Heirali, Alya; Mehta, Sangeeta; Li, Yiyan; Rochwerg, Bram; Maratta, Christina; Charbonney, Emmanuel; Burns, Karen E. A.; O’Hearn, Katie; Menon, Kusum; Fowler, Rob; Mohsen, Samiha; Murthy, Srinivas; Fiest, Kirsten M.; ,
Dana, Elad; Arzola, Cristian; Khan, James S.
doi: 10.1007/s12630-024-02748-8pmid: 38480632
PurposeHypotension after induction of general anesthesia (GAIH) is common and is associated with postoperative complications including increased mortality. Collapsibility of the inferior vena cava (IVC) has good performance in predicting GAIH; however, there is limited evidence whether a preoperative fluid bolus in patients with a collapsible IVC can prevent this drop in blood pressure.MethodsWe conducted a single-centre randomized controlled trial with adult patients scheduled to undergo elective noncardiac surgery under general anesthesia (GA). Patients underwent a preoperative point-of-care ultrasound scan (POCUS) to identify those with a collapsible IVC (IVC collapsibility index ≥ 43%). Individuals with a collapsible IVC were randomized to receive a preoperative 500 mL fluid bolus or routine care (control group). Surgical and anesthesia teams were blinded to the results of the scan and group allocation. Hypotension after induction of GA was defined as the use of vasopressors/inotropes or a decrease in mean arterial pressure < 65 mm Hg or > 25% from baseline within 20 min of induction of GA.ResultsForty patients (20 in each group) were included. The rate of hypotension after induction of GA was significantly reduced in those receiving preoperative fluids (9/20, 45% vs 17/20, 85%; relative risk, 0.53; 95% confidence interval, 0.32 to 0.89; P = 0.02). The mean (standard deviation) time to complete POCUS was 4 (2) min, and the duration of fluid bolus administration was 14 (5) min. Neither surgical delays nor adverse events occurred as a result of the study intervention.ConclusionA preoperative fluid bolus in patients with a collapsible IVC reduced the incidence of GAIH without associated adverse effects.Study registrationClinicalTrials.gov (NCT05424510); first submitted 15 June 2022.
Mizubuti, Glenio B.; e Lima, Lais H. N.; e Lima, Rodrigo M.; Ho, Adrienne K.; de Cássia Rodrigues, Rita; Cagnolati, Daniel Carlos; dos Santos Júnior, Victório; Belfiore, Elio B. R.; Santos, Filipe N. C.; Lam, Wai Shun Vincent; Chu, Mandy; Korz, Linda T. C.; Szulewski, Adam;
Nelms, Matthew W.; Javidan, Arshia; Chin, Ki Jinn; Vignarajah, Muralie; Zhou, Fangwen; Tian, Chenchen; Lee, Yung; Kayssi, Ahmed; Naji, Faysal; Singh, Mandeep
doi: 10.1007/s12630-024-02791-5pmid:
Cho, Eunah; Roh, Yun Ho; Moon, Jisu; Kim, Yangjin; Shin, Seokyung
doi: 10.1007/s12630-024-02762-wpmid: 38671251
PurposeRemimazolam is a recently developed ultra-short-acting benzodiazepine used for anesthesia induction and maintenance. Nevertheless, the effective bolus dose of remimazolam for i-gel® (Intersurgical Ltd., Wokingham, Berkshire, UK) insertion without the use of neuromuscular blocking agents (NMBAs) has not been well established.MethodsThis study included 25 adult patients scheduled for surgery under general anesthesia who were eligible for i-gel use. Anesthesia was induced with predetermined bolus doses of remimazolam, starting at 0.3 mg·kg−1 for the first patient, without the use of NMBAs. All patients concurrently received remifentanil using target-controlled infusion (TCI) at a fixed effect-site concentration (Ce) of 3.0 ng·mL−1. Insertion of the i-gel was attempted 90 sec after remimazolam administration, and insertion conditions were assessed. Subsequent doses of remimazolam were decreased or increased by 0.05 mg·kg−1, depending on the success or failure of i-gel insertion.ResultsThe mean (standard deviation) 50% effective dose (ED50) of a remimazolam bolus for successful i-gel insertion as determined by the modified Dixon’s up-and-down method was 0.100 (0.027) mg·kg−1. The ED50 and ED95 estimated by isotonic regression were 0.111 (83% confidence interval [CI], 0.096 to 0.131) mg·kg−1 and 0.182 (95% CI, 0.144 to 0.195) mg·kg−1, respectively. None of the patients required treatment for hypotension or bradycardia during anesthesia induction.ConclusionBased on the ED95 of remimazolam bolus dose determined in our study, we recommend using 0.182 mg·kg−1 of remimazolam in combination with remifentanil TCI at a Ce of 3.0 ng·mL−1 for successful i-gel insertion without NMBAs in adult patients. This regimen seems effective with a low risk of hemodynamic instability during anesthesia induction.Study registrationClinicalTrials.gov (NCT05298228); first submitted 6 March 2022.
