Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Characteristics of the Sony Multiscan 17se Trinitron color graphic display

Characteristics of the Sony Multiscan 17se Trinitron color graphic display Characteristics of the Sony Multiscan 17se Trinitron color graphic display DAVID L. BOHNSACK,1,2,* LISA C. DILLER,1 TSAIYAO YEH,1 JAMES W. JENNESS3 and JOHN B. TROY1 1Biomedical Engineering Department, Robert R. McCormick School of Engineering and Applied Sciences, Northwestern University, Evanston, IL 60208-3107, USA 2RDI Software, 1400 East Touhy Avenue, Des Plaines, Illinois 60018-3375, USA 3Department of Psychology, College of Wooster, Wooster, OH 44691-2363, USA Received 3 January 1996; revised 2 September 1996; accepted 7 September 1996 Abstract-Technical measurements of the Sony Multiscan 17se were made and are reported in the belief that they would be useful to visual scientists who consider employing this device as a display unit. Luminance, spatial uniformity, luminance additivity between the output of the guns, CIE1931 chromaticity coordinates, and gamma correction parameters were measured. The characteristics of individual monitors will probably be different from the one studied here but it is believed that the results obtained serve as a fair indication of what might be expected from this device. 1. INTRODUCTION Research in visual science would be aided significantly by the availability of an inex- pensive and reliable display unit with a fast non-interlaced refresh rate. For the past eighteen months we have been http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Spatial Vision (continued as Seeing & Perceiving from 2010) Brill

Characteristics of the Sony Multiscan 17se Trinitron color graphic display

Loading next page...
 
/lp/brill/characteristics-of-the-sony-multiscan-17se-trinitron-color-graphic-ceAc2G9ckm

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
Brill
Copyright
© 1997 Koninklijke Brill NV, Leiden, The Netherlands
ISSN
0169-1015
eISSN
1568-5683
DOI
10.1163/156856897X00267
Publisher site
See Article on Publisher Site

Abstract

Characteristics of the Sony Multiscan 17se Trinitron color graphic display DAVID L. BOHNSACK,1,2,* LISA C. DILLER,1 TSAIYAO YEH,1 JAMES W. JENNESS3 and JOHN B. TROY1 1Biomedical Engineering Department, Robert R. McCormick School of Engineering and Applied Sciences, Northwestern University, Evanston, IL 60208-3107, USA 2RDI Software, 1400 East Touhy Avenue, Des Plaines, Illinois 60018-3375, USA 3Department of Psychology, College of Wooster, Wooster, OH 44691-2363, USA Received 3 January 1996; revised 2 September 1996; accepted 7 September 1996 Abstract-Technical measurements of the Sony Multiscan 17se were made and are reported in the belief that they would be useful to visual scientists who consider employing this device as a display unit. Luminance, spatial uniformity, luminance additivity between the output of the guns, CIE1931 chromaticity coordinates, and gamma correction parameters were measured. The characteristics of individual monitors will probably be different from the one studied here but it is believed that the results obtained serve as a fair indication of what might be expected from this device. 1. INTRODUCTION Research in visual science would be aided significantly by the availability of an inex- pensive and reliable display unit with a fast non-interlaced refresh rate. For the past eighteen months we have been

Journal

Spatial Vision (continued as Seeing & Perceiving from 2010)Brill

Published: Jan 1, 1997

There are no references for this article.