Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

The biological safety of condom material can be determined using an in vitro cell culture system

The biological safety of condom material can be determined using an in vitro cell culture system Latex products have long been recognized as a cause of latex protein allergy. The increased usage of latex gloves, with the consequent increased occurrence of latex allergies appears to have escalated with increasing awareness of the transmission of HIV-AIDS and other infections. The use of condoms as a means to prevent the transmission of STD's (sexually transmitted diseases) and HIV-AIDS has been widely promoted. Although extensive testing is done to evaluate the physical quality of condoms, no information is available regarding the biological safety of condoms. This study was undertaken to determine the effects of short-term exposure to physiological levels of condom surface material on cell viability (MTT assay) and cell growth (crystal violet assay). A direct contact cell culture testing method (FDA test method F813-83 used to evaluate the cytotoxic potential of medical materials and devices) was used. The modified test method was found to be a sensitive test system for the evaluation of the biological safety of condoms. This study reveals the importance of evaluating the biological safety of all condoms that are commercially available, because of the potential health risk that may be associated with prolonged use of certain types of condoms. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Analytical Cellular Pathology IOS Press

The biological safety of condom material can be determined using an in vitro cell culture system

Loading next page...
 
/lp/ios-press/the-biological-safety-of-condom-material-can-be-determined-using-an-in-hZ70mKH00Z

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
IOS Press
Copyright
Copyright © 2001 by IOS Press, Inc
ISSN
0921-8912
eISSN
1878-3651
Publisher site
See Article on Publisher Site

Abstract

Latex products have long been recognized as a cause of latex protein allergy. The increased usage of latex gloves, with the consequent increased occurrence of latex allergies appears to have escalated with increasing awareness of the transmission of HIV-AIDS and other infections. The use of condoms as a means to prevent the transmission of STD's (sexually transmitted diseases) and HIV-AIDS has been widely promoted. Although extensive testing is done to evaluate the physical quality of condoms, no information is available regarding the biological safety of condoms. This study was undertaken to determine the effects of short-term exposure to physiological levels of condom surface material on cell viability (MTT assay) and cell growth (crystal violet assay). A direct contact cell culture testing method (FDA test method F813-83 used to evaluate the cytotoxic potential of medical materials and devices) was used. The modified test method was found to be a sensitive test system for the evaluation of the biological safety of condoms. This study reveals the importance of evaluating the biological safety of all condoms that are commercially available, because of the potential health risk that may be associated with prolonged use of certain types of condoms.

Journal

Analytical Cellular PathologyIOS Press

Published: Jan 1, 2001

There are no references for this article.