Shin, Kyung Won; Lee, Sang Phil; Kim, Taeyup; Choi, Seungeun; Kim, Yoon Jung; Park, Hee-Pyoung; Oh, Hyongmin
doi: 10.1007/s12630-024-02769-3pmid: 38777999
PurposeChannelled blades have the advantage of avoiding stylet use and potential airway injury during videolaryngoscopic intubation. Nevertheless, the effectiveness of channelled Macintosh-type blades has not yet been fully established. We sought to assess the utility of channelled Macintosh-type blades for videolaryngoscopic intubation under cervical spine immobilization.MethodsWe conducted a randomized controlled noninferiority trial in neurosurgical patients with a difficult airway simulated by a cervical collar. Videolaryngoscopic intubation with a reinforced tracheal tube was performed using a channelled Macintosh-type blade without a stylet (channelled group, n = 130) or a nonchannelled Macintosh-type blade with a stylet (nonchannelled group, n = 131). The primary outcome was intubation success rate. Secondary outcomes included time to intubation and incidence or severity of intubation-related complications (subglottic, lingual, and dental injuries; bleeding; sore throat; and hoarseness).ResultsThe initial intubation success rate was 98% and 99% in the channelled and nonchannelled groups, respectively, showing the noninferiority of the channelled group (difference in proportions −0.8%; 95% confidence interval [CI], −4.8% to 2.9%; predefined noninferiority margin, −5%; P = 0.62). Fewer participants in the channelled group had subglottic injuries than in the nonchannelled group (32% [32/100] vs 57% [54/95]; difference in proportions, −25%; 95% CI, −39% to −11%; P < 0.001). There were no significant differences between the two groups in the overall intubation success rate, time to intubation, and incidence or severity of other intubation-related complications.ConclusionsFor videolaryngoscopic intubation in patients with a cervical collar, channelled Macintosh-type blades are an alternative to nonchannelled Macintosh-type blades, with a noninferior initial intubation success rate and a lower incidence of subglottic injury.Study registrationCRIS.nih.go.kr (KCT0005186); first submitted 29 June 2020.
Tan, Hon Sen; Tan, Chin Wen; Sultana, Rehena; Yang, Lu; Mok, May U. S.; Sng, Ban Leong
doi: 10.1007/s12630-024-02799-xpmid: 39134784
PurposeRecent studies have reported the use of the obstetric-specific quality of recovery tool (ObsQoR-10) to assess the quality of recovery in parturients after childbirth; however, the correlation between ObsQoR-10 scores and important postpartum outcomes are unclear. The primary aim of the present study was to investigate the correlations between ObsQoR-10 scores at 24 hr after Cesarean delivery and breastfeeding, depressive symptomatology, overall health, and pain at seven days postpartum.MethodsWe recruited parturients who underwent elective Cesarean delivery at KK Hospital in Singapore. Parturients provided responses to post-Cesarean questionnaires at 1) 24 hr (ObsQoR-10, EuroQol EQ-Visual Analogue Scale, Edinburgh Postnatal Depression Scale), 2) 48 hr (ObsQoR-10, EQ-Visual Analogue Scale), and 3) seven days after Cesarean delivery (ObsQoR-10, Breastfeeding Self-Efficacy Scale-Short form, EQ-Visual Analogue Scale, Edinburgh Postnatal Depression Scale, pain survey).ResultsWe enrolled 222 participants, 200 (90%) of whom completed the seven-day follow-up between September 2022 and April 2023. There was limited correlation between ObsQoR-10 at 24 hr with the Edinburgh Postnatal Depression Scale (r = 0.135), EQ-Visual Analogue Scale (r = 0.158), Breastfeeding Self-Efficacy Scale-Short form (r = 0.225), and averaged pain scores (r = –0.107) at seven days postpartum. ObsQoR-10 breastfeeding sub-score at 24 hr was weakly correlated with Breastfeeding Self-Efficacy Scale-Short form at seven days postpartum (r = 0.307).ConclusionObsQoR-10 at 24 hr postpartum had limited correlation with breastfeeding, depressive symptomatology, overall health, and pain at seven days.Study registrationClinicalTrials.gov (NCT04989894); first submitted 4 July 2021.
