A. Schuchert, H. Langen, K. Michels, T. Meinertz (1996)
[Low stimulation impedance in pacemaker patients with cardiac diseases. The Thera Pacemaker Study Group].Deutsche medizinische Wochenschrift, 121 34-35
Edward Chinchoy, Charles Soule, A. Houlton, William Gallagher, Mark Hjelle, T. Laske, Josée Morissette, P. Iaizzo (2000)
Isolated four-chamber working swine heart model.The Annals of thoracic surgery, 70 5
F. Hidden‐Lucet, W. Hartung, K. McTeague, P. Walter, J. Langberg (1996)
Effects of High Energy Shocks on Pacing Impedance During Transvenous ICD ImplantationPacing and Clinical Electrophysiology, 19
D. Danilović, O. Ohm (1998)
Pacing Impedance Variability in Tined Steroid Eluting LeadsPacing and Clinical Electrophysiology, 21
E. Platia, J. Brinker (1986)
Time Course of Transvenous Pacemaker Stimulation Impedance, Capture Threshold, and Electrogram AmplitudePacing and Clinical Electrophysiology, 9
(1975)
Stimulation electrodes
T. Laske, N. Skadsberg, P. Iaizzo (2002)
Comparative in vivo and ex vivo pacing and sensing performance study using isolated four-chamber working swine heart modelProceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology, 2
A. Schuchert, H. Langen, K. Michels, T. Thera-Schrittmacher-Studiengruppe (2008)
Niedrige Stimulationsimpedanz bei Herzschrittmacher-Patienten mit kardialen ErkrankungenDMW, 121
A. Schuchert, R. Cappato, K. Kuck, Thomas Meinertz (1996)
Reliability and Variability of Impedance Measured by Real‐Time TelemetryPacing and Clinical Electrophysiology, 19
G. Benzing, R. Iltis, J. Helmsworth, T. Schreiber, S. Kaplan (1980)
Measurement of the ohmic electrode-tissue contact resistance and the voltage applied to myocardium.Journal of biomedical engineering, 2 1
R. Raymond, K. Nanian (1984)
Insulation Failure with Bipolar Polyurethane Pacing LeadsPacing and Clinical Electrophysiology, 7
G. Tyers, R. Brownlee, H. Hughes, C. Shaffer, E. Williams, R. Kao (1979)
Myocardial stimulation impedance: the effects of electrode, physiological, and stimulus variables.The Annals of thoracic surgery, 27 1
JOACHIM Siegmund, JOHN Wilson, STEPHEN Lattner, Kimberly Granneman, Robert Johnson (1996)
Impedance of Pacemaker Leads: Correlation of Different MethodsPacing and Clinical Electrophysiology, 19
M. Sharif, D. Wyse, J. Rothschild, A. Gillis (1998)
Changes in pacing lead impedance over time predict lead failure.The American journal of cardiology, 82 5
A. Hill, T. Laske, J. Coles, D. Sigg, N. Skadsberg, Sarah Vincent, C. Soule, W. Gallagher, P. Iaizzo (2005)
In vitro studies of human hearts.The Annals of thoracic surgery, 79 1
A. Schuchert, K. Kuck (1993)
Effects of local steroid elution on chronic pacing threshold and impedance of endocardial pacemaker leads.Cardiology, 83 4
Schuchert Schuchert, Van Langen Van Langen, Michels Michels, Meinertz Meinertz (1996)
Low stimulation impedance in pacemaker patients with cardiac diseases. The Thera Pacemaker Study GroupDtsch Med Wochenschr, 121
Laske Laske, Skadsberg Skadsberg, Iaizzo Iaizzo (2002)
Comparative in vivo and ex vivo pacing and sensing performance study using an isolated four‐chamber working swine heart model. (Abstract)IEEE Trans, A.6.1
Background: Variations in measured pacing impedances that occur at the time of lead implantation remain largely unexplained and may be due to the morphology of the tissue‐lead interface. Methods: An endocardial pacing lead was implanted under direct endoscopic visualization and parameters were measured for defined stages of implantation into multiple sites within the right atrium of in vitro swine hearts (n = 6, 38 implants), in vivo swine hearts (n = 2, 10 implants), and an in vitro human heart (n = 1, 15 implants). Results: Steady increases in impedance values up to 2 turns fully fixed (2TF) were associated with minimal tissue distortion in all implants. Overtorquing of the in vitro swine implants resulted in severe distortion at the tissue‐lead interface demonstrating either tissue wrapping (24 implants) or tissue coring (14 implants). Impedance and threshold values remained elevated (953 ± 282 Ω, 7.86 ± 3.0 V; both P < 0.05 vs 2TF) during tissue distortion/wrapping, while tissue‐cored implants were associated with significant decreases (552 ± 187 Ω, 6.2 ± 2.2 V; both P < 0.05 vs 2TF). P‐wave amplitudes demonstrated no significant changes or correlation to tissue distortion. Importantly, both swine in vivo and human in vitro data demonstrated similar trends compared with the swine in vitro data. Conclusions: In this study, one is able to directly observe and correlate the degree of distortion at the tissue‐lead interface with measured electrical parameters. Instantaneous impedance values obtained during fixation serve as a superior indicator of an acceptable lead implantation, and should therefore be carefully monitored during implantation.
Pacing and Clinical Electrophysiology – Wiley
Published: Sep 1, 2005
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.