Filter

  • Advanced Filters:

  • to
  • Specific Data Sources:

    All Edit

    Select All  |  Select None

Reset filters

DeepDyve - Search, Rent, Read
The easiest way for you to get scholarly articles:

  • Millions of articles from over 6,000 authoritative journals.
  • Get any 40 rentable articles for just $40 a month.
  • Read rented articles for an entire year.
  • Unused rentals get rolled over.

Bookmark

Influence of MLC leaf width on biologically adapted IMRT plans

Rødal, Jan; Søvik, Åste; Malinen, Eirik
Acta Oncologica , Volume 49 (7) Informa HealthcareOct 1, 2010

Preview Only

Influence of MLC leaf width on biologically adapted IMRT plans

Abstract

Introduction . High resolution beam delivery may be required for optimal biology-guided adaptive therapy. In this work, we have studied the influence of multi leaf collimator (MLC) leaf widths on the treatment outcome following adapted IMRT of a hypoxic tumour. Material and methods . Dynamic contrast enhanced MR images of a dog with a spontaneous tumour in the nasal region were used to create a tentative hypoxia map following a previously published procedure. The hypoxia map was used as a basis for generating compartmental gross tumour volumes, which were utilised as planning structures in biologically adapted IMRT. Three different MLCs were employed in inverse treatment planning, with leaf widths of 2.5 mm, 5 mm and 10 mm. The number of treatment beams and the degree of step-and-shoot beam modulation were varied. By optimising the tumour control probability (TCP) function, optimal compartmental doses were derived and used as target doses in the inverse planning. Resulting IMRT dose distributions and dose volume histograms (DVHs) were exported and analysed, giving estimates of TCP and compartmental equivalent uniform doses (EUDs). The impact of patient setup accuracy was simulated. Results . The MLC with the smallest leaf width (2.5 mm) consistently gave the highest TCPs and compartmental EUDs, assuming no setup error. The difference between this MLC and the 5 mm MLC was rather small, while the MLC with 10 mm leaf width gave considerably lower TCPs. When including random and systematic setup errors, errors larger than 5 mm gave only small differences between the MLC types. For setup errors larger than 7 mm no differences were found between non-uniform and uniform dose distributions. Conclusions . Biologically adapted radiotherapy may require MLCs with leaf widths smaller than 10 mm. However, for a high probability of cure it is crucial that accurate patient setup is ensured.
Loading next page...
1 Page

Preview Only. This article cannot be rented because we do not currently have permission from the publisher.

 
/lp/informa-healthcare/influence-of-mlc-leaf-width-on-biologically-adapted-imrt-plans-VpOcqDTIzp
Title
Influence of MLC leaf width on biologically adapted IMRT plans
Author(s)
Rødal, Jan; Søvik, Åste; Malinen, Eirik
Journal
Acta Oncologica , Volume 49 (7) Informa Healthcare – Oct 1, 2010
Publisher
Informa Health
Copyright
© 2010 Informa Healthcare
ISSN
0284-186X
eISSN
1651-226X
D.O.I.
10.3109/0284186X.2010.498832
Publisher site
Get PDF