Filter

  • Advanced Filters:

  • to
  • Specific Data Sources:

    All Edit

    Select All  |  Select None

Reset filters

DeepDyve - Search, Rent, Read
The easiest way for you to get scholarly articles:

  • Millions of articles from over 6,000 authoritative journals.
  • Get any 40 rentable articles for just $40 a month.
  • Read rented articles for an entire year.
  • Unused rentals get rolled over.

Bookmark

The development of a diagnostic reference level on patient dose for CT examination in Korea

Cho, PyongKon; Seo, BoKyung; Choi, TaeKyu; Kim, JangSeob; Kim, YouHyun; Choi, JongHak; Oh, YuWhan; Kim, KiHyun; Kim, SunUng
Radiation Protection Dosimetry , Volume 129 (4): 463 Oxford University PressMay 1, 2008

Preview Only

The development of a diagnostic reference level on patient dose for CT examination in Korea

Abstract

Abstract The purpose of this research is to develop a diagnostic reference level for computed tomography (CT) suitable for Korean medical purposes. The direction of CT application and details on patient dose were investigated by survey, and the dose measurement is targeted in general hospitals registered with the Korean Hospital Association. The dose measurement was done with head and body phantom, and an accurate dosimeter was utilised in medical institutions that participated in the survey. The survey and dose measurements on the patient dose showed that the 75th percentiles in the distribution of weighted CT dose index (CTDIw) were 50.5 and 45.4 mGy for the head and 14.4 and 25.30 mGy for the body portions, respectively. Based on these research data, the target patient doses that are believed to be achievable for CT examination in Korean circumstances are about 48 ± 4 mGy in the head and 20 ± 8 mGy in the body. © The Author 2007. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org
Loading next page...
1 Page

Preview Only. This article cannot be rented because we do not currently have permission from the publisher.

 
/lp/oxford-university-press/the-development-of-a-diagnostic-reference-level-on-patient-dose-for-ct-aJ7kpImFFs
Title
The development of a diagnostic reference level on patient dose for CT examination in Korea
Author(s)
Cho, PyongKon; Seo, BoKyung; Choi, TaeKyu; Kim, JangSeob; Kim, YouHyun; Choi, JongHak; Oh, YuWhan; Kim, KiHyun; Kim, SunUng
Journal
Radiation Protection Dosimetry , Volume 129 (4): 463 Oxford University Press – May 1, 2008
Publisher
Oxford University Press
Copyright
Copyright © 2010 Oxford University Press
ISSN
0144-8420
eISSN
1742-3406
D.O.I.
10.1093/rpd/ncm463
Publisher site
Get PDF