Monitoring the respiratory rate of preterm infants using an ultrathin film sensor embedded in the bedding: a comparative feasibility study

Monitoring the respiratory rate of preterm infants using an ultrathin film sensor embedded in the... Objective: To determine the feasibility of unobtrusively monitoring the respiratory rate (RR) in preterm infants by using a film-like pressure sensor placed between the mattress and the bedding. Approach: The RR was simultaneously measured by processing the chest impedance (CI) and the ballistographic (BSG) signal acquired from the pressure sensor in 10 preterm infants of varying body weight. Nearly 27 h of data were analyzed from these infants while in different body positions including both spontaneously breathing infants and those receiving non-invasive respiratory support. Main results: The RR acquired from the BSG signal (RR-BSG) was significantly correlated (r  =  0.74) to the RR derived from the CI (RR-CI) with narrow 95% limits of agreement (10 breaths min−1). A subanalysis of epochs most and least affected by infant movement yielded comparable results. Significance: Irrespective of body weight or infant position, unobtrusively monitoring the RR of preterm infants is feasible using film-like pressure sensors. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Physiological Measurement IOP Publishing

Monitoring the respiratory rate of preterm infants using an ultrathin film sensor embedded in the bedding: a comparative feasibility study

Loading next page...
 
/lp/iop-publishing/monitoring-the-respiratory-rate-of-preterm-infants-using-an-ultrathin-7DAHD39TVe

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Copyright
Copyright © 2019 Institute of Physics and Engineering in Medicine
ISSN
0967-3334
eISSN
1361-6579
DOI
10.1088/1361-6579/ab1595
Publisher site
See Article on Publisher Site

Abstract

Objective: To determine the feasibility of unobtrusively monitoring the respiratory rate (RR) in preterm infants by using a film-like pressure sensor placed between the mattress and the bedding. Approach: The RR was simultaneously measured by processing the chest impedance (CI) and the ballistographic (BSG) signal acquired from the pressure sensor in 10 preterm infants of varying body weight. Nearly 27 h of data were analyzed from these infants while in different body positions including both spontaneously breathing infants and those receiving non-invasive respiratory support. Main results: The RR acquired from the BSG signal (RR-BSG) was significantly correlated (r  =  0.74) to the RR derived from the CI (RR-CI) with narrow 95% limits of agreement (10 breaths min−1). A subanalysis of epochs most and least affected by infant movement yielded comparable results. Significance: Irrespective of body weight or infant position, unobtrusively monitoring the RR of preterm infants is feasible using film-like pressure sensors.

Journal

Physiological MeasurementIOP Publishing

Published: Apr 1, 2019

There are no references for this article.