Showing 1 to 10 of 22 Articles
doi: 10.1007/s12630-024-02824-zpmid: 39242476
PurposeEquity, Diversity, and Inclusion (EDI) initiatives within critical care research are limited by a lack of resources and inconsistent and rapidly changing language. The Canadian Critical Care Trials Group (CCCTG) is committed to modelling EDI for the critical care community through its programming, communications, protocols, and policies. The objective of developing the EDI glossary of sociodemographic determinants of health described here was to provide a resource for critical care professionals to support broader equity initiatives and to promote education and awareness about inclusive language.MethodsThrough literature review, we identified EDI-related sociodemographic determinants of health, defined as sociodemographic factors that are associated with disparities in health care and health outcomes, with a focus on critical care medicine. For each sociodemographic determinant of health, we identified umbrella terms (defined as domains) and subterms/constructs that are related to these domains. We designed the glossary collaboratively with the CCCTG EDI working group, patient and family partnerships committee, and executive committee, which included diverse knowledge users such as researchers, clinicians, and patient and family partners.ResultsWe report on 12 sociodemographic determinants of health domains including age, sex, gender, sexuality, race and ethnicity, income, education, employment status, marital status, language, disability, and migration status. Each domain (e.g., sex) contains relevant subterms such as male, female, intersex. For each domain, we provide examples of disparities in health care and health outcomes with a focus on critical care medicine.ConclusionsThis EDI glossary of sociodemographic determinants of health serves as a nonexhaustive resource that may be referenced by critical care researchers, research coordinators, clinicians, and patient and family partners. The glossary is an essential step to raising awareness about inclusive terminology and to fostering and advancing equity in critical care medicine.
doi: 10.1007/s12630-024-02788-0pmid: 38918271
PurposeMedical errors may be occasionally explained by inattentional blindness (IB), i.e., failing to notice an event/object that is in plain sight. We aimed to determine whether age/experience, restfulness/fatigue, and previous exposure to simulation education may affect IB in the anesthetic/surgical setting.MethodsIn this multicentre/multinational study, a convenience sample of 280 anesthesiologists watched an attention-demanding video of a simulated trauma patient undergoing laparotomy and (independently/anonymously) recorded the abnormalities they noticed. The video contained four expected/common abnormalities (hypotension, tachycardia, hypoxia, hypothermia) and two prominently displayed unexpected/rare events (patient’s head movement, leaky central venous line). We analyzed the participants’ ability to notice the expected/unexpected events (primary outcome) and the proportion of expected/unexpected events according to age group and prior exposure to simulation education (secondary outcomes).ResultsAnesthesiologists across all ages noticed fewer unexpected/rare events than expected/common ones. Overall, younger anesthesiologists missed fewer common events than older participants did (P = 0.02). There was no consistent association between age and perception of unexpected/rare events (P = 0.28), although the youngest cohort (< 30 yr) outperformed the other age groups. Prior simulation education did not affect the proportion of misses for the unexpected/rare events but was associated with fewer misses for the expected/common events. Self-perceived restfulness did not impact perception of events.ConclusionAnesthesiologists noticed fewer unexpected/rare clinical events than expected/common ones in an attention-demanding video of a simulated trauma patient, in keeping with IB. Prior simulation training was associated with an improved ability to notice anticipated/expected events, but did not reduce IB. Our findings may have implications for understanding medical mishaps, and efforts to improve situational awareness, especially in acute perioperative and critical care settings.
BackgroundOnline video sharing platforms like YouTube (Google LLC, San Bruno, CA, USA) have become a substantial source of health information. We sought to conduct a systematic review of studies assessing the overall quality of perioperative anesthesia videos on YouTube.MethodsWe searched Embase, MEDLINE, and Ovid for articles published from database inception to 1 May 2023. We included primary studies evaluating YouTube videos as a source of information regarding perioperative anesthesia. We excluded studies not published in English and studies assessing acute or chronic pain. Studies were screened and data were extracted in duplicate by two reviewers. We appraised the quality of studies according to the social media framework published in the literature. We used descriptive statistics to report the results using mean, standard deviation, range, and n/total N (%).ResultsAmong 8,908 citations, we identified 14 studies that examined 796 videos with 59.7 hr of content and 47.5 million views. Among the 14 studies that evaluated the video content quality, 17 different quality assessment tools were used, only three of which were externally validated (Global Quality Score, modified DISCERN score, and JAMA score). Per global assessment rating of video quality, 11/13 (85%) studies concluded the overall video quality as poor.ConclusionsOverall, the educational content quality of YouTube videos evaluated in the literature accessible as an educational resource regarding perioperative anesthesia was poor. While these videos are in demand, their impact on patient and trainee education remains unclear. A standardized methodology for evaluating online videos is merited to improve future reporting. A peer-reviewed approach to online open-access videos is needed to support patient and trainee education in anesthesia.Study registrationOpen Science Framework (https://osf.io/ajse9); first posted, 1 May 2023.