Home

Sensor Review

Publisher:
Emerald Group Publishing Limited
Emerald Publishing
ISSN:
0260-2288
Scimago Journal Rank:
40
journal article
LitStream Collection
A multi-sensor based emergency healthcare monitoring system integrating heart status, stress, and alcohol detections

Kaur, Karandeep; Verma, Harsh Kumar

2023 Sensor Review

doi: 10.1108/sr-03-2022-0136

Ubiquitous health-care monitoring systems can provide continuous surveillance to a person using various sensors, including wearables and implantable and fabric-woven sensors. By assessing the state of many physiological characteristics of the patient’s body, continuous monitoring can assist in preparing for the impending emergency. To address this issue, this study aims to propose a health-care system that integrates the treatment of the impending heart, stress and alcohol emergencies. For this purpose, this study uses readings from sensors used for electrocardiography, heart rate, respiration rate, blood alcohol content percentage and blood pressure of a patient’s body.Design/methodology/approachFor heart status, stress level and alcohol detection, the parametric values obtained from these sensors are preprocessed and further divided into four, five and six phases, respectively. A final integrated emergency stage is derived from the stages that were interpreted to examine at a person’s state of emergency. A thorough analysis of the proposed model is carried out using four classification techniques, including decision trees, support vector machines, k nearest neighbors and ensemble classifiers. For all of the aforementioned detections, four metrics are used to evaluate performance: classification accuracy, precision, recall and fmeasure.FindingsEventually, results are validated against the existing health-care systems. The empirical results received reveal that the proposed model outperforms the existing health-care models in the context of metrics above for different detections taken into consideration.Originality/valueThis study proposes a health-care system capable of performing data processing using wearable sensors. It is of great importance for real-time systems. This study assures the originality of the proposed system.
journal article
LitStream Collection
Comparison of different reinforcement methods on crack monitoring characteristics of eddy current array sensor

Fan, Xianghong; Chen, Tao; He, Yuting

2023 Sensor Review

doi: 10.1108/sr-09-2022-0355

This paper aims to study the influence of different reinforcement methods on crack monitoring characteristics of eddy current array sensors, and the sensors with two different reinforcement methods, SUS304 reinforcement and permalloy reinforcement, are proposed.Design/methodology/approachFirst, the finite element model of the sensor is established to analyze the influence of the reinforcement plate’s electromagnetic parameters on the crack identification sensitivity. Then, the crack monitoring accuracy test of sensors with two reinforcement methods is carried out. Finally, the fatigue crack monitoring experiments with bolt tightening torques of 45 and 63 N · m are carried out, respectively.FindingsIn this study, it is found that the crack identification sensitivity of the sensor can be improved by increasing the relative permeability of the reinforcement plate. The crack monitoring accuracy of the sensors with two different reinforcement methods is about 1 mm. And the crack identification sensitivity of the sensor reinforced by permalloy reinforcement plate is significantly higher than that of the sensor reinforced by SUS304 reinforcement plate.Originality/valueThe sensor reinforced by reinforcement plate can work normally under the squeezing action of the bolt, and the crack monitoring sensitivity of the sensor can be significantly improved by using the reinforcement plate with high relative permeability.
journal article
LitStream Collection
Design a custom resistive force sensors to optimize sensorized insoles

Nascimento, Diego Henrique Antunes; Magalhães, Fabrício Anicio; Sabino, George Schayer; Resende, Renan Alves; Duarte, Maria Lucia Machado; Santos Vimieiro, Claysson Bruno

2023 Sensor Review

doi: 10.1108/sr-08-2022-0322

Currently, several studies have been published using sensorized insoles for estimating ground reaction force using plantar pressure. However, information on design parameters, manufacturing techniques and guidelines for developing insoles is scarce, often leaving gaps that do not allow reproducing the insole. This study aims to empirically investigate the main parameters of constructing a sensorized insole for application in human gait.Design/methodology/approachTwo devices were built to evaluate the force sensors. The first focuses on the construction of the sensors with different settings: the density of the sensor’s conductive trails (thickness and distance of the trails) and the inertia of the sensors (use of spacers to prevent unwanted readings). The second device focuses on the data capture and processing system: resolution of the analog–digital converter, acquisition rate and sensor activation level.FindingsThe resolution increase of the analog–digital converter and acquisition rate do not contribute to noise increase. Reducing the sensors’ coverage area can increase sensorized insole capacity. The inertia of the sensors can be adjusted using spacers without changing the electrical circuit and acquisition system.Originality/valueMost sensorized insoles use commercial sensors. For this reason, it is not possible a full customization. This paper maps the main variables to manufacture custom sensors and data acquisition systems. This work also presents a case study where it is possible to see the influence of the parameters in the correlation between the sensorized insole and an instrumented treadmill with a force platform.
journal article
LitStream Collection
A flexible pressure sensor with interference immunity capability

Liu, Huan; Wang, Rui; Wang, Junyao; Chen, Xingyu; Li, Yunpeng; Cui, Bowen; Lang, Tianhong; Zhu, Weihua

