-observer reliability (CCC between 0.70 and 0.90) and poor/moderate agreement of all the tested parameters were evaluated (LoA between 10 and 50%).ConclusionsReference values were established for the fetal MAPSE, TAPSE, and SAPSE between 20 and 36 + 6 weeks of gestation in low-risk pregnant women. These parameters showed poor/moderate reproducibility. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Perinatal Medicine de Gruyter

Reference ranges for the fetal mitral, tricuspid, and interventricular septum annular plane systolic excursions (mitral annular plane systolic excursion, tricuspid annular plane systolic excursion, and septum annular plane systolic excursion) between 20 and 36 + 6 weeks of gestation

Loading next page...
 
/lp/de-gruyter/reference-ranges-for-the-fetal-mitral-tricuspid-and-interventricular-cxebPn2l1d

References (33)

Publisher
de Gruyter
Copyright
© 2020 Walter de Gruyter GmbH, Berlin/Boston
ISSN
0300-5577
eISSN
1619-3997
DOI
10.1515/jpm-2020-0002
Publisher site
See Article on Publisher Site

Abstract

AbstractObjectivesThis study aimed to establish reference ranges for fetal mitral, tricuspid, and interventricular septum annular plane systolic excursions (MAPSE, TAPSE, and SAPSE) in normal pregnant women between 20 and 36 + 6 weeks of gestation.MethodsThis prospective and cross-sectional study included 360 low-risk singleton pregnancies between 20 and 36 + 6 weeks of gestation. MAPSE, TAPSE, and SAPSE were measured by M-mode in real time in an apical or basal four-chamber view through placing the cursor at the atrioventricular junction, marked by the valve rings at the tricuspid, mitral, and basal septum, respectively. A regression analysis was done to determine the appropriate polynomial equation model for both measurements and standard deviation (SD) values in relation to gestational age (GA). The intra- and inter-observer reproducibility was evaluated using the concordance correlation coefficient (CCC) and limits of agreement (LoA).ResultsThere was a significant positive correlation between MAPSE (r=0.705, p<0.0001), TAPSE (r=0.804, p<0.0001), and SAPSE (r=0.690, p<0.0001) and GA. The mean of each parameter ranged as follows: 2.87–5.56 mm, MAPSE; 3.98–8.07 mm, TAPSE; and 2.34–4.21 mm, SAPSE. Poor/moderate intra- and inter-observer reliability (CCC between 0.70 and 0.90) and poor/moderate agreement of all the tested parameters were evaluated (LoA between 10 and 50%).ConclusionsReference values were established for the fetal MAPSE, TAPSE, and SAPSE between 20 and 36 + 6 weeks of gestation in low-risk pregnant women. These parameters showed poor/moderate reproducibility.

Journal

Journal of Perinatal Medicinede Gruyter

Published: Jul 28, 2020

Keywords: fetal heart; MAPSE; M-mode; reference ranges; SAPSE; TAPSE

There are no references for this article.