2023 Sensor Review

doi: 10.1108/sr-12-2021-0487

Flexible pressure sensor arrays have promising applications in analog haptics, reconfiguration of sensory functions, artificial intelligence, wearable devices and human-computer interaction. The force disturbance generated by the connecting material between the sensor array units will reduce the detection accuracy of the unit. The purpose of this paper is to propose a flexible pressure sensor with interference immunity capability. A C-type bridge flexible piezoelectric structure is used to improve the pressure perturbation. The interference immunity capability of the sensor has been improved.Design/methodology/approachIn this paper, a C-type pressure sensor array structure by rapid injection moulding is manufactured through the positive piezoelectric effect of a piezoelectric material. The feasibility of C-type interference immunity structure in a flexible sensor array is verified by further analysis and experiment. A flexible pressure sensor array with C-type interference immunity structure has been proposed.FindingsIn this paper, we present the results of the perturbation experiment results of the C-type pressure sensor array, showing that the perturbation error is less than 8%. The test of the flexible sensor array show that the sensor can identify the curved angle of up to 120 °, and the output sensitivity of the sensor in the horizontal state reaches 0.12 V/N, and the sensor can withstand the pressure of 80 N. The flexible sensor can work stably in the stretch rate range of 0–8.6% and the stretch length range of 0–6 mm.Originality/valueIn this paper, C-type pressure sensor array structure is fabricated by rapid injection moulding for the first time. The research in this paper can effectively reduce the disturbance of input pressure on the sensor’s internal array and improve the output accuracy. The sensor can intuitively reflect the number of fingers sliding on the sensor by the order in which the maximum voltage appears. Due to the strong interference immunity capability and flexibility of the flexible sensor array mechanism, it has a broad application prospect in the practical fields of haptic simulation, perceptual function reconstruction, artificial intelligence, wearable devices and human–computer interaction.
journal article
LitStream Collection
Noise measurement and system calibration on magnetoresistive sensors

Dou, Aiyu; Bai, Ru; Zhu, Huachen; Qian, Zhenghong

2023 Sensor Review

doi: 10.1108/sr-07-2022-0284

The noise measurement on magnetoresistive (MR) sensors is generally conducted by techniques including single-channel data sampling and fast Fourier transform (FFT) analysis as well as two-channel cross-correlation. The single-channel method is easy to implement and is widely used in the noise measurement on MR sensors, whereas the two-channel method can only eliminate part of the system noise. This study aims to address two key issues affecting measurement accuracy: calibration of the measurement system and the elimination of system noise.Design/methodology/approachThe system is calibrated by using a low-noise metal film resistor in that the system noise is eliminated through power spectrum subtraction. Noise measurement and analysis are conducted for both thermal noise and detectivity of magnetic tunnel junction (MTJ) sensor.FindingsThe thermal noise measurement error is less than 2%. The detectivity of the MTJ sensor reaches 27 pT/Hz1/2 at 2 kHz.Originality/valueThis study provides a more practical solution for noise measurement and system calibration on MR sensors with a bias voltage and magnetic field.
journal article
LitStream Collection
Research on thermal protection of piezoelectric pressure sensor for shock wave pressure measurement in explosion field

Shi, Yucheng; Kong, Deren; Ma, Xuejiao

2023 Sensor Review

doi: 10.1108/sr-11-2022-0407

The purpose of this study is to clarify the mechanism of ambient and transient temperature effects on piezoelectric pressure sensors, and to propose corresponding compensation measures. The temperature of the explosion field has a significant influence on the piezoelectric sensor used to measure the shock wave pressure. For accurate shock wave pressure measurement, based on the actual piezoelectric pressure sensors used in the explosion field, the effects of ambient and transient temperatures on the sensor should be studied.Design/methodology/approachThe compensation method of the ambient temperature is discussed according to the sensor size and material. The theoretical analysis method of the transient temperature is proposed. For the transient temperature conduction problem of the sensor, the finite element simulation method of structure-temperature coupling is used to solve the temperature distribution of the sensor and the change in the contact force on the quartz crystal surface under the step and triangle temperatures. The simulation results are highly consistent with the theory.FindingsBased on the analysis results, a transient temperature control method is proposed, in which 0.5 mm thick lubricating silicone grease is applied to the sensor diaphragm, and 0.2 mm thick fiberglass cloth is wrapped around the sensor side. Simulation experiments are carried out to verify the feasibility of the control method, and the results show that the control method effectively suppresses the output of the thermal parasitic.Originality/valueThe above thermal protection methods can effectively improve the measurement accuracy of shock wave pressure and provide technical support for the evaluation of the power of explosion damage.
journal article
LitStream Collection
Development of an ultrasonic linear encoder

Chang, Chung-Ping; Hong, Song-Fu; Chen, Tzu-Guang

2023 Sensor Review

doi: 10.1108/sr-07-2022-0262

In this investigation, a linear encoder system based on the ultrasonic transducer has been proposed. Ultrasonic transducers are usually designed for distance measurements, such as the time of flight method and sonar system. These applications are defined as discrete-length measurement technologies. The purpose of this study is to develop a continuous displacement measurement system using ultrasonic transducers.Design/methodology/approachA modified signal processing based on heterodyne signaling is implemented in this system. In the proposed signal processing, there is an automatic gain control module, a phase-shifting module, a phase detection module, an interpolation module and especially a frequency multiplication module, which can enhance the resolution and reduce the interpolation error simultaneously.FindingsThe proposed system can generate the encoding signals and is compatible with most motion control systems. For the experimental result, the maximum measurement error and standard deviation are about −0.027 and 0.048 mm, respectively. It shows that the proposed encoder system has the potential for displacement measurement tasks.Originality/valueThis study reveals an ultrasonic linear encoder that is capable of generating an incremental encoding signal, accompanied by a corresponding signal processing methodology. In contrast to the conventional heterodyne signal processing approach, the proposed multiplication method effectively reduces the interpolation error that arises because of multiple reflections.
Articles per page
Browse All Journals

Related Journals: